Figure 41. Removing and installing a non-redundant power supply
1.
power supply
3.
P1 cable connector
5.
P3 cable connector
7.
Backplane connector

Installing a non-redundant power supply

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1.
Ensure that you read the
2.
Follow the procedure listed in
NOTE: A hot-swappable non-redundant power supply must be installed in Slot 1 of the power
supply bay.
Steps
1.
Align the screw hole on the power supply with the standoff on the chassis.
2.
Tighten the screw to secure the power supply to the chassis.
3.
Connect all the power cables to the system board, hard drives, and optical drive.
Safety
instructions.
Before working inside your
2.
screw
4.
P2 cable connector
6.
standoff
system.