■ Lot condition: LTC
Sets the condition of "Lot Function" to change characters depending on date/time and counter values.
Setting / Readout data of lot condition
Sub
STX
LTC
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request of lot condition
STX
LTC
R
Data length
Name
[byte]
Lot No.
1
Lot target
2
Period unit
1
Reference
• When the period unit of the lot condition (LTC command) is changed, the lot period and lot character (LTS command)
settings registered to that lot number are deleted.
[Lot No.] [Lot target] [Period unit]
4-byte
[Lot No.]
1-byte
Description
"0"–"7"
"00": Current
"01"–"08": expiry 1 to 8
"10"–"17": counter 0 to 7
"0": Year or counter
"1": Month
"2": Day
"3": Y/M
"4": M/D
"5": Day of week
"6": Hour
"7": Week
"8": Minute
"9": Hour/Min.
"A": Week-based year
ME-LPMSZ-SR-9
(Check sum)
(Check sum)
Delimiter
"4"–"7": common lot
The unit of period to switch the character string
for marking is indicated.
Delimiter
Remarks
53