Music Center: SA-HT1000EBS System : SC-HT1000EBS Front speakers: SB-PF1000P-S (x 2) Center speaker: SB-PC1000P-S (x 1) Surround speakers: SB-PS1000P-S (x 2) Active Subwoofer: SB-WA340EBS1 Music Center: SA-HT1000EGS System : SC-HT1000EGS Front speakers: SB-PF1000P-S (x 2) Center speaker: SB-PC1000P-S (x 1)
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
each point. 5. Reverse the AC plug in the AC outlet and repeat each of the above measurements. 6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed 1/2 milliamp.
the amplifier are used. If this occurs, follow the procedure outlines below: 1. Turn off the power. 2. Determine the cause of the problem and correct it. 3. Turn on the power once again after one minute. Note : When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
Page 6
Some chassis components may have sharp edges. Be careful when disassembling and servicing. 1. This section describes procedures for checking the operation of the major printed circuit boards and replacing the main components. 2. For reassembly after operation checks or replacement, reverse the respective procedures.
Page 7
Step 2: Remove all screws. Step 3: Remove the Stand Base. Step 4: Remove all screws from the speaker bottom. Step 5: Pull the Power/Amp Unit as shown.
Page 8
Step 6: Release the connector CN506 and pull out the Power/Amp Unit. Step 7: Push the Net Frame from two holes inside the unit. Step 8: Remove the Net Frame. Step 9: Remove all the screws.
Page 9
Step 10: Remove the Speaker. Step 11 & 12: Remove all the screws. Step 13: Release the connector CN507. Step 14: Remove the 2 screws.
Page 10
Step 15 & 16: Remove all the screws. Step 17: Place the Power PCB as shown for checking. Checking for AC Inlet PCB. 6.2. Main Component Replacement Procedures...
6.2.1. Replacement of the Power IC Step 1 & 2: Remove all the screws. Step 3: Desolder the Power IC terminal and replace the component. 7. Connection of the Speaker Wiring 8. Block Diagram...
9. Schematic Diagram (All schematic diagrams may be modified at any time with the development of the new technology) Note: - The voltage value and waveforms are the reference voltage of this unit measured by DC electronic voltmeter (high impedance) and oscilloscope on the basis of chassis.
Page 13
When replacing any of these components, be sure to use only manufacturer’s specified parts shown in the parts list. - The parenthesized indications in the Remarks columns specify the areas or colour. (Refer to the cover page for area or colour) Parts without these indications can be used for all areas.
Page 25
CN501 7..1 CP502 JK502 LED P.C.B. CN507 SPEAKER JK501 WOOFER H505A/W505 SOLDER SIDE SOLDER SIDE POWER P.C.B. SOLDER SIDE T501(POWER TRANSFORMER) TRANSFORMER P.C.B. T502(POWER TRANSFORMER) AC INLET AC IN JK500 P.C.B. 230~240V 50HZ CN502 SOLDER SIDE 7.
Page 26
IC501 RSN311W64B-P POWER HIC POWER CONTROL CIRCUIT POWER CONTROL/PROTECTION CIRCUIT 12(11) (25) (19) D501 D502 Q506 INTERFACE SWITCH TO MAIN BLOCK Q505 (JK700) OF SA-HT1000EB/EG-S SWITCHING SL(R)/SURRL(R) FILTER FILTER JK501(JK502) SURROUND SPEAKER CCH/CENTRE FILTER FILTER JK502 CENTRE SPEAKER FILTER SUBWOOFER FL(R)/FRONTL(R) FILTER FILTER...
Page 30
AC INLET P.C.B. (REPX0375C) CAUTION RISK OF ELECTRIC SHOCK AC VOLTAGE LINE. PLEASE DO NOT TOUCH THIS P.C.B FC502 FC501 F1 250V T2AL T502 (POWER TRANSFORMER) L500 JK500 Q516 AC IN J500 RLY501 C555 J501 230V-240V R589 50HZ C557 R578 C558 J502 J503...
Page 31
SCHEMATIC DIAGRAM-1 : MAIN SIGNAL LINE : -B SIGNAL LINE POWER CIRCUIT : +B SIGNAL LINE IC501 C551 IC501 0.01 RSN311W64B-P POWER HIC E501 K4CZ01000027 R501 R513 4.7K R502 C507 18P 4.7K R514 C508 18P R524 120K R506 D501-D502 B0JAPG000019 R516 R526 R505...
Page 32
SCHEMATIC DIAGRAM-2 : MAIN SIGNAL LINE : -B SIGNAL LINE POWER CIRCUIT : +B SIGNAL LINE R597 R594 C564 1200P Q514 R592 R403 R599 Q513 100K C565 R593 R571 C568 R591 R572 3.3K 0.01 6.8K 470K C562 IC502 5600P C0AABB000055 C524 C525 DUAL LOW-NOISE OP AMP...
Registration Number : 197701580H All rights reserved. Unauthorized copying and distribution is a violation of law. 1. Parts Location & Replacement Parts List With reference to Original Service Manual on page 21 for Model No. SB-WA340EBS1. 1.1. Cabinet 1.1.1. Cabinet Parts Location (Changes)
Page 35
1.2. Cabinet Parts List (Changes) With reference to Original Service Manual on page 22 for Model No. SB-WA340EBS1. BEFORE AMENDMENTS...
Page 36
Ref. No. Part No. Part Name & Description Remarks CABINET AND CHASSIS RFKHBWA302-S SPK CABINET ASS’Y RYB0298A NET FRAME ASS’Y AFTER AMENDMENTS Ref. No. Part No. Part Name & Description Remarks CABINET AND CHASSIS RFKHBWA302-S SPK CABINET ASS’Y CATCHER PIN RKQP0252-1 [M] ADDED RYB0298G...