3-2.
INITIALIZATION OF C, D PAGE DATA
1. Initializing the C Page Data
Note: If the page C data is initialized, the following adjustments must be
performed again.
1) Modification of C page data
2) Servo and RF system adjustment
Adjusting page
C
Adjusting Address
00 to DF
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 80, set data: 0C, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 80, and check that the data is "1C".
4)
Perform "Modification of C Page Data".
2. Modification of C Page Data
If the C page data has been initialized, change the data of the "Fixed
data-2" address shown in the following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing After Modifying Data
1)
Select page: 2, address: 00, set data: 29, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 2, address: 01, set data: 29, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 0, address: 01, and set data: 00.
4)
Perform "3-4. Servo and RF System Adjustment".
3. C Page Table
Note: Fixed data-1 : Initialized data ( Refer to "1. Initializing the D Page
Data".)
Fixed data-2 : Modified data (Refer to "2. Modification of D Page
Data".)
Initial value
Address
NTSC PAL
00
Fixed data-1
01
(Initialized data)
02
03
04
05
06
07
08
09
0A
0B
0C
Remark
5-29
Initial value
Address
NTSC
PAL
0D
Fixed data-1
0E
(Initialized data)
0F
10
EE
EE
Switching position adj.
11
00
00
12
EE
EE
13
00
00
14
Fixed data-1
15
16
E0
E0
Cap FG duty adj.
17
E0
E0
T reel FG duty adj.
18
2A
2A
AEQ adj.
19
2A
2A
1A
Fixed data-1
1B
33
33
AEQ adj.
1C
33
33
1D
Fixed data-1
1E
25
25
AGC center level adj.
1F
3E
3E
PLL fo adj.
20
3E
3E
21
DC
DC
APC adj.
22
99
99
LPF fo adj.
23
Fixed data-1
24
25
88
88
Line out Y level adj.
26
E3
E3
Line out Cr level adj.
27
A1
A1
Line out Cb level adj.
28
Fixed data-1
29
2A
2B
04
04
Chroma BPF adj.
2C
Fixed data-2
2D
(Modified data, copy the data built in
2E
the same model.)
2F
30
31
32
Fixed data-1
33
(Initialized data)
34
35
36
37
38
00
00
Emergency memory address
39
00
00
3A
00
00
3B
00
00
3C
00
00
3D
00
00
3E
00
00
3F
00
00
40
00
00
41
00
00
42
00
00
43
00
00
44
Fixed data-1
Remark