■ Counter reset: CTR
Resets the current counter value to the initial value.
Counter reset
STX
CTR
Data length
Name
Counter 0
Counter 1
Counter 2
Counter 3
Counter 4
Counter 5
Counter 6
Counter 7
■ Expiry date/time condition: LMT
Sets the expiry date/time condition.
Expiry date/time can be set within the range from January 1, 1980 to December 31, 2099.
Setting / Readout data of expiry date/time condition
STX
LMT
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request of expiry date/time condition
STX
LMT
Data length
Name
[byte]
Expiry No.
1
Expiry
4
Reference unit
1
Start date
1
52
[Counter 0 to 7]
S
8-byte
Description
[byte]
1
1
1
1
"0": Reset OFF
"1": Reset ON
1
1
1
1
Sub
[Expiry No.] [Expiry] [Reference unit] [Start date]
[Expiry No.]
R
1-byte
Description
"1"–"8"
"-999"–"+999"
"0": Year
"1": Month
"2": Day
"3": Hour
"4": Minute
"0": Today not included
"1": Today included
(Check sum)
Delimiter
Counter 4 to counter 7 are common counters.
7-byte
(Check sum)
Delimiter
"5"–"8": common expiry date/time
Possible to be set only when the reference
unit is set to "year" or "month". Indicating if
the date of "today" is included or not.
ME-LPMSZ-SR-9
Remarks
(Check sum)
Delimiter
Remarks