Ver. 1.1
(41) Remove 2 Black Screws (Y29).
(42) Remove the Drive Roller Brush Assembly
(3635).
<Cleaning the Bias Roller, Initial Point Sensor
Roller, Adjustment Roller, and Drive Roller>
(43) Clean the Bias Roller, Initial Point Sensor Roller,
Adjustment Roller, and Drive Roller with a soft
cloth, saturated with isopropyl alcohol, and then
wipe them with a soft dry cloth.
Note:
Before cleaning the Drive Roller, make sure to
remove the Drive Roller Brush Bracket (see the
previous step).
Note:
When replacing the IT Belt, make sure to clean
these Rollers, especially the Bias Roller at the
same time.
(44) Remove the Snap Ring (3613).
(45) Remove the Adjustment Roller (3612).
135