Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Electrical
Instructions
Shock
Hazard
This product is only suitable for well insulated areas or occasional use.
1. SAFETY
1.1.
Electrical Safety
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey dealer.
if the lamp is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance
Test) tested.
Electrical safety information, it is important that the following information is read and understood.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
9
regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
9
Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
9
correct fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a
8
qualified electrician.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
9
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
General
WARNING! Disconnect the heater from the mains power supply before carrying out any servicing or
maintenance.
Maintain the heater in good order and clean condition for best and safest performance. Replace or repair
9
damaged parts.
Locate heater in a suitable work area and keep area clean, tidy and free from unrelated materials. Ensure there is adequate
9
lighting and keep the immediate area in front of the outlet grille clear.
Allow the unit to cool before storage. When not in use, disconnect from the mains power supply and store in a safe, cool, dry,
9
childproof area.
Only use the heater standing in the upright position on a level surface.
9
DO NOT use the heater where there are flammable liquids, solids or gases such as petrol, solvents, aerosols etc, or where heat sensitive materials
8
may be stored.
DO NOT place the heater near items that may be damaged by heat, allow at least 2mtr clearance in front of the heater.
8
DO NOT allow the heater to get wet as this may cause an electric shock, causing damage to the heater and possible personal
injury.
DO NOT let power lead hang over an edge (i.e. table), or touch a hot surface, lie in the beam of heat, or run under a carpet.
8
DO NOT use in bathroom, shower room, or in any wet or damp environments or where there is high condensation.
8
DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT insert or allow objects to enter any openings of heater as this may cause an electric shock, fire or damage to heater.
8
DO NOT use heater if the power cord, plug or the heater is damaged, or if the heater has become wet.
8
DO NOT use the heater for any purpose other than for which it is designed.
8
DO NOT use a timer or other remote device to operate the heater.
8
DO NOT allow children to touch or to operate the heater.
8
DO NOT site the heater below an electrical socket outlet.
8
© Jack Sealey Limited
INSTRUCTIONS FOR
INDUSTRIAL PTC FAN HEATER 2000W/230V
MODEL NO:
Hot Surfaces
Do Not Cover
Original Language Version
PEH2001
Recommended fuse rating
13 Amp
PEH2001 | Issue 2(ERP) 21/06/18

Advertisement

loading

Summary of Contents for Sealey PEH2001

  • Page 1 PEH2001 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...
  • Page 3 Room temperature control, with open window detection With distance control option With adaptive start control With working time limitation With black bulb sensor Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk ERP Table 2...

This manual is also suitable for:

Peh2001.v1