Canon imageRUNNER 7095 Service Manual page 505

Hide thumbs Also See for imageRUNNER 7095:
Table of Contents

Advertisement

<HV-TR>
Sub item
Notes:
At times, the indicated value for the fogging items may differ before and after input (maximum of +/-3). The
fact has to do with the way indicated values are computed, and will not affect the operation of the machine.
TR-N1
Use it to enter the output adjustment value of the transfer charging current. (simplex mode,
plain paper; or 1st side of double-sided print)
range: -650 to 0
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
TR-N2
Use it to enter the output adjustment value of the transfer charging current. (plain paper, 2nd
side of double-sided print)
range: -650 to 0
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
PRE-TR
Use it to enter the output adjustment value of the pre-transfer charging current.
range: 0 to 300
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
HVT-TR
Use it to enter the offset value of the transfer high-voltage output for the high-voltage unit.
range: -100 to 100
Be sure to enter the value indicated on the label attached to the new unit if you have replace
the high-voltage unit.
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
H-PRE-TR Use it to enter the offset voltage of the pre-transfer output for the high-voltage unit.
range: -100 to 100
Be sure to enter the value indicated on the label attached to the new unit if you have replace
the high-voltage unit.
Be sure to enter the value indicated on the service label if you have replaced the DC
controller PCB or initialized the RAM.
D-PRE-TR Use it to enter the offset value of the pre-transfer high-voltage output or the DC controller
PCB.
range: -100 to 100
Be sure to enter the value indicated on the label attached to the new PCB if you have
replaced the DC controller PCB.
Be sure to enter the value indicated on the service label if you have initialized the RAM on
the DC controller PCB.
D-HV-TR
Use it to enter the offset value of the transfer high-voltage output for the DC controller PCB.
range: -100 to 100
Be sure to enter the value indicated on the label attached to the new PCB if you have
replaced the DC controller PCB.
Be sure to enter the value indicated on the service label if you have initialized the RAM on
the DC controller PCB.
T-17-25
COPIER > ADJUST > HV-TR
Description
Chapter 17
Level
1
1
1
1
1
1
1
17-43