Southern Series Woodburners - Lewis, Lindis, McKenzie
Installation Instructions
Note: Flue System Casing
Flue system may require to be double lined to comply. Ref ASNZS:2918:2001 4.3 Flue pipe casing
Visit
www.warmington.co.nz
for specs, DWGs and PDF uploads of fires
Fire, flue system and instructions to comply with ASNZS 2918:2001 & Building Code C/AS1 7.5 Open Fires
Keep these instructions for further reference. Ensure that you have the correct and current installation details for the Warmington Fire.
Installation
The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician.
IMPORTANT
Read all the instructions carefully before commencing the installation. Failure to follow these instructions may result in a fire hazard and void the warranty.
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
Traditional brick built open gas fire & gas burner (28 pages)
Summary of Contents for Warmington Southern Series
Page 1
DWGs and PDF uploads of fires Fire, flue system and instructions to comply with ASNZS 2918:2001 & Building Code C/AS1 7.5 Open Fires Keep these instructions for further reference. Ensure that you have the correct and current installation details for the Warmington Fire. Installation The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician.
Page 2
When Tested in Accordance with AS/NZS 4012 Performance may vary from tested values depending on actual operating conditions. Date of installation: _____/_____/20_____ Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm Copyright...
Double Skin The Southern Series firebox is a radiant/ convection stove. It has an inner and outer skin whereby room air flows between the surfaces, thus becoming hot and efficiently heating the room. A convection air plenum is positioned on the rear of the firebox which is directed through a duct across the top of the heater moving hot air through the room.
If there is a lot of charcoal you may be turning the combustion air down to soon after refueling, or not raking the charcoal to the combustion air inlet, or turning the combustion air down too low to support efficient combustion, or all of the above. Warmington wood- burning appliances work best when a small amount of ash is left approximately 25mm deep in the firebox after cleaning, this aids with stable burning.
Holding Down Brackets Check Door Seal Check Damper Bricks (If Required) Serial Number Check Loading Badge Packed By Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm Copyright...
The Southern Series requires a “ASH ONLY” floor protector as needed for some types of wood burners. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm...
To flue centre * Measurement taken from front ash lip ** Measurement taken from flue centre sides Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm Copyright...
Page 8
Install in accordance with AS3500.4.1 or NZS4603 and the appropriate requirements of the relevant building code or codes. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm...
Page 9
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm Copyright...
Page 10
Attach S/S Reflector to brackets, ensure that the plastic coating is removed from all the surfaces before lighting the fire. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm...
Page 11
All external air vents & ceiling penetrations must be bird proofed with permanently fixed screens. All flashing to comply with E2. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm Copyright...
Page 12
CAUTION: CRACKED AND BROKEN COMPONENTS e.g. GLASS PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION UNSAFE. Industries 1994 LTD PO Box 58652, Botany 2163, Auckland Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All dimensions are in mm Copyright...