hit counter script

Panasonic DP-C305 Service Manual page 522

Hide thumbs Also See for DP-C305:
Table of Contents

Advertisement

No.
Item
172
Color Reg Entry
173
Paper Full Sensor
174
Mono Color Judge
Invalid
175
Mechanical Counter1 No
176
Mechanical Counter2 No
177
PS Limit Toner
Overlap
178
PS Change CIE-
Color Use
179
Counter Backup
(See section 3.8. for
more details)
180-
Not Used
184
Ver. 1.1
F5 Mode
Selection
Min
Medium
Low
Medium
No
Yes
Yes
Off
Off
On
No (for USA/
BK
Canada)
1C
BK (Others)
BK+1C
2C
BK+1C+2C
4C
2C+4C
1C+2C+4C
Total
No (For USA/
BK
Canada)
1C
1C+2C+4C
BK+1C
(Others)
2C
BK+1C+2C
4C
2C+4C
1C+2C+4C
Total
Off
On
On
No
No
Yes
No
No
Yes
522
Default Setting
Set the frequency of the Color
Registration density control.
Min (occurs most frequent),
Medium (default).
Set whether to activate the Paper
Full Sensor of the Inner Tray.
Set whether to disable Auto
Detection of monochrome or color
original.
Select the color type for the
mechanical counter 1.
Select the color type for the
mechanical counter 2.
Set to limit Toner Overlap in PS
printing.
Recommended to set it 'ON'.
Select the default when not using
"UseCIEColor" command on the
PS command.
Back up the counter logs on the
SD Card.
DP-C405/C305/C265
Remarks
FEB 2008