9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart (Color bar chart standard
picture frame)
Measurement Point
DDS display of LCD or monitor TV
Measuring Instrument
(Note)
Adjustment Page
F
Adjustment Address
2C
Specified Value
78 to 88
Note: The right two digits of the display data of the LCD or monitor TV is
the object data. If the data change so swiftly that it cannot be read
out, record the data on a tape once and play the tape back in the
frame still mode and obtain the average data.
CAM 00 0000
CAM 00 00XX
Switch setting:
1)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: 6, address: 04, and set data: 01.
4)
Select page: 6, address: 40, and set data: 02.
5)
Select page: 6, address: 10, and set data: 02.
6)
Select page: 6, address: 01, set data: 19 and press the PAUSE
button of the adjustment remote commander.
7)
Select page: F, address: 2C, change the data and adjust the DDS
display data to the specified value. (Note)
8)
Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
4)
Select page: 6, address: 04, and set data: 00.
5)
Select page: 6, address: 40, and set data: 00.
6)
Select page: 6, address: 10, and set data: 00.
Object data
10. Auto White Balance & LV Standard Data Input
Subject
Adjustment Page
Adjustment Address
Note 1: Perform "Color Reproduction Adjustment" before this adjustment.
Note 2: Check that the data of page: 6, address: 02 is 00. (If the data is
"01", turn the power of the unit OFF/ON.)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Wait for two seconds.
3)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 01, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
(When the standard data is take in, the data will be automatically
input to address: 20 to 23, 3E, 3F.)
5)
Select page: 6, address: 02, and check that the data is "01".
6)
Perform "Auto White Balance Adjustment".
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
5-15
Clear chart (Color bar chart standard
picture frame)
F
20 to 23, 3E, 3F