KX-TG1061M/KX-TG1062M/KX-TGA106M TABLE OF CONTENTS PAGE PAGE 1 Safety Precautions----------------------------------------------- 4 12.4. How to Replace the LLP (Leadless Leadframe 1.1. For Service Technicians --------------------------------- 4 Package) IC ----------------------------------------------- 82 2 Warning -------------------------------------------------------------- 4 12.5. How to Replace the LLP (Leadless Leadframe 2.1.
KX-TG1061M/KX-TG1062M/KX-TGA106M 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work.
KX-TG1061M/KX-TG1062M/KX-TGA106M 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu), or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufac- turer’s specific instructions for the melting points of their products and any precautions for using their product with other materi-...
KX-TG1061M/KX-TG1062M/KX-TGA106M 3 Specifications Note: • Design and specifications are subject to change without notice. Note for service: • Operation range: Up to 300 m outdoors, Up to 50 m indoors, depending on the condition. • Optional headset: KX-TCA60, KX-TCA86, KX-TCA92, KX-TCA93, KX-TCA94...
KX-TG1061M/KX-TG1062M/KX-TGA106M 4 Technical Descriptions 4.1. US-DECT Description The frequency range of 1.92 GHz-1.93 GHz is used. Transmitting and receiving carrier between base unit and handset is same fre- quency. Refer to Frequency Table (MHz) (P.75). 4.1.1. TDD Frame Format 4.1.2.
KX-TG1061M/KX-TG1062M/KX-TGA106M 4.3. Circuit Operation (Base Unit) 4.3.1. Outline Base unit consists of the following ICs as shown in Block Diagram (Base Unit) (P.8). • DECT BBIC (Base Band IC): IC501 - Handling all the audio, signal and data processing needed in a US DECT base unit...
Page 10
KX-TG1061M/KX-TG1062M/KX-TGA106M 4.3.2. Power Supply Circuit The power is supplied to the BBIC,TAM Companion,Power AMP,LCD module,EEPROM,Flash Memory,LED,LCD backlight from AC Adaptor(+6.5V) as shown in Fig 1. When power line failure, the power is supplied to BBIC,TAM companion,EEPROM from telephone line instead of AC Adaptor through D138 and Q341.
Page 11
KX-TG1061M/KX-TG1062M/KX-TGA106M 4.3.3. Telephone Line Interface Function • Bell signal detection • CLIP signal detection • ON/OFF hook and pulse dial circuit Bell & CLIP (Calling Line Identification Presentation: Caller ID) signal detection: In standby mode,Q111/Q115 is open to cut the DC Loop current and decrease the ring load.
Page 12
KX-TG1061M/KX-TG1062M/KX-TGA106M 4.3.5. RF cuircuit BBIC(IC501) inclueds the RF transceiver circuit. (LNA,Mixer, IF filter, modulator/Demodulator,PLL, VCO etc). This RF transceiver is interfaced with Power-AMP(IC801) and Antenna circuit.
KX-TG1061M/KX-TG1062M/KX-TGA106M 4.5. Circuit Operation (Cordless Handset) 4.5.1. Outline Cordless Handset consists of the following ICs as shown in Block Diagram (Cordless Handset) (P.13). • DECT BBIC (Base Band IC): IC1 - All data signals (forming/analyzing ACK or CMD signal) - All interfaces (ex: Key, Detector Circuit, Charge, DC/DC Converter, EEPROM, LCD, RF Power Amp.)
KX-TG1061M/KX-TG1062M/KX-TGA106M 6 Installation Instructions 6.2. Battery 6.2.1. Battery Installation 6.1. Setting up 6.1.1. Connections Note: • The AC adaptor must remain connected at all times. (It is normal for the adaptor to feel warm during use.) • The AC adaptor should be connected to a vertically oriented or floor-mounted AC outlet.
Page 21
• The batteries need to be charged if the cordless handset beeps while you are engaged in a call or operating the answering system remotely. 6.2.4. Panasonic Ni-MH Battery Perfor- mance (supplied batteries) Note: • Actual battery performance depends on a combination of how often the handset is in use and how often it is not in use (standby).
KX-TG1061M/KX-TG1062M/KX-TGA106M 7 Operating Instructions 7.1. Programmable settings You can customize the unit by programming the following features. To access the features, there are 2 methods: - scrolling through the display menus. - using the direct commands. • Direct command is the main method used in this service manual.
KX-TG1061M/KX-TG1062M/KX-TGA106M 7.2. Registering a Cordless Handset to a Base Unit 7.2.1. Deregistering a Cordless Handset 7.3. Copying Phonebook Entries You can copy phonebook entries from the base unit to a cordless handset , and vice versa. Important: • Groups (including their names and ringer tones) are not copied.
KX-TG1061M/KX-TG1062M/KX-TGA106M 7.6. Troubleshooting If you still have difficulties after following the instructions in this section, disconnect the base unit’s AC adaptor, then reconnect the base unit’s AC adaptor. Remove the batteries from the cordless handset, and then insert the batteries into the cordless handset...
KX-TG1061M/KX-TG1062M/KX-TGA106M 8 Service Mode 8.1. Engineering Mode 8.1.1. Base Unit...
Page 33
KX-TG1061M/KX-TG1062M/KX-TGA106M Frequently Used Items (Base Unit) ex.) Items Address(*1) Default Data New Data Remarks Frequency 00 01~00 02 50 03 Use these items in a READ-ONLY mode to confirm the contents. Careless rewriting may cause serious 00 10~00 14 Given value damage to the system.
Page 35
KX-TG1061M/KX-TG1062M/KX-TGA106M Frequently Used Items (Cordless Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Battery Low 00 04 (*2) Frequency 00 01~00 02 70 02 00 10~00 14 Given value Note: (*1) When you enter the address or New Data, please refer to the table below.
8.2. Copying Phonebook Items when Repairing You can copy the base unit (Maximum number of contacts is 100.) phonebook to another (compatible Panasonic) cordless handset. This will help to save the original phonebook data which the customer has registered. * You cannot copy the base unit phonebook to another base unit.
Page 37
KX-TG1061M/KX-TG1062M/KX-TGA106M Note: • BS=Base Unit , CH=Cordless Handset • If the max number of Cordless Handsets are already registered to the base unit, a new Cordless Handsets cannot be registered. • To register the Cordless Handsets, refer to Registering a Cordless Handset to a Base Unit (P.27) •...
KX-TG1061M/KX-TG1062M/KX-TGA106M 8.3. How to Clear User Setting Units are reset to the Factory settings by this operation (Erase recorded voice messages, stored Phone numbers, Caller list and etc.) Note: • Some menus are not reset. Refer to Operating Instructions (P.22).
KX-TG1061M/KX-TG1062M/KX-TGA106M 9 Troubleshooting Guide 9.1. Troubleshooting Flowchart Flow Chart Cross Reference: Check Caller ID (P.48) Check Power (P.40) Check TAM Operation (P.50) Bell Reception (P.49) Check SP-phone Transmission (P.50) Check Battery Charge (P.41) Check SP-phone Reception (P.50) Check Link (P.42) Check the RF part (P.46)
Page 40
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.1. Check Power 9.1.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (*1) Cross Reference: Note: Power Supply Circuit (P.10) (*1) Refer to Specifications (P.6) for part number and sup- ply voltage of AC adaptor. 9.1.1.2. Cordless Handset Cross Reference: Power Supply Circuit/Reset Circuit (P.14)
Page 42
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.3. Check Link 9.1.3.1. Base Unit Cross Reference: Power Supply Circuit (P.10) Check Point (Base Unit) (P.51) Note: (*1) Refer to Troubleshooting by Symptom (Base Unit and Charger Unit) (P.51).
Page 43
KX-TG1061M/KX-TG1062M/KX-TGA106M Cross Reference: Check Point (Base Unit) (P.51)
Page 44
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.3.2. Cordless Handset Cross Reference: Power Supply Circuit/Reset Circuit (P.14) Check Point (Cordless Handset) (P.55) Note: (*1) Refer to Troubleshooting by Symptom (Cordless Handset) (P.55).
Page 45
KX-TG1061M/KX-TG1062M/KX-TGA106M Cross Reference: Check Point (Cordless Handset) (P.55)
Page 46
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.4. Check the RF part 9.1.4.1. Finding out the Defective part After All the Checkings or Repairing 1. Re-register the checked Cordless Handset to the checked Base Unit, and Regular CH to Regular BU. Note: If you need to register a Cordless Handset, refer to Registering a Cordless Handset to a Base Unit (P.27)50...
Page 47
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.4.2. RF Check Flowchart Each item (1 ~ 4) of RF Check Flowchart corresponds to Check Table for RF part (P.48). Please refer to the each item. Note: (*1) Base unit - refer to (H) of Check Point (Base Unit) (P.51)
Page 48
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.4.3. Check Table for RF part Item BU (Base Unit) Check CH (Cordless Handset) Check Link Confirmation Normal 1. Register Regular CH to BU (to be 1. Register CH (to be checked) to Regular checked). (*1) BU. (*1) 2. Press [Talk] key of the Regular HS to 2.
Page 49
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.8. Bell Reception 9.1.8.1. Base Unit 9.1.8.2. Cordless Handset Cross Reference: Telephone Line Interface (P.11) Check Link (P.42) How to Check the Cordless Handset Speaker or Receiver (P.75)
Page 50
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.1.9. Check TAM Operation Cross Reference: Power Supply Circuit (P.10) Note: (*1) When replacing FLASH MEMORY (IC541), TAM data needs to be written to it. Refer to Base Unit (P.72) of Things to Do after Replacing IC. 9.1.10. Check SP-phone Transmission Cross Reference: Signal Route (P.16)
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.2. Troubleshooting by Symptom (Base Unit and Charger Unit) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on wether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail.
Page 52
KX-TG1061M/KX-TG1062M/KX-TGA106M Items Check Procedure Check or Point Replace Parts (I)* Hookswitch Check with 1. Connect TIP/RING (Telephone Socket) to Tel-simulator which is connected P101,D101, with 600 Ω. DC Characteristics Q111,Q112, 2. Set line voltage to 48 V and line current to 40 mA at off-hook condition of nor- R110,R111, mal telephone.
Page 53
KX-TG1061M/KX-TG1062M/KX-TGA106M Items Check Procedure Check or Point Replace Parts Audio Check (Through Cordless handset) P101,D101, 1. Link with cordless handset. Q111,Q112, 2. Input -45 dBm/1kHz to MIC of cordless handset. R110,R112, Measure the Level at Line I/F and distortion level.
Page 54
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.2.2. Check Point (Charger Unit) Items Check Procedure Check or Point Replace Parts 1. Connect Charge Contact 10 Ω/2 W resistor between charge+ and charge-. Charging Check 2. Measure and confirm voltage across the resistor is 3.1 V ± 0.3 V.
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.3. Troubleshooting by Symptom (Cordless Handset) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail.
Page 56
KX-TG1061M/KX-TG1062M/KX-TGA106M Items Check Procedure Check or Point Replace Parts (F)* Battery Monitor Check 1. Apply 2.25 V between BATT+ and BATT-. IC1, F1, C1, 2. Execute the command R12, R45 sendchar PAD sendchar LED 0 sendchar CRX 0 1 sendchar AD1 It assumes that the return value is XX.
Page 57
KX-TG1061M/KX-TG1062M/KX-TGA106M Items Check Procedure Check or Point Replace Parts (K)* Frequency Offset Confir- Follow steps 1 to 3 of (I). IC1, mation 4.Confirm that the frequency Offset is < ± 50 kHz. C802~C806, C808~C814, C819~C820, C822, C825~C827, C834, C859~C864, L801~L804,...
Page 58
KX-TG1061M/KX-TG1062M/KX-TGA106M 9.3.2. Troubleshooting for Speakerphone When the customer’s telephone line corresponds to the following conditions, and the transmission signal of SP-Phone is inter- rupted, performing the next set up to a cordless handset will improve it to some extent. Conditions 1.
KX-TG1061M/KX-TG1062M/KX-TGA106M 11 Measurements and Adjustments This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in Troubleshooting Guide (P.39) 11.1. Equipment Required • Digital multi-meter (DMM): it must be able to measure voltage and current.
Page 66
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.2.2. How to install Batch file into P.C. Note: • “****” varies depending on the country or models. 11.2.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.3. Adjustment Standard (Base Unit) When connecting the simulator equipments for checking, please refer to below. 11.3.1. Bottom View 0.22uF 6.3 V 47 F SP_PHONE_Receiver 6.3 V 47 F Corde-Handset MIC DCINP (+6.5V) DCINM (GND) Corded-Handset Receiver SPI_DO SPI_CLK...
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.4. Adjustment Standard (Charger Unit) When connecting the simulator equipment for checking, please refer to below. 11.4.1. Bottom View Digital Volt Meter /2 W DC POWER DC 6.5 V Note: (A) is referred to Check Point (Charger Unit) (P.54)
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.5. The Setting Method of JIG (Cordless Handset) This section explains the PC setting to use command required in Check Point (Cordless Handset)(P.55). <Preparation> • Serial JIG cable: PQZZ1CD300E • PC which runs in DOS mode • Batch file CD-ROM for setting: PNZZTG1061M 11.5.1.
Page 70
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.5.2. How to install Batch file into P.C. Note: • “*****” varies depending on the country or models. 11.5.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of FLASH Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.6. Adjustment Standard (Cordless Handset) When connecting the simulator equipments for checking, please refer to below. 11.6.1. Component View Note: (A) - (R) is referred to Check Point (Cordless Handset) (P.55)
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.7. Things to Do after Replacing IC or X'tal If repairing or replacing BBIC (FLASH type), EEPROM and X'tal, it is necessary to download the required data such as Program- ming data or adjustment data, etc in memory. The set doesn't operate if it is not executed.
Page 73
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.7.1.2. Cordless Handset First, operate the PC setting according to The Setting Method of JIG (Cordless Handset)(P.69). Then download the appropriate data according to the following procedures. Items How to download/Required adjustment BBIC (FLASH type) Programming data is stored in memory.
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.8. RF Specification 11.8.1. Base Unit Item Value Refer to -. * TX Power 16.5 dBm ~ 20.5 dBm Check Point (Base Unit) (J) Modulation -390±40/+390±40 kHz/div & Modulated Check Point (Base Unit) (K) width 720 kHz Frequency Offset...
KX-TG1061M/KX-TG1062M/KX-TGA106M 11.9. How to Check the Cordless Handset Speaker or Receiver 1. Prepare the digital voltmeter, and set the selector knob to ohm meter. 2. Put the probes at the speaker terminals as shown below. 11.10. Frequency Table (MHz) Ch. (hex)
KX-TG1061M/KX-TG1062M/KX-TGA106M 12.3. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
Page 81
KX-TG1061M/KX-TG1062M/KX-TGA106M 12.3.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TG1061M/KX-TG1062M/KX-TGA106M 12.4. How to Replace the LLP (Leadless Leadframe Package) IC 12.4.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700°F ± 20°F (370°C ± 10°C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 83
KX-TG1061M/KX-TG1062M/KX-TGA106M 12.4.4. How to Install the Shield Case Note: • If you don’t have special tools (ex. Hot air disordering tool), conduct the following operations. • Shield case’s No. : PNMC1013Z 1. Put the shield case. 2. Solder the surroundings.
KX-TG1061M/KX-TG1062M/KX-TGA106M 12.5. How to Replace the LLP (Leadless Leadframe Package) IC 12.5.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700 °F ± 20 °F (370 °C ± 10 °C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 85
KX-TG1061M/KX-TG1062M/KX-TGA106M 12.5.4. How to Install the IC 1. Place the solder a little on the land where the radiation GND pad on IC bottom is to be attached. 2. Place the solder a little on the land where IC pins are to be attached, then place the IC.
KX-TG1061M/KX-TG1062M/KX-TGA106M 13 Schematic Diagram 13.1. For Schematic Diagram 13.1.1. Base Unit (Schematic Diagram (Base Unit_Main)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. The schematic diagrams may be modified at any time with the development of new technology.
Page 93
KX-TG1061M/KX-TG1062M/KX-TGA106M W 0.15mm L 20+/-2mm 3rd layer R807 RXON L801 C827 TP_ANT1 RX_RF C826 *C859 RF_RXn C803 1.5p DA801 RF_RXp W 0.125mm L 7.6mm CP+3.0V Gap 0.125mm W 0.15mm W 0.15mm 1st layer L 5.0mm L 5.0mm 1st layer 1st layer C172 K0.1u...
KX-TG1061M/KX-TG1062M/KX-TGA106M 15 Exploded View and Replacement Parts List 15.1. Cabinet and Electrical Parts (Base Unit) Note: (*1) This cable is fixed by soldering. Refer to How to Replace the Base unit LCD (P.63).
(*1) This cable is fixed by soldering. Refer to How to Replace the Cordless Handset LCD (P.64). (*2) Attach the spacer (No. 122) to the exact location described above. (*3) The rechargeable Ni-MH battery HHR-4DPA is available through sales route of Panasonic.
KX-TG1061M/KX-TG1062M/KX-TGA106M 15.5. Replacement Parts List 1. RTL (Retention Time Limited) Safety Ref. Part No. Part Name & Description Remarks Note: PNJK1055Z KEYBOARD SWITCH, 5KEY The “RTL” marking indicates that its Retention Time is L0DDYD000010 BUZZER Limited. PNBC1005Y1 BUTTON, ERASE ABS-HB...
Page 109
KX-TG1061M/KX-TG1062M/KX-TGA106M Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks (DIODES) R145 ERJ3GEYJ470 D101 B0EDER000009 DIODE(SI) R146 ERJ2GEJ332 3.3k D301 B0JCME000035 DIODE(SI) R147 ERJ3GEYJ472 4.7k D112 MA1Z300 DIODE(SI) R153 ERJ2GEJ121 D117...
Page 110
KX-TG1061M/KX-TG1062M/KX-TGA106M Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R611 ERJ2GE0R00 C243 ECUE1H100DCQ 10p R612 ERJ2GE0R00 C244 ECUE1H100DCQ 10p R617 ERJ2GE0R00 C301 PQCUV1C105KB 1 R618 ERJ2GE0R00 C302 PQCUV1C105KB 1 R619...
Page 111
KX-TG1061M/KX-TG1062M/KX-TGA106M Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks X511 H0J103500033 CRYSTAL OSCILLATOR (*1) PQJC10056X BATTERY TERMINAL MIC1 L0CBAY000016 BUILTIN-MICROPHONE PNKE1027Z1 COVER, EP CAP PNKF1053Z1 CABINET COVER ABS-HB 15.5.1.3. Operational P.C.Board parts...
Page 112
KX-TG1061M/KX-TG1062M/KX-TGA106M Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks ERJ2GEJ102 ECUE1A104KBQ 0.1 ERJ2GEJ122 1.2k ECUE1H100DCQ 10p ERJ2GEJ101 ECUE1A104KBQ 0.1 ERJ2GE0R00 ECUE1H100DCQ 10p ERJ2GEJ100 ECUE1A104KBQ 0.1 ERJ2GEJ332 3.3k ECUE1A104KBQ 0.1 ERJ2GEJ222 2.2k...