hit counter script

Power Supply System; Finisher / Saddle Assembly; Protective Mechanism - Panasonic DP-C305 Service Manual

Hide thumbs Also See for DP-C305:
Table of Contents

Advertisement

12.1.2.8. Power Supply System

12.1.2.8.1. Finisher / Saddle Assembly

1. Outline
When the Host Machine is turned on, it supplies the Finisher Controller PCB with two channels of 24
VDC; one is for the motors and clutches, and the other is turned into 5 VDC by the Regulator IC (IC1)
of the Finisher Controller PCB for use by the sensors and ICs on PCBs.
If a punch unit (option) is installed, power is also supplied to the Punch Controller PCB. Some of 24
VDC used to drive motors is cut off when the Joint Switch (MS2), Front Door Switch (MS1), or Stapler
Safety Switch (MS3) is open.
Fig. 2-061 is a block diagram of the power supply system :
Host
Machine

2. Protective Mechanism

A circuit breaker (CB1) is monitored to protect the 24 VDC system sued to drive the motors against
overcurrent. The 24-V system used to drive the Feed Motor (M1), paddle motor (M2), and delivery
motor (M3) is equipped with a fuse that melts in the presence of overcurrent.
12.1.2.8.2. Punch Unit (Option)
1. Outline
When the Host Machine is turned on, the Punch Unit is supplied by the Finisher Controller PCB with
24-V and 5-V power.
The 24-V power is used to drive the motors, while the 5-V power is used by sensors and the ICs on the
Punch Controller PCB.
The 24-V power to the motors will be cut off when the Joint Switch (MS2) or the Front Door Switch
(MS1) of the Finisher Unit is open.
Ver. 1.1
Joint Switch
(MS2)
24VP
Circuit Breaker
(CB1)
Finisher
Controller PCB
(IC1)
24VL
Regulator IC
Fig. 2-064
Front Door Switch
(MS1)
Stapler Safety Switch
(MS3)
Punch Controller PCB
(Puncher Unit; Option)
804
DP-C405/C305/C265
24V
Motor
24V
Motor
24V
Clutch
5V
Sensor
5V
Logic System
FEB 2008