■ Arbitrary point radiation condition: PRF
Sets X/Y coordinate offset and laser power correction ratio, etc. for the specified arbitrary point radiation condition.
Setting / Readout data of general condition
Sub
STX
PRF
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request of processing condition
STX
PRF
R
Data length
Name
[byte]
Point radiation
condition No.
Layer No.
X offset
Y offset
Laser power
correction
(Laser pulse cycle
correction)
* For the detail of the model type, refer to "Target laser marker" (P.4).
[Point radiation condition No.] [Layer No.] [X offset]
[Y offset] [Laser power correction]
[Laser pulse cycle correction]
26-byte (LP-Mxxx / LP-Sxxx / LP-Zxxx), 23-byte (LP-SxxxW)
[Point radiation condition No.]
2-byte
2
"00"–"15"
2
"00"
Model type*
8
LP-Sxx0(W)
LP-Sxx5(W)
LP-Sxx2
LP-Mxx0/LP-Zxx0 "-060.000"–"+060.000"
8
LP-Mxx5
LP-Mxx6/LP-Zxx6
3
"000"–"999" [%]
(3)
"001"–"999" [%]
(Check sum)
Description
Setting range [mm]
"-045.000"–"+045.000"
"-080.000"–"+080.000"
"-027.500"–"+027.500"
"-110.000"–"+110.000"
"-165.000"–"+165.000"
ME-LPMSZ-SR-9
(Check
Delimiter
sum)
Delimiter
Remarks
Fixed value
• The correction ratio is calculated
using the value set at the laser
condition as 100%.
• With LP-SxxxW type, nothing
should be input in Laser Pulse
Cycle Correction.
79