No.
Item
068 OPC2 MTR Half Speed
069 Not Used
070 DEV1 MTR CL STD Speed
071 DEV1 MTR CL Half Speed
072-
Not Used
074
075 DEV2 MTR B/W STD Speed Developer 2 motor standard speed adjustment
076 DEV2 MTR CL STD Speed
077 Not Used
078 DEV2 MTR Half Speed
079 Not Used
080 Feed MTR B/W STD Speed
081 Feed MTR CL STD Speed
082 Not Used
083 Feed MTR Half Speed
084 Not Used
085 IT Motor B/W STD Speed
086 IT Motor CL STD Speed
087 Not Used
088 IT Motor Half Speed
089 Not Used
090 Fuser MTR BK STD Speed
091 Fuser MTR CL STD Speed
092 Not Used
093 Fuser MTR Half Speed
094 Not Used
095 Fuser MTR Half Speed L
096-
Not Used
123
124 Warm UP Timer
Ver. 1.1
F6 Mode
Remarks
OPC 2 motor half of standard speed adjustment
for mixed printouts.
Developer 1 motor standard speed adjustment
for color printouts.
Developer 1 motor half of standard speed
adjustment for color printouts.
for monochrome printouts.
Developer 2 motor half of standard speed
adjustment for color printouts.
Developer 2 motor half of standard speed
adjustment for mixed printouts.
Feed motor standard speed adjustment for
monochrome printouts.
Feed motor standard speed adjustment for color
printouts.
Feed motor half of standard speed adjustment
for mixed printouts.
Intermediate Transfer motor standard speed
adjustment for monochrome printouts.
Intermediate Transfer motor standard speed
adjustment for color printouts.
Intermediate Transfer motor half of standard
speed adjustment for mixed printouts.
Fuser motor standard speed adjustment for
monochrome printouts.
Fuser motor standard speed adjustment for color
printouts.
Fuser motor half of standard speed adjustment
for mixed printouts.
Fuser motor L half of standard speed adjustment.
Warm up timer adjustment.
When temperature is low, rotates fuser for warm
up. If 1st print in the morning is not fusing
correctly, extend the warm up time.
value increases -> time is extended
527
DP-C405/C305/C265
Setting Range
-99 ~ +99
0.05%
-99 ~ +99
0.10%
-99 ~ +99
0.10%
-99 ~ +99
0.10%
-99 ~ +99
0.10%
-99 ~ +99
0.10%
-50 ~ +50
0.10 %
-50 ~ +50
0.10 %
-50 ~ +50
0.10 %
-99 ~ +99
0.05%
-99 ~ +99
0.05%
-99 ~ +99
0.05%
-99 ~ +99
0.10%
-99 ~ +99
0.10%
-99 ~ +99
0.10%
-99 ~ +99
0.10%
-20 ~ +20
1sec.