Contents 1 About your system....................8 ..................... 8 Front-panel features and indicators ..........................14 LCD panel features ..........................15 Home screen ............................15 Setup menu ............................. 15 View menu ...........................16 Diagnostic indicators ..................17 Hot swappable hard drive indicator codes ....................18 Back-panel features and indicators ..........................
Page 4
...........................43 About Boot Manager ........................ 43 Entering Boot Manager ......................43 Boot Manager main menu ......................44 About Dell Lifecycle Controller ........................44 Changing the boot order ...................... 44 Choosing the system boot mode ....................45 Assigning a system and setup password ................
Page 5
................... 68 Installing a 3.5 inch hard-drive blank ...................... 68 Removing a cabled hard drive ......................69 Installing a cabled hard drive ....................70 Removing a hot-swap hard drive ....................71 Installing a hot-swap hard drive ..........72 Installing a 2.5 inch hard drive into a 3.5 inch hard-drive adapter ..........
Page 6
........................96 Removing a processor ........................99 Installing a processor .........................102 Installing the heat sink ..........................103 Power supplies ........................104 Hot spare feature ..................104 Removing a redundant power supply ..................105 Installing a redundant power supply ................106 Removing a non-redundant power supply ..................
Page 7
When to use the Embedded System Diagnostics ........... 146 Running the Embedded System Diagnostics from Boot Manager ....146 Running the Embedded System Diagnostics from the Dell Lifecycle Controller ......................147 System diagnostic controls 7 Jumpers and connectors................148 ......................148 System board jumper settings .........................149...
About your system The Dell PowerEdge R430 is a rack server that supports up to two processors based on the Intel Xeon EP E5-2600 v3 family, up to 12 DIMMs, and up to ten hard drives or SSDs. The R430 systems are available in the following configurations: Table 1.
Page 9
USB regular USB port or provide access to the iDRAC port features. For more information, see the Integrated Dell Remote Access Controller User’s Guide at Dell.com/idracmanuals. USB connector Allows you to connect USB devices to the system. The port is USB 2.0-compliant.
Item Indicator, Button, or Icon Description Connector Information tag A slide-out label panel which contains system information such as Service Tag, NIC, MAC address, and so on for your reference. Hard drives Up to four 3.5 inch hot-swappable hard drives or SSDs.
Page 11
USB regular USB port or provide access to the iDRAC port features. For more information, see the Integrated Dell Remote Access Controller User’s Guide at Dell.com/idracmanuals. USB connector Allows you to connect USB devices to the system.
Page 12
USB regular USB port or provide access to the iDRAC port features. For more information, see the Integrated Dell Remote Access Controller User’s Guide at Dell.com/idracmanuals. Diagnostic indicator The diagnostic indicator lights up to display error status. For more information, see Diagnostic indicators.
Page 13
Figure 4. Front-panel features and indicators—four 3.5 inch cabled hard-drive chassis Table 5. Front panel features and indicators of four 3.5-inch cabled hard-drive Item Indicator, Button, or Icon Description Connector Power-on indicator, The power-on indicator lights when the system power button power is on.
The system's LCD panel provides system information and status and error messages to indicate if the system is operating correctly or if the system needs attention. For more information on error messages, see the Dell Event and Error Messages Reference Guide at Dell.com/openmanagemanuals >OpenManage software.
SEL. This is useful when trying to match an LCD message with an SEL entry. Select Simple to view LCD error messages in a simplified user-friendly description. For more information about error messages, see the Dell Event and Error Messages Reference Guide at Dell.com/openmanagemanuals > OpenManage software. Set home Select the default information to be displayed on the Home screen.
For more in standby, and if any error information about error messages, see the exists (for example, a failed Dell Event and Error Messages Reference fan or hard drive). Guide at Dell.com/openmanagemanuals > OpenManage software.
Icon Description Condition Corrective action voltage out of range, or a on the PSU. Reseat the PSU. If the problem failed power supply unit persists, see Getting help. (PSU) or voltage regulator). Temperature The indicator flashes amber Ensure that none of the following indicator if the system experiences a conditions exist:...
NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does not function and remains OFF. Table 8. Hot swappable hard drive indicators Drive-status indicator pattern (RAID only) Condition Flashes green two times per second Identifying drive or preparing for removal.
Page 19
Item Indicator, Button, or Icon Description Connector vFlash card slot Allows you to connect the vFlash card. (optional) iDRAC port (optional) Dedicated management port on the iDRAC ports card. PCIe expansion card Allows you to connect a PCI Express expansion slots (2) card.
Item Indicator, Button, or Icon Description Connector NOTE: For non- redundant power supply units, there is only one power supply socket. NIC indicator codes Figure 8. NIC indicators link indicator activity indicator Table 10. NIC indicators Convention Indicator pattern Description Link and activity indicators The NIC is not connected to the network.
Page 21
NOTE: For AC PSUs, use only PSUs with the Extended Power Performance (EPP) label on the back. Mixing PSUs from previous generations of Dell PowerEdge servers can result in a PSU mismatch condition or failure to turn on. Flashing amber...
Convention Power Indicator Condition Pattern CAUTION: When correcting a PSU mismatch, replace only the PSU with the flashing indicator. Swapping the other PSU to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to a Low Output configuration or vice versa, you must turn off the system.
Quick Resource Locator (QRL) Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting dell.com/QRL or by using your smartphone or tablet and a model...
Page 24
Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR code, scan the following image. Figure 11. Quick Resource Locator...
Turn the system on by pressing the power button or using iDRAC. Turn on the attached peripherals. Setting up and configuring the iDRAC IP address You can set up the Integrated Dell Remote Access Controller (iDRAC) IP address by using one of the following interfaces: •...
For more information, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals. You can also remotely monitor and manage the server by using the Dell OpenManage Server Administrator (OMSA) software and OpenManage Essentials (OME) systems management console. For more information, see dell.com/openmanagemanuals.
Page 27
Download the drivers you require to a diskette drive, USB drive, CD, or DVD.
• System Setup • Boot Manager • Dell Lifecycle Controller Navigation keys The navigation keys can help you quickly access the pre-operating system management applications. Description Enables you to enter System Setup. Enables you to enter system services and starts Lifecycle Controller.
UEFI. You can enable or disable various iDRAC parameters by using the iDRAC settings utility. For more information about this utility, see Integrated Dell Remote Access Controller User’s Guide at Dell.com/idracmanuals. Device Settings Enables you to configure device settings.
Option Description Processor Settings Displays information and options related to the processor such as speed, cache size. SATA Settings Displays options to enable or disable the integrated SATA controller and ports. Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS boot settings.
Option Description UEFI Compliance Displays the UEFI compliance level of the system firmware. Version Memory Settings screen You can use the Memory Settings screen to view all the memory settings as well as enable or disable specific memory functions such as system memory testing and node interleaving. To view the Memory Setting screen, click System Setup Main Menu →...
Page 32
Option Description logical processor per core. By default, the Logical Processor option is set to Enabled. Alternate RTID Enables you to allocate more RTIDs to the remote socket, thereby increasing (Requestor cache performance between the sockets or easing work in normal mode for Transaction ID) NUMA.
Option Description Logical Processor Enables or disables the operating system capability to put logical processors in the Idling idling state in order to reduce power consumption. By default, the option is set to Disabled. Configurable TDP Allows reconfiguration of Thermal Design Power (TDP) to lower levels. TDP refers to the maximum amount of power the cooling system is required to dissipate.
Page 34
Option Description Port A Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS support. For AHCI or RAID mode, BIOS support is always enabled. Option Description Model...
Page 35
Option Description Option Description Capacity Displays the total capacity of the hard drive. This field is undefined for removable media devices such as optical drives. Port E Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS support.
Option Description For AHCI or RAID mode, BIOS support is always enabled. Option Description Model Displays the drive model of the selected device. Drive Type Displays the type of drive attached to the SATA port. Capacity Displays the total capacity of the hard drive. This field is undefined for removable media devices such as optical drives.
Option Description CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not installed in the same boot mode. If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems.
Page 38
Option Description mouse operates during boot process in certain operating systems. After the boot process is complete, the USB keyboard and mouse do not work if the ports are disabled. NOTE: Selecting Only Back Ports On and All Ports Off disables the USB management port and also restricts access to iDRAC features.
Serial Communication screen details You can use the Serial Communication screen to view the properties of the serial communication port. To view the Serial Communication screen, click System Setup Main Menu → System BIOS → Serial Communication. The Serial Communication screen details are explained as follows: Option Description Serial...
Page 40
Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. This option is set to Performance Per Watt Optimized (DAPC) by default. DAPC is Dell Active Power Controller.
Option Description Monitor/Mwait Enables the Monitor/Mwait instructions in the processor. This option is set to Enabled for all system profiles, except Custom by default. NOTE: This option can be disabled only if the C States option in the Custom mode is set to disabled. NOTE: When C States is set to Enabled in the Custom mode, changing the Monitor/Mwait setting does not impact the system power or performance.
Option Description User Defined Sets the User Defined Delay option when the User Defined option for AC Power Delay (60s to Recovery Delay is selected. 240s) UEFI Variable Provides varying degrees of securing UEFI variables. When set to Standard (the Access default), UEFI variables are accessible in the operating system per the UEFI specification.
Option Description Keyboard Enables you to set whether the system boots with the NumLock enabled or NumLock disabled. This option is set to On by default. NOTE: This option does not apply to 84-key keyboards. F1/F2 Prompt on Enables or disables the F1/F2 prompt on error. This option is set to Enabled by Error default.
Launches System Utilities menu such as System Diagnostics and UEFI shell. About Dell Lifecycle Controller Dell Lifecycle Controller allows you to perform useful tasks such as configuring BIOS and hardware settings, deploying an operating system, updating drivers, changing RAID settings, and saving hardware profiles.
NOTE: For the latest information on supported operating systems, go to dell.com/ossupport . Assigning a system and setup password Prerequisites You can assign a new System Password and Setup Password or change an existing System Password and Setup Password only when the password jumper setting is enabled and Password Status is Unlocked.
Steps Turn on or reboot your system. Type your password and press <Enter>. Next steps When Password Status is Locked, type the password and press <Enter> when prompted at reboot. If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password.
NOTE: Accessing some of the features on the iDRAC Settings utility requires the iDRAC Enterprise License upgrade. For more information on using iDRAC, see the iDRAC User's Guide at dell.com/esmmanuals. Entering the iDRAC Settings utility Turn on or restart the managed system.
Page 48
Set the Maximum Air Exhaust Temperature or the Fan Speed Offset fields. Click Back → Finish → Yes.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
After working inside your system Install the system cover. If applicable, install the front bezel. Reconnect the system to its electrical outlet. Turn the system on, including any attached peripherals. Related Tasks Installing the optional front bezel Installing the system cover Recommended tools You may need the following items to perform the procedures in this section: •...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Removing the system cover Prerequisites Ensure that you follow the Safety instructions. Turn off the system, including any attached peripherals. Disconnect the system from the electrical outlet and peripherals. If installed, remove the front bezel. Steps Turn the latch release lock to the unlock position. Lift the latch and rotate the latch toward the back of the system.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 54
Figure 14. Inside the system—with a non-redundant power supply control panel cable routing latch power supply unit expansion-card riser connector (2) memory-module socket (B3, B4) processor 2 memory-module socket (B1, B2) memory-module socket (A1, A5, A2, A6) processor 1 memory-module socket (A3, A7, A4, A8) cooling fan (5) optical drive (optional)
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 58
Figure 17. System memory board Memory channels are organized as follows: Processor 1 channel 0: memory sockets A1 and A5 channel 1: memory sockets A2 and A6 channel 2: memory sockets A3 and A7 channel 3: memory sockets A4 and A8 Processor 2 channel 0: memory sockets B1 channel 1: memory sockets B2...
channel 3: memory sockets B4 The following table shows the memory populations and operating frequencies for the supported configurations. Table 14. Supported configurations DIMM Type DIMMs Populated/ Operating Frequency (in Maximum DIMM Rank/Channel Channel MT/s) 1.2 V RDIMM 2133, 1866, 1600, 1333 Dual rank or single rank 2133, 1866, 1600, 1333 Dual rank or single rank...
Advanced ECC (lockstep) Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This protects against single DRAM chip failures during normal operation. Memory installation guidelines: • Memory modules must be identical in size, speed, and technology. •...
Page 61
System DIMM Size Number of DIMM Rank, DIMM Slot Population Capacity (in (in GB) DIMMs Organization, and Frequency 1R, x8, 2133 MT/s, A1, A2, A3, A4 1R, x8, 1866 MT/s 2R, x8, 2133 MT/s, A1, A2 2R, x8, 1866 MT/s 1R, x8, 2133 MT/s, A1, A2, A3, A4, A5, A6 1R, x8, 1866 MT/s...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 64
NOTE: Retain the removed memory-module blank(s) for future use. CAUTION: To prevent damage to the memory module or the memory-module socket during installation, do not bend or flex the memory module; insert both ends of the memory module simultaneously. Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the memory module in the socket.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Figure 25. Removing and installing a hard-drive adapter into a 3.5 inch hard-drive carrier 3.5 inch hard-drive carrier screw (5) hard-drive adapter 2.5 inch hard drive Removing a hard-drive adapter from a hard-drive carrier Prerequisites Ensure that you read the Safety instructions.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Figure 30. Replacing the internal USB key USB memory key USB memory key connector Next steps Follow the procedure listed in After working inside your system. While booting, press <F2> to enter the System Setup and verify that the USB key is detected by the system.
Page 83
Expansion- PCIe slot on the Processor Height Length Link Slot width card riser expansion-card connection width riser Processor 1 Half Height Half Height NOTE: The PCIE_G3_X8 and PCIE_G3_X16 are the two different types of risers supported on R430 systems. You can install an expansion card on the system board only using expansion-card riser. NOTE: The expansion cards are not hot-swappable.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 88
Figure 33. Removing and Installing the iDRAC port card iDRAC port card holder iDRAC port screw (2) SD vFlash media card iDRAC port card iDRAC port card connector Next steps Install the expansion card, if applicable. Install the expansion-card riser. Follow the procedure listed in After working inside your system.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 92
Figure 35. Removing and installing the Internal Dual SD Module (IDSDM) Internal Dual SD module LED status indicator (2) SD card (2) SD card slot 2 SD card slot 1 IDSDM connector The following table describes the IDSDM indicator codes: Table 20.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 94
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 97
Before upgrading your system, download the latest system BIOS version from dell.com/support and follow the instructions included in the compressed download file to install the update on your system. NOTE: You can update the system BIOS using the Lifecycle Controller. For more information about Dell Lifecycle controller, see dell.com/esmmanuals.
Page 98
processor open first socket release lever unlock icon Position your thumb firmly over the processor open first socket-release lever near the unlock icon and release the lever from the locked position by pushing down and out from under the tab. Similarly, position your thumb firmly over the processor close first socket-release lever near the lock icon and release the lever from the locked position by pushing down and out from under the tab.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 100
CAUTION: Positioning the processor incorrectly can permanently damage the system board or the processor. Be careful not to bend the pins in the socket. CAUTION: While removing or reinstalling the processor, wipe your hands of any contaminants. Contaminants on the processor pins such as thermal grease or oil can damage the processor.
Page 101
Figure 39. Applying thermal grease on the top of the processor 1. processor 2. thermal grease 3. thermal-grease syringe NOTE: The thermal-grease is intended for one-time use only. Dispose of the syringe after you use it. c. Place the heat sink onto the processor. d.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Figure 40. Applying thermal grease on the top of the processor processor thermal grease thermal grease syringe Place the heat sink onto the processor. Tighten one of the four screws to secure the heat sink to the system board. Tighten the screw diagonally opposite to the first screw you tightened. NOTE: Do not overtighten the heat sink retention screws when installing the heat sink.
NOTE: For AC power supplies, use only PSUs with the Extended Power Performance (EPP) label on the back. Mixing PSUs from previous generations of Dell PowerEdge servers can result in a PSU mismatch condition or failure to power on.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Next steps Follow the procedure listed in After working inside your system. Connect the power cable to the power supply and plug the cable into a power outlet. Removing the power supply unit blank If you are installing a second power supply unit, remove the power supply unit blank in the bay by pulling the blank outward.
Page 109
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 111
Figure 45. Removing and Installing the 3.5 inch or 2.5 inch (x4) SAS/SATA backplane guide (2) hard-drive/SSD backplane release tab (2) backplane power cable backplane signal cable SAS_A connector on the backplane hard-drive/SSD connector (4)
Page 112
Figure 46. Cabling diagram—3.5 inch or 2.5 inch (x4) SAS/SATA backplane SW_RAID_A connector on the system SATA_CDROM connector on the board system board cable routing latch SAS_A connector on the backplane Optical Disk Drive (ODD) hard-drive backplane system board...
Page 113
Figure 47. Removing and installing the 2.5 inch (x8) SAS/SATA backplane hard-drive/SSD backplane backplane power cable backplane signal cable SAS_A cable connector release tab (2) SAS_B cable connector hard-drive/SSD connector (8)
Page 114
Figure 48. Cabling diagram—2.5 inch (x8) SAS/SATA backplane integrated storage controller card SATA_CDROM connector on the system board cable routing latch Optical Disk Drive (ODD) SAS_A connector on the backplane SAS_ B connector on the backplane hard-drive/SSD backplane system board...
Page 115
Figure 49. Removing and installing the 2.5 inch (x10) SAS/SATA backplane hard drive/SSD backplane backplane power cable release tab (2) SAS_A connector on the backplane hard drive/SSD connector (10) SAS_B connector on the backplane SAS_C connector on the backplane...
Page 116
Figure 50. Cabling diagram—2.5 inch (x10) SAS/SATA backplane SW_RAID_A connector on the system SW_RAID_B connector on the system board board SATA_HDD8 connector on the system SATA_HDD9 connector on the system board board cable routing latch SAS_A connector on the backplane SAS_B connector on the backplane SAS_C connector on the backplane hard drive/SSD backplane...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 118
For an eight 2.5 inch hot-swappable hard-drive chassis, remove the screw (located at the bottom of the chassis) that secures the control panel to the chassis. For a ten 2.5 inch hot-swappable hard-drive chassis, Press the control panel latch and slide the control panel out of the chassis.
Page 119
Figure 52. Removing and installing the control panel—eight 2.5 inch hard-drives/SSDs chassis control panel notches (4) control panel module LCD connector cable...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 122
Figure 54. Removing and installing the control-panel module—four cabled hard-drive chassis screw (2) control-panel module connector cable control panel module USB connector cable control panel LED-panel screw (2) LED panel...
Page 123
Figure 55. Removing and installing the control panel module—four hard-drive chassis control-panel module control-panel module screws (2) control-panel module connector cable display module cable USB connector cable...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 128
Figure 58. Removing and installing the system board screw (9) system board system board t-handle Related Tasks Removing the cooling shroud Removing memory module Removing a cooling fan Removing an expansion card Removing the expansion-card riser Removing the integrated storage controller card Removing a processor Removing an internal SD card...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 130
If the Service Tag is not backed up in the backup flash device, enter the system service tag manually. See Entering the system Service Tag using System Setup. Update the BIOS and iDRAC versions. Re-enable the Trusted Platform Module (TPM). See Re-enabling the TPM for BitLocker users orRe-enabling the TPM for TXT users.
Import your new or existing iDRAC Enterprise license. For more information, see Integrated Dell Remote Access Controller User's Guide, at dell.com/ esmmanuals. Trusted Platform Module The Trusted Platform Module (TPM) is used to generate/store keys, protect/authenticate passwords, and create/store digital certificates. TPM can also be used to enable the BitLocker hard drive encryption feature in Windows Server.
Figure 59. Installing the TPM TPM connector slot on the TPM connector plastic bolt slot on the system board Next steps Follow the procedure listed in After working inside your system. Re-enabling the TPM for BitLocker users Initialize the TPM. For more information on initializing the TPM, see http://technet.microsoft.com/en-us/library/ cc753140.aspx.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
If the problem is resolved, restart the system, enter the System Setup, and check if the non- functioning USB ports are enabled. Check if USB 3.0 is enabled in System Setup. If enabled, disable it and see if the issue is resolved (older operating systems may not support USB 3.0).
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
System messages For a list of event and error messages generated by the system firmware and agents that monitor system components, see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals. Warning messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task.
Using system diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded. For information about embedded system diagnostics, see the ePSA Diagnostics Guide (Notebooks, Desktops and Servers) at dell.com/support/home.
Jumpers and connectors System board jumper settings For information about resetting the password jumper to disable a password, see Disabling a Forgotten Password. Table 21. System board jumper settings Jumper Setting Description PWRD_EN The password reset feature is enabled (pins 2–4). The password reset feature is disabled (pins 4–6).
System board connectors Figure 60. System board jumpers and connectors Table 22. System board jumpers and connectors Item Connector Description SYS_PWR_CONN (P1) 24-pin power connector FB_USB Front-panel USB connector PIB_CONN Power interposer board connector SATA_CDROM SATA connector CDROM MiniPERC PCIE_G3_X8 (CPU1) Mini PERC card connector SATA_TBU SATA connector tape backup unit...
Page 150
Item Connector Description BATTERY Battery connector TPM_MODULE Trusted platform module connector J_PSWD_NVRAM For more information, see System board jumper settings SLOT3 PCIE_G3_X16(CPU1) PCIe card connector 3 SLOT2 PCIE_G3_X16(CPU1) PCIe card connector 2 NOTE: The PCIE_G3_X8 and PCIE_G3_X16 are the two different types of risers supported on R430 systems.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Technical specifications Table 23. Physical specifications Physical Height 42.8 mm (1.68 inch) Width With rack latches 482.4 mm (18.99 inch) Without rack latches 434.0 mm (17.08 inch) Depth (excludes bezel) 607.0 mm (23.9 inch) Weight (maximum) 19.9 kg (43.87 lb) Weight (empty) 16.73 kg (36.88 lb) Table 24.
Page 153
Memory Support for advanced ECC or memory optimized operation Memory module sockets Twelve 288-pin Memory module capacities (RDIMMs) 4 GB (single-rank), 8 GB (single- and dual-rank), 16 GB (single- and dual-rank), and 32 GB (single- and dual-rank) Minimum RAM 4 GB with single processor 8 GB with dual processor Maximum RAM Up to 192 GB with single processor...
Page 154
Up to four 2.5-inch hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives. NOTE: Four hard-drive systems support software RAID. For more information on software RAID, see the Dell PowerEdge RAID Controller (PERC) documentation at dell.com/support/home. Eight hard-drive systems Up to eight 2.5-inch, hot-swappable SAS, SATA,...
Page 155
Video memory 16 MB shared Table 32. Environmental specifications Environmental specifications NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Storage –40°C to 65°C (–40°F to 149°F) Continuous operation (for altitude less than 950 10°C to 35°C (50°F to 95°F) with no direct m or 3117 ft) sunlight on the equipment.
Page 156
Environmental specifications Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 Maximum altitude 3048 m (10,000 ft).
Page 157
Do not perform a cold startup below 5 °C. • Allow processor performance degrade. • Non-redundant power supplies are not supported. • Non Dell qualified peripheral cards and/or peripheral cards are not supported. • Maximum altitude for the operating temperature must be 3050 m (10,000 ft).
Documentation feedback If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit to send your feedback. Quick Resource Locator (QRL) Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos.