  • Page 1 NEC plasma display External Control Manual (for PX-42VP5/42XM5/42XM3/50XM4/61XM3)
  • Page 2 Application These specifications applicable plasma monitors communications control from external equipment. "Please also support the command of VP series and refer to the manual of the conventional model about specification." Connections Connections should be made as described below. External equipment plasma monitor e.g., Personal computer 1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.
  • Page 3 2) Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is to be connected for the type of connector and the pin assignment. 3) Wiring Use a crossed (reverse) cable. Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive data) and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS (Clear to send).
  • Page 4 Communication Format 8bit 8bit 8bit 8bit 8bit 8bit 8bit 8bit Command 1 Unit ID 1 Unit ID 2 Command 2 Data length Data Check sum Command1 Command 1, along with command 2, is a number used to distinguish each command. When making it operate using ID, bit1 and bit0 are set up as follows.
  • Page 5 1) Unit ID 1: Indicates the equipment sending the signal. When supporting Set ID by the command 1, 4 bits of low ranks of Set ID are set up. 2) Unit ID 2: Indicates the equipment receiving the signal. When supporting Set ID by the command 1, 4 bits of higher ranks of Set ID are set up.
  • Page 6 Command 2 Command 2, along with command 1, is a number used to distinguish each command. Check Sum (CKS), Error Processing, and ACK 1) The check sum described below and RS-232C odd parity are used together for a check of the received data. The check sum is the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2, Command 2, Data Length, and Data.
  • Page 7 The control method of the set by Set ID When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable individually. The example of the POWER ON command to the plasma monitor which set ID as "5"...
  • Page 8 Command Reference List CMD1 CMD2 Power ON Power OFF Input Switch Change VOLUME Gain Data AUDIO Mute ON AUDIO Mute OFF CONTRAST Gain Data BRIGHT Gain Data SHARPNESS Gain Data Color Gain Data TINT Gain Data PICTURE MODE Select COLOR TEMP SELECT RED Gain Data GREEN Gain Data BLUE Gain Data...
  • Page 9: Present Time Setting

    COLOR SYSTEM Select FREQUENCY Request Input MODE Request VIDEO ADJ Request Audio Select Request Failure Mode Request MODEL NAME Request D-SUB INPUT TIMER SWITCH LOW TONE COLOR TUNE TIMER PROGRAM SETTING PRESENT TIME SETTING MULTI MODE Select MULTI MODE Request AUTO ID SET START PLE LINK VIDEO WALL SETTING...
  • Page 10 MULTI(SPRIT) SCREEN POWER ON MODE MULTI(SPRIT) SCREEN REPEAT TIMER OSM CONTRAST CLOSECAPTION (Closed Caption) CAPTION CONT *1:This function is only 50 or 61 inch model *2:This function is only A version...
  • Page 11 01. Power ON Function The external control equipment switches on the power of the plasma monitor. Transmission Data 9FH 80H 60H 4EH 00H CKS The plasma monitor returns the following ACK when the power is switched 3FH 60H 80H 4EH 00H CKS NOTE: Do not set the Power ON or Power OFF command continuously.
  • Page 12 03. Input Switch Change Function The external control equipment switches the input of the plasma monitor. Transmission Data DFH 80H 60H 47H 01H DATA00 DATA00 : Input Select 01H : Video1 02H : Video2 03H : Video3 05H : HD (HD1 or DTV or DTV1) 06H : HD2(DTV2 or SCART1/SCART2) 07H : RGB1 / PC1 08H : RGB2 / PC2...
  • Page 13 04. VOLUME Gain Data Function The external control equipment changes the VOLUME gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER SOUND Gain Flag 05H DATA01: VOLUME Gain Flag DATA02: VOLUME Gain 00H: Step0 0AH: Step10 (Default) 2AH: Step42...
  • Page 14 07. CONTRAST Gain Data Function The external control equipment changes the CONTRAST gain data of the plasma c Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag DATA01 : CONTRAST Gain Flag DATA02 : CONTRAST Gain CCH : -52 FFH : -01...
  • Page 15 DATA00 : USER PICTURE Gain Flag DATA01 : BRIGHT Gain Flag 09. SHARPNESS Gain Data Function The external control equipment changes the SHARPNESS gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag DATA01 : SHARPNESS Gain Flag DATA02 : SHARPNESS Gain...
  • Page 16 10. COLOR Gain Data Function The external control equipment changes the COLOR gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : COLOR Gain Flag DATA02 : COLOR Gain E0H : -32 FFH : -01 00H : 0...
  • Page 17 7FH 60H 80H 7FH 02H DATA00 DATA01 DATA00 : USER PICTURE Gain Flag DATA01 : TINT Gain Flag 12. PICTURE MODE Select Function The external control equipment sets the picture mode of the plasma monitor. Transmission Data DFH 80H 60H 0AH 01H DATA00 DATA00: 01H : NORMAL 02H : THEATER1(It cannot choose in the still picture input of a personal computer.)
  • Page 18 7FH 60H 80H 00H 01H DATA00 DATA00 : 00H: low 01H: middle 02H: high 03H: middle low 14. RED Gain Data Function The external control equipment changes the RED Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : RED Gain Flag DATA02 : RED Gain1(Bias)
  • Page 19 15. GREEN Gain Data Function The external control equipment changes the GREEN Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : GREEN Gain Flag DATA02 : GREEN Gain1(Bias) D8H : -40 FFH : -01...
  • Page 20 16. BLUE Gain Data Function The external control equipment changes the BLUE Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : BLUE Gain Flag DATA02 : BLUE Gain1(Bias) D8H :-40 FFH : -01...
  • Page 21: Nr Mode Set

    17. NR MODE Set Function The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor. Transmission Data DFH 80H 60H C0H 01H DATA00 DATA00: 01H : NR OFF 02H : NR-1 03H : NR-2 04H : NR-3 7FH 60H 80H C0H 01H DATA00 DATA00: 01H : NR OFF 02H : NR-1...
  • Page 22 19. TREBLE Gain Data Function The external control equipment changes the TREBLE gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : TREBLE Gain Flag DATA02 : TREBLE Gain F3H : -13 FFH : -01 00H : 0...
  • Page 23 DATA01: BALANCE Gain Flag 21.SCREEN MODE Select Function The external control equipment switches the screen mode of the plasma monitor. Transmission Data DFH 80H 60H 51H 01H DATA00 DATA00 02H : STADIUM 03H : ZOOM 04H : NORMAL 05H : FULL 06H : REAL 08H : UNDERSCAN 09H : 14:9...
  • Page 24 22. V.POSITION Gain Data Function The external control equipment changes the V. POSITION gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : V.POSITION Gain Flag DATA02 : V.POSITION Gain C0H : -64 FFH : -01...
  • Page 25 23. H.POSITION Gain Data Function The external control equipment changes the H. POSITION gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag DATA01 : H.POSITION Gain Flag DATA02 : H.POSITION Gain 80H : -128 FFH : -01...
  • Page 26 25. H-WIDTH Gain Data Function The external control equipment changes the H-WIDTH gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : H-WIDTH Gain Flag DATA02 : H-WIDTH Gain 00H : 0 40H : +64 7FH 60H 80H 7FH 02H DATA00...
  • Page 27 27. PHASE Gain Data Function The external control equipment changes the PHASE gain data (Phase) of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : PHASE Gain Flag DATA02 : PHASE Gain 00H : 0 40H : +64...
  • Page 28 29. OSM Select Function The external control equipment switches on or off the on-screen menu (OSM) of the plasma monitor. Transmission Data DFH 80H 60H 58H 01H DATA00 DATA00: 01H: On-Screen menu On 02H: On-Screen menu Off 7FH 60H 80H 58H 01H DATA00 DATA00: 01H: On-Screen menu On 02H: On-Screen menu Off...
  • Page 29 31. POWER MGT Select Function The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor. Transmission Data DFH 80H 60H 1AH 02H DATA00 DATA01 CKS DATA00 : POWER MGT Select DATA01 01H : ON 02H : OFF 7FH 60H 80H 1AH 02H DATA00 DATA01 CKS DATA00 : POWER MGT Select...
  • Page 30 33. CINEMA MODE Set Function The external control equipment switches on or off the CINEMA MODE of the plasma monitor. Transmission Data DFH 80H 60H C1H 01H DATA00 DATA00 : CINEMA MODE Set 01H : ON 02H : OFF 7FH 60H 80H C1H 01H DATA00 DATA00 : CINEMA MODE Set 01H : ON 02H : OFF...
  • Page 31: Inverse Set

    35. INVERSE Set Function The external control equipment sets the INVERSE (inverse of image brightness) and the WHITE of the plasma monitor. Transmission Data DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS DATA00: INVERSE/WHITE 00H : No operation 01H : ON (INVERSE) 02H : OFF 03H : WHITE DATA01 : WORKING TIME...
  • Page 32: Screen Wiper Set

    36. SCREEN WIPER Set Function The external control equipment sets the SCREEN WIPER of the plasma monitor. Transmission Data DFH 80H 60H C8H 04H DATA00 to DATA03 CKS DATA00 : SCREEN WIPER 00H : No operation 01H : ON 02H : OFF DATA01 : WORKING TIME 00H : ON 01H: 03M (minutes)
  • Page 33: All Reset

    37. ALL RESET Function The external control equipment resets the user adjustment of the plasma monitor. Transmission Data 1FH 80H 60H 54H 00H CKS 3FH 60H 80H 54H 00H 38. Audio Select Set Function The external control equipment sets combinations of audio and video inputs for the plasma monitor.
  • Page 34: Bnc Input

    39. BNC INPUT Function The external control equipment sets the BNC SELECT of the plasma monitor. Transmission Data DFH 80H 60H 8CH 01H DATA00 CKS DATA00 : BNC SELECT 01H : RGB 02H : Component 04H : SCART1(*:Only Europe can be chosen.) 05H : SCART2(*:Only Europe can be chosen.) The plasma monitor returns the following ACK when setting the BNC SELECT: 7FH 60H 80H 8CH 01H DATA00 CKS...
  • Page 35 05H : WIDE2 06H : DTV 07H : WIDE3 08H : WIDE4 41. HD Select Function The external control equipment sets the HD SELECT of the plasma monitor. Transmission Data DFH 80H 60H 8AH 01H DATA00 DATA00 01H : 1035I 02H : 1080A 03H : 1080B 7FH 60H 80H 8AH 01H...
  • Page 36 7FH 60H 80H 5BH 01H DATA00 DATA00: 01H : ENGLISH 02H : GERMAN 03H : FRENCH 04H : SPANISH 05H : ITALIAN 06H : SWEDISH 07H : JAPANESE 0AH : CHINESE 0BH•F RUSSIAN NOTE: As for the change to JAPANESE (07H), SHIP needs to be set as "J."...
  • Page 37 0BH : PAL60 0DH : PAL-M 0EH : PAL-N 44. FREQUENCY Request Function The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma monitor. Transmission Data 1FH 80H 60H 26H 00H CKS 7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS Horizontal frequency DATA00: Integer part...
  • Page 38 MODE DATA06 •| No signal 01H to 80H RGB signal Identification number of PC mode 3.58NTSC Video signal 4.43NTSC PAL-M PAL-N PAL60 SECAM B/W60 B/W50 480I HD/DVD/DTV signal 480P 576I 576P 720P 1035I 1080I RESOLUTION DATA07: Dots (Low-order byte) 00H: 0 (No signal: 00H) DATA08: Dots (High-order byte) 00H: 257 (No signal: 00H) DATA09: Lines (Low-order byte) 00H: 0 (No signal: 00H) DATA10: Lines (High-order byte) 00H: 257 (No signal: 00H)
  • Page 39 45. Input MODE Request Function The display returns the current input information by the external control equipment’ s request. Transmission Data 1FH 80H 60H 41H 00H CKS 7FH 60H 80H 41H 01H DATA00 DATA00 : Input Select 01H : Video 02H : Video2 03H : Video3 04H : HD (HD1 or DTV or DTV1)
  • Page 40 FFH : -01 00H : 0 01H : +01 1EH : +30 DATA02: BLUE Gain (Bias) D8H : -40 FFH : -01 00H : 0 01H : +01 1EH : +30 DATA03: COLOR Gain E0H : -32 * COLOR Gain is from -22 (EAH) to FFH : -01 +22 (16H) only during video.
  • Page 41 FFH : -01 00H : 0 01H : +01 14H : +20 DATA07: BRIGHT Gain E0H : -32 FFH : -01 00H : 0 01H : +01 20H : +32 DATA08: RED Gain (Drive) D8H : -40 FFH : -01 00H : 0 01H : +01 1EH : +30...
  • Page 42 1EH : +30 DATA0B: COLOR TEMP SELECT 00H: low 01H: middle 02H: high 03H: middle low 47. Audio Select Request Function The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor. Transmission Data 1FH 80H 60H 6FH 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 6FH 03H DATA00 DATA01...
  • Page 43 48. Failure Mode Request Function The external control equipment inquires the detection of failures of the plasma monitor. Transmission Data 1FH 80H 60H 3FH 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 3FH 02H DATA00 DATA01 DATA00: FAILURE MODE 1 Bit 0 : PDP MODULE 0: Abnormal...
  • Page 44 49. MODEL NAME Request Function The external control equipment inquires the product code of the plasma monitor. Transmission Data 1FH 80H 60H 17H 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS DATA00 : 1st character of the product code DATA01 : 2nd character of the product code DATA11 : 12th character of the product code...
  • Page 45 would be padded right with blanks. Example: If the product code of your plasma monitor is “PX-42VP4G”, the returned codes would be as follows. DATA00:1FH, DATA01:27H, DATA02:80H, DATA03:04H, DATA04:02H, DATA05:25H, DATA06:1FH, DATA07:04H, DATA08:16H, DATA09:96H, DATA10:96H, DATA11:96H...
  • Page 46: Timer Switch

    50. D-SUB INPUT Function The external control equipment sets the D-SUB SELECT of the plasma monitor. Transmission Data DFH 80H 60H 8DH 01H DATA00 CKS DATA00 : D-SUB INPUT 01H : RGB 02H : SCART3(*:Only Europe can be chosen.) The plasma monitor returns the following ACK when setting the D-SUB SELECT: 7FH 60H 80H 8DH 01H DATA00 CKS DATA00 : D-SUB INPUT...
  • Page 47 52.LOW TONE Function The external control equipment sets the dithering processing or error diffusion processing of the plasma monitor. Transmission Data DFH 80H 60H 0CH 01H DATA00 CKS DATA00: 00H:AUTO 01H: dithering processing(MOTION) 02H: dithering processing (STILL) 03H: error diffusion processing 7FH 60H 80H 0CH 01H DATA00 CKS DATA00: 00H:AUTO...
  • Page 48: Color Tune

    53.COLOR TUNE Function External control equipment can adjust RGB each color which a plasma monitor wants to emphasize. Transmission Data DFH 80H 60H 0DH 07H DATA00 to DATA06 CKS DATA00:RED 00H : -32 20H : 0 40H : +32 DATA01:GREEN 00H : -32 20H : 0 40H : +32...
  • Page 49 01H : ON 7FH 60H 80H 0DH 00H CKS 54.TIMER PROGRAM SETTING Function External control apparatus sets up the timer program of a plasma monitor. Transmission Data DFH 80H 60H 30H 08H DATA00 to DATA07 CKS DATA00 PROGRAM No 01H~07H :No1~No7 DATA01 DATE 01H~07H...
  • Page 50 10H~19H :10~19 20H~29H :20~29 30H~39H :30~39 40H~49H :40~49 50H~59H :50~59 FFH : - (with No Setup) DATA06 INPUT : Video1 : Video2 : Video3 : HD1(HD1 or DTV or DTV1) : HD2(DTV2 or SCART1/SCART2) : RGB1 : RGB2 : RGB3 : HD3(SCART3) : - (with No Setup) DATA07 MODE...
  • Page 51 55.PRESENT TIME SETTING Function External control apparatus sets up the present time of a plasma monitor. Transmission Data DFH 80H 60H 31H 03H DATA00 to DATA02 CKS DATA00 Day of the week 01H-07H : 1-7 (Sunday - Saturday) DATA01 HOUR 00H-09H:00-09 10H~19H:10~19 20H~23H:20~23...
  • Page 52 08H : Top middle selected (9 screens) 09H : Top right selected (9 screens) 0AH : Middle left selected (9 screens) 0BH : Middle centerselected (9 screens) 0CH : Middle rightselected (9 screens) 0DH : Bottom leftselected (9 screens) 0EH : Bottom middle selected (9 screens) 0FH : Bottom right selected (9 screens) 10H : position1(16 screens,refer to figure1) 11H : position2(16 screens,refer to figure1)
  • Page 53 01H : BRANKING 7FH 60H 80H 03H 03H DATA00 DATA01 DATA02 CKS DATA00 (SCREEN DIVIDER SETTING) 01H : Single mode 02H : Multi mode 1 screens 03H : Multi mode 4 screens 04H : Multi mode 9 screens 05H : Multi mode 16 screens 06H : Multi mode 25 screens DATA01 (POSITION OF DIVIDE) 01H : Upper left selected (4 screens)
  • Page 54 2AH : position11(25 screens,refer to figure2) 32H : position19(25 screens,refer to figure2) 33H : position20(25 screens,refer to figure2) 38H : position25(25 screens,refer to figure2) Figure1 Figure2 DATA02 (DISP MODE) 00H : SPLIT 01H : BRANKING Note) In the case of 4 screens or 9 screens video wall system and connecting each PDP by wired cable, please refer to No.60.”VIDEO WALL SETTING”.
  • Page 55: Multi Mode Request

    57.MULTI MODE Request Function External control apparatus can know the MULTI MODE information on a plasma monitor. Transmission Data 1FH 80H 60H 3BH 00H CKS 7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS DATA00 (SCREEN DIVIDER SETTING) 01H : Single mode 02H : Multi mode 1 screens 03H : Multi mode 4 screens 04H : Multi mode 9 screens...
  • Page 56 20H : position1(25 screens,refer to figure2) 21H : position2(25 screens,refer to figure2) 29H : position10(25 screens,refer to figure2) 2AH : position11(25 screens,refer to figure2) 32H : position19(25 screens,refer to figure2) 33H : position20(25 screens,refer to figure2) 38H : position25(25 screens,refer to figure2) Figure1 Figure2 DATA02 (DISP MODE)
  • Page 57 58.AUTO ID SET START Function External control apparatus sets up ID automatically to two or more plasma monitors. Transmission Data 5FH 80H 60H F0H 01H DATA00 CKS DATA00 00H~FFH: ID of a master is set up. *: When you use it by the multi-system, please remove the link input of a master *1: “Master”...
  • Page 58 *1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution. 60.VIDEO WALL SETTING Function External control apparatus sets 4screens or 9screens as a video wall. Transmission Data DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS DATA00: 01H:1 screen (Matrix diplay function does not work.)
  • Page 59 61.POWER DELAY ON(at 4 or 9 multiscreen) Function External control apparatus attaches a time lag to two or more plasma monitors, and turns on a power supply. Transmission Data DFH 80H 60H F2H 01H DATA00 CKS DATA00: 00H-FFH: Delay time (second) *: This command is premised on two or more plasma monitor system composition being multi-systems.
  • Page 60: Gamma Gain Data

    63.GAMMA GAIN Data Function External control apparatus changes Gamma of a plasma monitor. Transmission Data DFH 80H 60H 13H 02H DATA00 DATA01 CKS DATA00: GAMMA FLAG 01H : Gamma change DATA01: GAMMA 00H :1 01H :2 02H :3 03H :4 7FH 60H 80H 13H 01H DATA00 CKS DATA00: GAMMA FLAG 01H : Gamma change...
  • Page 61 65.ORBITER SET Function A picture shift function is set up. (*1) Transmission Data DFH 80H 60H 1EH 04H DATA00 to DATA03 CKS DATA00: Mode 00H : OFF 01H : Auto 1 (*2) 02H : Auto 2 (*3) 03H : Manual (*4) DATA01: The horizontal amount of movements 1 dot : 01H 20 dot : 14H...
  • Page 62 66. OSM OBITER Function In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out. Transmission Data DFH 80H 60H 5FH 01H DATA00 DATA00 01H : OBITER ON 02H : OBITER OFF 7FH 60H 80H 5FH 01H DATA00 DATA00 01H : OBITER ON...
  • Page 63 69. PICTURE Size Function Screen mode selection. Transmission Data DFH 80H 60H 2AH 01H DATA00 DATA00 01H : ON 02H : OFF 7FH 60H 80H 2AH 01H DATA00 DATA00 01H : ON 02H : OFF *This function is only 50 or 61 inch model. 70.
  • Page 64 71.REPEAT Timer Function External control apparatus sets up the repeat timer of a plasma monitor. Transmission Data DFH 80H 60H 64H 07H DATA00 to DATA06 CKS DATA00 00H :REPEAT Timer OFF 01H :REPEAT Timer ON DATA01 PROGRAM 1 01H :DIVIDER 1 02H :DIVIDER 4 03H :DIVIDER 9 DATA02 SOURCE 01H :Video1...
  • Page 65 7FH 60H 80H 64H 00H CKS 72. SERIAL No. Request Function the serial number of the set recorded by External control apparatus read EEPROM of a plasma display. Transmission Data 1FH 80H 60H 15H 00H CKS 7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS Even DATA00-DATA11 is set up as follows.
  • Page 66 74.SOFT FOCUS Function External control apparatus sets up the Soft Focus of a plasma monitor. Transmission Data DFH 80H 60H 65H 01H DATA00 CKS DATA00 01H : OFF 02H : 1 03H : 2 04H : 3 05H : 4 7FH 60H 80H 65H 01H DATA00 CKS DATA00 01H : OFF...
  • Page 67 76.DEGITAL SIGNAL LEVEL SELECT (only HDCP model) Function External control apparatus sets up the digital signal level of a plasma monitor. Transmission Data DFH 80H 60H 8FH 01H DATA00 CKS DATA00 01H : LOW 02H : HIGH 7FH 60H 80H 8FH 01H DATA00 CKS DATA00 01H : LOW 02H : HIGH...
  • Page 68 44H: Picturein Picture 3(sub screen Top Right) with size4 45H: Picturein Picture 4(sub screen Top Left) with size1 46H: Picturein Picture 4(sub screen Top Left) with size2 47H: Picturein Picture 4(sub screen Top Left) with size3 48H: Picturein Picture 4(sub screen Top Left) with size4 49H: Side by Side 3 (Same Size Screen vertical expand) 4AH: Side by Side 4 R(Left Screen smaller vertical expand) 4BH: Side by Side 4 L(Left Screen Bigger vertical expand)
  • Page 69: Zoom Navigation Select

    4AH: Side by Side 4R (Left Screen smaller vertical expand) 4BH: Side by Side 4L (Left Screen Bigger vertical expand) In case of Side by Side mode; 20H: Active Left 21H: Active Right In case of Picture in picture mode; 30H: Active Main 31H: Active Sub 78.
  • Page 70: Picture Freeze Select

    02H : Side By Side 03H : Picture in Picture1(Sub Screen Bottom Left) 04H : Picture in Picture2(Sub Screen Bottom Right) 05H : Picture in Picture3(Sub Screen Top Right) 06H : Picture in Picture4(Sub Screen Top Left) 80.PICTURE FREEZE SELECT Function External control apparatus selects the picture freeze function of a plasma monitor.
  • Page 71 7FH 60H 80H 7DH 01H DATA00 CKS DATA00 01H : FREEZE 02H : FREEZE OFF 82.SEAMLESS SWITCH SELECT Function External control apparatus selects the seamless switch function of a plasma monitor. Transmission Data DFH 80H 60H 7EH 01H DATA00 DATA01 DATA02 CKS DATA00: SEAMLESS SWITCH :OFF DATA01 : SELECT1...
  • Page 72 83.MULTI •i SPRIT•j SCREEN PROGRAM TIMER SET Function External control apparatus sets multi (sprit) screen program timer of a plasma monitor. Transmission Data DFH 80H 60H 32H 0AH DATA00•`DATA09 CKS DATA00 PROGRAM No 01H•`07H :No1•`No7 DATA01 DATE 01H•`07H : Sunday~Saturday 08H : Everyday 09H•`0FH:Every Sunday~Every Saturday FFH : - (no setteing)
  • Page 73 04H : Picture in Picture1(Sub Screen Bottom Left) 05H : Picture in Picture2(Sub Screen Bottom Right) 06H : Picture in Picture3(Sub Screen Top Right) 07H : Picture in Picture4(Sub Screen Top Left) DATA07 INPUT1•iLeft or main•j 01H : Video1 02H : Video2 03H : Video3 05H : HD (HD1 or DTV or DTV1) 06H : HD2 (DTV2 or SCART1/SCART2)
  • Page 74 84.MULTI •i SPRIT•j SCREEN POWER ON MODE SET Function External control apparatus sets “multi (sprit) screen power on mode” of a plasma monitor. Transmission Data DFH 80H 60H 33H 04H DATA00•`DATA03 CKS DATA00 POWER ON MODE 01H:LAST 02H:MULTI DATA01 MULTI MODE 01H : Side By Side1(Same Size Screen) 02H : Side By Side2(Left Screen Smaller) 03H : Side By Side2(Left ScreenBigger)
  • Page 75 0DH : HD3(SCART3) 7FH 60H 85.MULTI •i SPRIT•j REPEAT TIMER SET Function External control apparatus sets “multi (sprit) screen repeat timer” of a plasma monitor. Transmission Data DFH 80H 60H 34H 09H DATA00•`DATA03 CKS DATA00 REPEAT TIMER 00H:OFF 01H:ON REPEAT1 DATA01 MULTI MODE 00H : SINGLE 01H : Side By Side1(Same Size Screen)
  • Page 76 06H : HD2 (DTV2 or SCART1/SCART2) 07H : RGB1 / PC1 08H : RGB2 / PC2 0CH : RGB3 / PC3 0DH : HD3(SCART3) DATA04 WORK TIME 01H•`FFH : 1•`255 minutes •i1 minutes•`4 hour 15 minutes•j REPEAT2 DATA05 MULTI MODE 00H : SINGLE 01H : Side By Side1(Same Size Screen) 02H : Side By Side2(Left Screen Smaller)
  • Page 77: Osm Contrast Select

    0DH : HD3(SCART3) DATA08 WORK TIME 01H•`FFH : 1•`255 minutes minutes•`4 •i1 hour 15 minutes•j NOTE: When “SINGLE” is selected at DATA01 or DATA04, ”INPUT MODE 1” will be repeated. 7FH 60H 86.OSM CONTRAST SELECT Function External control apparatus selects the OSM contrast function of a plasma monitor.
  • Page 78 87.CC (Closed caption) SELECT Function External control apparatus selects the Closed Caption function of a plasma monitor. Transmission Data DFH 80H 60H 3CH 01H DATA00 CKS DATA00 00H : OFF 01H : CC1(closed caption1) 02H : CC2(closed caption2) 03H : CC3(closed caption3) 04H : CC4(closed caption4) 05H : TEXT1 06H : TEXT2...
  • Page 79 88.CC (Closed caption) CONTRAST SELECT Function External control apparatus selects the Closed Caption Contrast function of a plasma monitor. Transmission Data DFH 80H 60H 3DH 01H DATA00 CKS DATA00 01H : NORMAL 02H : LOW 7FH 60H 80H 3DH 01H DATA00 CKS DATA00 01H : NORMAL...