12.1.5.5. Self Diagnosis

12.1.5.5.1. Alarm
1. Finisher / Saddle Unit
Error
Stapler Absent The stapler is not set. Monitored at all times The staple / fold
Stapler Absent The staple cartridge
has run out of
staples.
Mixed Sheets
Sheets of different
sizes are deposited
in the compartment.
Overstocking
The number of
for Stapling
sheets in the
compartment has
exceeded the limit
imposed on stapling.
Stack Tray
The number of
Overstocking
sheets deposited on
the delivery tray has
exceeded the limit
imposed on the tray.
(sheets, sets)
Saddle
Remove the stack
Overstocking
from the bind tray.
More than 10 stacks
are deposited on the
folded stack tray.
Ver. 1.1
Condition
Timing of Detection
Monitored at all times Normal operation will
When a sheet of a
different size is
placed.
When an extra sheet
is placed.
When an extra sheet
is placed.
When an extra sheet
is placed.
Operation
motor (M7) and the
slide motor (M8) will
stop.
continue; however,
operation is subject
to instructions from
the host machine.
The sheet will be
aligned based on
maximum size width
and delivered as a
stack.
The sheets will be
delivered with
stapling.
Normal operation will
continue.
Normal operation will
continue.
Table 5-034
860
DP-C405/C305/C265
Resetting
Set the stapler.
Replace the staple
cartridge; or, set it
correctly.
Remove the sheets
from the delivery tray.
Remove the stack
from the bind tray.