hit counter script

Canon imageRUNNER 7095 Service Manual page 68

Hide thumbs Also See for imageRUNNER 7095:
Table of Contents

Advertisement

18) Tighten the screw (flat-head; M4X10) [1]
from behind the arm unit.
F-2-78
19) Tighten the screw (W sems; M4X10) [1] from
behind the control panel.
F-2-79
20) Fix the control panel interface cable [1] in
place using the 2 edge saddles [2] and the wire
saddle [3]; then, connect the connector [4] to
the control panel.
[4]
F-2-80
[1]
[1]
[3]
[2]
[1]
Be sure to adjust the length of the cable [1] so that
it is inside the plate [2].
[2]
[1]
F-2-81
MEMO:
If the control panel is tilting, go through the fol-
lowing steps to correct:
1) Loosen the 4 screws [1] found on the back of
the control panel.
2) Shift the control panel [2] to its correct
orientation, and tighten the screws loosened
previously.
[2]
F-2-82
21) Peel off the protective sheet of the arm cover
4.
22) Mount the arm cover 4 [1] from behind the
arm unit.
- screw (binding; M4X10) [2]
[2]
F-2-83
Chapter 2
[2]
[1]
[1]
[1]