12.2.2. Maintenance and Inspection
12.2.2.1. Periodic Part Replacement
The unit does not have components that require periodical replacement.
12.2.2.2. Consumables and Durables
Some components may require replacement due to wear, deterioration or damage. Replace them as
required.
12.2.2.2.1. Finisher Unit
No.
Part Name
1
Stapler
12.2.2.2.2. Scheduled Maintenance
Item
Feeding Assembly Roller
Feeding Assembly Member
Paper Path Guide
Transmission Type Sensor
12.2.2.3. Disassembly and Assembly
Ver. 1.1
Part No.
GH03-7811
Interval
Shortest cleaning interval of the
Host machine
Q'ty
Expected Life
1
200,000 operations
Description
Cleaning
<Removing Finisher Cover Assembly>
(1) Open and hold the Finisher Cover (14108).
(2) Release the Front and Rear Arms (14109 and
14110).
(3) Release the Rear Latch and remove the
Finisher Cover (14108).
(4) Remove 1 Screw (14133).
(5) Remove the Front Cover Assembly (14101).
Note:
When re-installing the Cover, make sure 1 Latch
Hook is in the hole and the Release Lever works
correctly.
869
DP-C405/C305/C265
Remarks
A single cartridge
contains 3,000 staples.
Remarks
Wipe with clean cloth
moistened in water.
Wipe with a dry cloth.
FEB 2008