■ Low power detect level: PWL
[Supported models: LP-M5xx/LP-M2xx/LP-Sxxx/LP-SxxxW]
Sets thresholds for determination of whether the result of the power measurement or the power check is in the normal
range.
Setting / Readout data the low power detect level
Sub
STX
PWL
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request out low power detect level
STX
PWL
R
Name
Low power detect level
Reference
• The setting changed by this command is saved without overwriting.
■ Marking energy indicating: MEM
[Supported models: LP-Mxxx/LP-Sxxx]
Displays the measurement results of marking energy [mJ] and time on the setting screen when Test marking is finished.
Setting / Readout data the marking energy indicating
Sub
STX
MEM
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request out marking energy indicating
STX
MEM
R
Name
Marking energy indicating
Reference
• Under the remote mode, the measurement results do not appear on the screen. If the "Marking status transmission
permission (MST command)" is set to "Transmission permitted", the measurement results of the marking energy are
transmitted after the marking operation.
• The setting changed by this command is saved without overwriting.
[Low power detect level]
2-byte
(Check sum)
Delimiter
Data length
Description
[byte]
2
"00"–"99" [%]
[Marking energy indicating]
1-byte
(Check sum)
Delimiter
Data length
Description
[byte]
"0": OFF
1
"1": ON
ME-LPMSZ-SR-9
(Check sum)
Delimiter
Remarks
When "00" is set, the detection is disabled.
(Check sum)
Delimiter
Remarks
Specifies whether the display of the measurement
results of marking energy and time after Test
Marking is enabled.
109