hit counter script

Dip Switch Setting - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

1-2-1 DIP switch setting

Set the operational options for the external control with the DIP switch equipped on the controller rear side.
Reference
• The initial setting of all DIP switches is OFF.
• Turn OFF the power at DIP switch setting.
• For the details on DIP switch, refer to "Safety / Setup / Maintenance Guide".
1.
Turn OFF the power of laser marker.
2.
Remove the DIP switch cover on the rear of the controller.
3.
With DIP switch No. 2, select the control method, I/O or command
for some specific operations.
DIP switch No. 2
ON
OFF (initial setting)
Reference
• "Laser check radiation", "Laser power measurement", "Power check" and "Test marking" cannot be controlled by I/O.
They can be controlled only by using serial communication in the remote mode.
12
ON
OFF
Control method for specific operations
Control by serial communication commands for the
following operations
• Laser pumping (LSR)
• Shutter control (SHT)
• Guide laser (GID)
• Laser check radiation (SPT)
• Laser power measurement (PWM)
• Power check (PWR)
• Test marking (TST)
Control by I/O for the following operations
• Laser pumping
• Shutter control
• Guide laser
ME-LPMSZ-SR-9
DIP switch
Rear of controller

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents