Order Number: PMCD031201T8 Digital Cellular Phone EB-X70 Subject : Baseband Calibration Procedure 1 Introduction Please replace Pages 55 and 56 of the X70 Service Manual with the new pages attached to this Technical Bulletin. WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public.
CALIBRATION PROCEDURES 9.4. Battery Calibration 9.4.1 Preliminaries Connect the RF Adaptor / Baseband Jig, telephone and PC as shown in the diagram below. +3.7V POWER SUPPLY CABLE 1 PCB REPAIR JIG +5.8 V POWER SUPPLY CABLE 2 10766-1 Figure 9.3: Battery calibration test connections With the CB2000 software running, select the ‘Baseband Calibration’...
Page 4
CALIBRATION PROCEDURES 9.4.4 Charging Calibration Switch on PSU2 and set the voltage to 5.8 V. Connect Cable 2 to the connector of Cable 1. Carry out the instructions described in the main dialogue window. When prompted, measure the RF Adaptor / Baseband Jig voltage by connecting a voltmeter to the terminals on the RF Adaptor / Baseband Jig.