Page 1
HD COLOR VIDEO CAMERA EVI-HD7V EVI-HD3V SERVICE MANUAL 1st Edition (Revised 2)
Page 2
Beim Einbau des Geräts ist daher im Festkabel ein leicht zugänglicher Unterbrecher einzufügen, oder das Netzkabel muß mit einer in der Nähe des Geräts befi ndlichen, leicht zugänglichen Wandsteckdose verbunden werden, damit sich bei einer Funktionsstörung die Stromversorgung zum Gerät jederzeit unterbrechen läßt. EVI-HD7V...
Manual Structure Purpose of this manual This manual is the Service Manual of the HD Color Video Camera EVI-HD7V/ HD3V. This manual contains the service overview, adjustments, troubleshooting, circuit description, spare parts, and diagrams (block diagrams and board layouts). Related manuals In addition to this Service Manual the following manuals are provided.
+PSW2.6 x 6 (In this illustration, this screw is indicated as PSW2.6 x 6 (Large).) Part name: Tighten the following screws to the tightening torque as described below. Tightening torque: . BSW M2 x 5: 0.2 ?0.02 N.m . PSW 2.6 x 6: 0.4 ?0.02 N.m EVI-HD7V...
. If the right and left clearances are not even, adjust them by loosening the setscrews of the tilt motor. . When the setscrews of the tilt motor are loosened, tighten them to the tightening torque as described below. Tightening torque: 0.6 ?0.02 N.m EVI-HD7V...
Hook . Check that the convex portion of the front bezel is not placed on the concave portion of the camera cabinet. . Check that the front bezel is securely attached. Concave portions Front bezel Hooks EVI-HD7V...
5. Remove the camera cabinet (lower front). Camera cabinet (lower front) Camera cabinet (lower rear) BSW M2 x 5 PSW2.6 x 6 PSW2.6 x 6 Camera cabinet (lower front) PSW2.6 x 6 6. To install, reverse the removal procedure. EVI-HD7V...
4. Remove the two screws (PSW2.6 x 6) with the lens Camera cabinet (upper) placed horizontally. PSW2.6 x 6 BSW M2 x 5 5. Remove the screw (BSW M2 x 5), then remove the camera cabinet (upper). 6. To install, reverse the removal procedure. PSW2.6 x 6 EVI-HD7V...
Replace the removed tape (A) or Himeron tape (20 x 40) with the new one. Tighten the following screws to the tightening torque as described below. Tightening torque: . BSW M2 x 5: 0.2 ?0.02 N.m . PSW 2.6 x 6: 0.4 ?0.02 N.m EVI-HD7V...
11. Disconnect the fl exible fl at cable from the connector (CN701) on the DD-316 board. Coaxial CN403 harness 12. To install, reverse the removal procedure. CN701 Flexible DD-316 flat cable board Ferrite core Himeron tape (20 x 40) EVI-HD7V...
. When attaching the wide conversion lens, tighten it Portion A to the tightening torque as described below. Tightening torque: 2 N.m . After attaching the wide conversion lens, check that there is no loosening and rattling. EVI-HD7V...
. When attaching the DC fan, place it with the label Holes side upward. . Check that the two hooks of the fan spring are securely attached as shown in Fig. 1. Connector DD-316 board Fig. 1 Hooks Fan spring EVI-HD7V...
When attaching the FP-234 fl exible wiring board, place it under the VC-576 board as shown in Fig. 2. FP-234 flexible wiring board Fig. 1 Fig. 2 Tape (A) VC-576 board Ferrite core FP-234 flexible wiring board Himeron tape (20 x 40) 1-11 EVI-HD7V...
Page 18
8. Disconnect the two fl exible wiring boards from the Flexible connectors (CN301 and CN851) on the DD-316 board, wiring board then remove the DD-316 board. 9. To install, reverse the removal procedure. CN851 DD-316 board M2 x 5 CN301 Flexible wiring board 1-12 EVI-HD7V...
10. Remove the two screws (PTP2 x 5), then remove the CMOS board assembly. Camera chassis Coaxial harness B1.7 x 3.5 PTP2 x 5 Connector Heat radiation CMOS board rubber assembly 11. To install, reverse the removal procedure. 1-13 EVI-HD7V...
1. Remove the four screws (B2.6 x 6) and the two con- nector screws, then remove the rear panel. 2. Remove the six screws (B2.6 x 6), then remove the bottom plate. Front side of main unit Rear panel B2.6 x 6 Connector screws Bottom plate B2.6 x 6 1-14 EVI-HD7V...
Page 21
PSW2.6 x 6 (Large) pinch the fl exible fl at cable and harness. Flexible S shield plate Tapes (A) flat cable Coaxial cable Earth cable SY-359 board Flexible flat cables Front side of main unit Hole of chassis 1-15 EVI-HD7V...
2. Disconnect the fl exible fl at cable from the connector (CN101) on the SE-987 board. PSW2.6 x 6 (Large) Flexible 3. Remove the screw, then remove the SE-987 board. flat cable SE-987 board CN101 4. To install, reverse the removal procedure. Front side of main unit 1-16 EVI-HD7V...
6. Disconnect the two fl exible fl at cables from the con- MDR-42 board nectors (CN501 and CN502) on the MDR-42 board. 7. Remove the two screws, then remove the MDR-42 board. PSW2.6 x 6 CN502 8. To install, reverse the removal procedure. CN501 Flexible flat cables 1-17 EVI-HD7V...
9. Pull out the earth cable and coaxial harness from the hole of tilt reel and the hole of shaft assembly. 10. Remove the three screws, then remove the shaft as- sembly. Ferrite bead Tilt reel Hole Shaft assembly Hole BTP2.6 x 8 Front side of main unit 1-18 EVI-HD7V...
Page 25
Earth cable FFC retainer (upper). Hook FFC retainer (upper) BTP2.6 x 8 Front side of main unit FFC retainer Flexible flat cable (22, 26) Coaxial harness FFC retainer Earth cable FFC retainer (upper) Flexible flat cable (22, 26) 1-19 EVI-HD7V...
Page 26
fl exible fl at cables (22, 26) from the two holes of tilt chassis assembly. CN501 Tilt stand portion MDR-42 board Coaxial cable Earth cable Flexible flat Flexible cable (22, 26) flat cable 2.6 x 6 (22, 26) BTP2.6 x 8 Tilt chassis assembly Hole BTP2.6 x 8 Holes 1-20 EVI-HD7V...
Page 27
26. Remove the tape (A), then pull out the two fl exible fl at cables (22, 26) from the hole of FFC cover. Flexible flat cable 27. To install, reverse the removal procedure. FFC cover Hole FFC reel Front side of main unit 1-21 EVI-HD7V...
6. Remove the two screws (BTP2.6 x 8). Connector 7. Disconnect the fl exible fl at cable from the connector on the tilt motor, then remove the tilt motor. Flexible flat cable 8. To install, reverse the removal procedure. 1-22 EVI-HD7V...
4. Remove the camera cabinet (upper). (Refer to Section 1-2-4.) 5. Remove the camera block assembly. (Refer to Section 1-3-1.) 6. Remove the SY-359 board. (Refer to Section 1-4-4.) 7. Remove the fl exible fl at cable (22, 26). (Refer to Section 1-5.) 1-23 EVI-HD7V...
. The ordinary soldering iron can be used but the iron tip has to be applied to the solder joint for a slightly longer time. The printed pattern (copper foil) may peel away if the heated tip is applied for too long, so be careful. 1-24 EVI-HD7V...
Page 32
. Digital voltmeter . Waveform monitor . HD monitor . Control software EVI-HD1 Test Program For obtaining this software, please contact your local Sony Sales Offi ce/Service Center. . Personal computer (PC) CPU: Pentium III, 1 GHz or more RAM capacity: 256 MB or more...
22-pin flexible flat cable 75 Z termination (J-6433-730-A) Waveform monitor AC adapter (MPA-AC1, supplied with this unit) (1-468-626-67) HD camera image Power code producing tool RS-232C cross cable (1-790-732-32) (1-857-551-11) (commercial available products) Remote commander RM-95 (J-6082-053-B) Personal computer EVI-HD7V...
The control system of the camera is adjusted using the software installed in a PC (personal computer). Name of the software EVI-HD1 Test Program For obtaining this software, please contact your local Sony Sales Offi ce/Service Center. PC to use The PC in which Microsoft Windows 2000/XP/Vista operates.
fi gure. Use the non-refl ecting and non-glazing vellum paper whose size is more than A0, and make the boundary between white and black to be smoothly fl at. EVI-HD7V...
2. Precautions upon using the remote commander RM-95 Mishandling of the remote commander RM-95 may erase the correct adjustment data at times. To prevent this, it is recommended that all adjustment data be noted down before beginning adjustments and new adjustment data after each adjustment. EVI-HD7V...
1. Set the switch (S1010) of the HD camera image producing tool to 9. 2. Press the RESET button (S1003) of the HD camera image producing tool. Setting to PAL (50i) is completed. S1010 Position 1 Position 9 Reset switch (S1003) HD camera image producing tool EVI-HD7V...
(Example) In the case that the DDS display and the remote commander RM-95 display are BD (). As the upper digit of the hexadecimal notation is B (), and the lower digit is D (), the intersection “189” of the and in the above table is the decimal notation to be calculated. EVI-HD7V...
Page 42
By this data setting, the page 6E can be selected. After the data reading/writing fi nished, return the data on page:0, address:10 to “00”. Address Initial value Remark NTSC AWB standard data input (Refer to Section 2-3-10.) AWB Adjustment (Refer to Section 2-3-12.) 2-12 EVI-HD7V...
Page 43
Address Initial value Remark NTSC AWB Adjustment (Refer to Section 2-3-12.) Color Reproduction Adjustment (Refer to Section 2-3-14.) 40 to FF Fixed data 2-13 EVI-HD7V...
Page 44
F Number and ND Light Quality Correction (Refer to Section 2-3-8.) LV Standard Data Input (Refer to Section 2-3-11.) Max Gain Adjustment (Refer to Section 2-3-19.) Fixed data-1 (Initialized data) PCGM Standard Data Input (Refer to Section 2-3-16.) 2-14 EVI-HD7V...
Page 45
Frange Back Adjustment (Refer to Section 2-3-4.) Fixed data-1 (Initialized data) MR Adjustment (Refer to Section 2-3-2.) 66 to 75 Fixed data-1 (Initialized data) 8C to B7 Fixed data-1 (Initialized data) Image Sensor Output 2ch Matching Adjustment (Refer to Section 2-3-3.) 2-15 EVI-HD7V...
Page 46
Address Initial value Remark NTSC Image Sensor Output 2ch Matching Adjustment (Refer to Section 2-3-3.) 2-16 EVI-HD7V...
If reading/writing data on page 6F, set data:06 to page:0, address:10, and then select page F. By this data setting, the page 6F can be selected. After the data reading/writing fi nished, return the data on page:0, address:10 to “00”. 2-17 EVI-HD7V...
Page 48
Check that the IRIS displayed data satisfi ed the specifi cation 3. Press the PAUSE button. Check that the IRIS displayed data satisfi ed the specifi cation 4. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. 2-18 EVI-HD7V...
(6F) value 3. *1: The adjustment data will be automatically input to page:6F, address:58, 5A to 65. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. Press the PAUSE button. Press the PAUSE button. 2-19 EVI-HD7V...
Subject: Siemens star chart Measuring equipment: Remote commander RM-95, fl ange back adjustment tool Adjustment page: Adjustment address: 11, 48 to 58 Specifi cation: Data of page:6F, address:57 is “00” to “09”. Data of pege:6, address:0C is “00”. 2-20 EVI-HD7V...
Page 51
*1: The adjustment data will be automatically input to page:6F, address:11, 48 to 58. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. Press the PAUSE button. Press the PAUSE button. Perform “Flange Back Check”. (Refer to Section 2-3-6 or 2-3-7.) 2-21 EVI-HD7V...
Press the PAUSE button. (*1) Check that the data changes to “01”. Check that the data is “00”. Check that the data is “00” to “09”. (6F) *1: The adjustment data will be automatically input to page:6F, address:11, 48 to 58. 2-22 EVI-HD7V...
Page 53
. Don’t touch the zoom lever during adjustment. Preparations before adjustments: 1) Set the zoom lens to the TELE end and expose a subject that is more than 500 m away. (subjects with clear contrast such as building, etc.) 2-23 EVI-HD7V...
Page 54
*1: The adjustment data will be automatically input to page:6F, address:48 to 58. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. Press the PAUSE button. Press the PAUSE button. Perform “Flange Back Check”. (Refer to Section 2-3-6 or 2-3-7.) 2-24 EVI-HD7V...
Operation Shoot the chart with the zoom TELE end. Check that the lens is focused. Shoot the chart with the zoom WIDE end. Check that the lens is focused. Procedure after completing adjustment Order Page Address Data Operation 2-25 EVI-HD7V...
Turn on the auto focus. Check that the lens is focused. Shoot the Siemens star chart with the zoom WIDE end. Observe the HD monitor and check that the lens is focused. Procedure after completing adjustment Order Page Address Data Operation 2-26 EVI-HD7V...
3. Input the following data to page:6F, address:1C to 29. Press the PAUSE button of the remote commander RM-95 each time to set data. Address Data NTSC 4. Select page:0, address:10, and set data:00. 5. Select page:0, address:01, and set data:00. 2-27 EVI-HD7V...
In the following adjustment, if the “All white frame” is used, adjust the clear chart to this position. Procedure after completing adjustment Reset the data setting after the adjustment fi nished. Order Page Address Data Operation Press the PAUSE button. 2-28 EVI-HD7V...
Press the PAUSE button. (*1) Check that the data changes to “01”. *1: The adjustment data will be automatically input to page:6E, address:00 to 0F. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. 2-29 EVI-HD7V...
Check that the data changes to “01”. Check that the displayed data satisfi ed the specifi cation. *1: The adjustment data will be automatically input to page:6F, address:2A, 2B. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. 2-30 EVI-HD7V...
Check that the data changes to “01”. *1: The adjustment data will be automatically input to page:6E, address:10 to 1F. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. Remove the color temperature correction fi lter C14 on the lens. 2-31 EVI-HD7V...
XH or YH data How to reset the zoom and focus when they deviated If the zoom and focus deviated due to some reason, reset them in the following method. Order Page Address Data Operation Press the PAUSE button. 2-32 EVI-HD7V...
Page 63
2. Vertical period E = F = 0 A = B C = D Check on the HD monitor (Underscanned mode) A = B C = D E = F = 0 Color-bar chart HD monitor picture frame picture frame 2-33 EVI-HD7V...
Set the bit value of bit0 is “0”, and press the PAUSE button. (66) Press the PAUSE button. NTSC model only Press the PAUSE button. (*1) Check that the data changes to “01”. *1: The adjustment data will be automatically input to page:6E, address:20 to 3F. 2-34 EVI-HD7V...
PAUSE button. 4. The right four digits of the page:1 displayed data of the remote commander RM-95. 1: XX:XX Displayed data When bit15 of the display data is “1”, the display data is “8000” to “FFFF”. 2-35 EVI-HD7V...
Page 66
Order Page Address Data Operation NTSC model only NTSC model only (6F) Set data noted down at step 6, and press the PAUSE button. NTSC model only Press the PAUSE button. Press the PAUSE button. NTSC model only 2-36 EVI-HD7V...
3. Input the data to page:6F, address:2E to 3F. Press the PAUSE button of the remote commander RM-95 each time to set data. Address Data NTSC 4. Select page:0, address:10, and set data:00. 5. Select page:0, address:01, and set data:00. 2-37 EVI-HD7V...
Check that the displayed data satisfi ed the specifi cation. Remove the ND fi lter 1.5 (1.0 + 0.4 + 0.1) on the lens. When bit15 of the display data is “1”, the display data is “8000” to “FFFF”. 2-38 EVI-HD7V...
Press the PAUSE button. (6B) In the following adjustment, if the “Center frame” is used, adjust the clear chart to this position. A clear chart must be shot in larger size than central nine grids. 2-39 EVI-HD7V...
If the data is as follows, go to step 13. . NTSC model: 5B-61 . PAL model: 7B-8A Set the following data. . NTSC model: 5A . PAL model: Check that the data changes to “01”. *1: The adjustment data will be automatically input to page:6F, address:2C. 2-40 EVI-HD7V...
Press the PAUSE button. (6B) Press the PAUSE button. Check that the data changes to “01”. Check that the data is “00”. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. Press the PAUSE button. (6B) 2-41 EVI-HD7V...
Check that the data is “04”. Press the PAUSE button. (6B) Press the PAUSE button. Check that the data changes to “01”. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. Press the PAUSE button. (6B) 2-42 EVI-HD7V...
. Check that the data of page:0, address:10 is “00”. . Check that the data of page:6, address:02 is “00”. If not, select page: 6, address: 01, set data: 00, and press the PAUSE button. . Shoot the clear chart with the zoom TELE end. 2-43 EVI-HD7V...
Page 74
Press the PAUSE button. (69) Press the PAUSE button. Check that the data changes to “01”. Procedure after completing adjustment Order Page Address Data Operation Press the PAUSE button. Press the PAUSE button. Press the PAUSE button. (69) 2-44 EVI-HD7V...
. Transmission at 81090002FF (Inquiry of model name and version) Command of 90500001508pqrs02FF or 90500001509pqrs02FF is returned to Response Window. “pqrs” represents the version number. (Example: 0101 = Ver. 1.01) 2-45 EVI-HD7V...
(4) Transmission at 81010609FF (Adjustment starts) Command of 9041FF is returned to Response Window. After this, pan and tilt operate automatically, and then DC level and amplitude of a MR sensor, and positions of a reset sensor and mechanical termination point are measured. 2-46 EVI-HD7V...
Page 77
= Tilt reset sensor (low) position 90 50 0p 0q 0r 0s FF Data 10 pqrs = Tilt mechanical termination point distance 90 51 xx FF Completion xx = Error code (Refer to Table 2) Table 1 Pan and tilt adjustment 2-47 EVI-HD7V...
Page 78
Incorrect distance between bottom sensor and Home position Incorrect distance between bottom sensor and top termination . EEPROM failure EEPROM Write failure . EEPROM communication failure error Read failure/Abnormal data Table 2 Error code table of pan and tilt adjustment 2-48 EVI-HD7V...
Page 79
When an error code other than 0h appears, it is caused by the adjustment operation failure or abnor- mal camera condition. If required, perform repair and readjustment. When turn off the power once, repeat the above steps (1) to (4). 2-49 EVI-HD7V...
01h: Large torque load applying in stop position When the required time, maximum speed or error code is abnormal, it may be caused by failure of the motor or motor drive circuit (insuffi ciency of torque), or pan rotating mechanism (large friction) etc,. 2-50 EVI-HD7V...
Page 81
(Unit: 12.8 msec) 90 50 0p 0q 0r 0s FF Data 2 pqrs=Maximum speed (Unit: 0.34 deg/sec) 90 51 xx FF Completion xx=Error code 01: Large torque load Table 5 Pan and tilt high speed operation test 2-51 EVI-HD7V...
Page 82
Confi rm that the following items are in normal condition. . Minimum speed: More than 0005h . Maximum speed: Less than 0017h . Speed dispersion value: Less than 0230h These data show the level of speed variation (shaking rate). When abnormal condition occurs, replace a tilt motor. 2-52 EVI-HD7V...
Perform the adjustment from step (1) again. Check that the video output is muted until the initialization of Pan/Tilt is completed. If the video output is blue-back, the above “receiving of adjustment command disabled” is not transmitted. (4) Return each setting to the user setting. 2-53 EVI-HD7V...
. The manufacture date is the date when this product is manufactured. It is different from the date when this product is purchased. . When nothing is displayed on Response Window after the command is sent (message is not returned), check the connection of cable and the camera condition. 2-54 EVI-HD7V...
Is the connection of Is the video output FFC between the Replace FFC. blue-back? camera block and the SY-359 board normal? Transmit “receiving of adjustment command Connect FFC correctly. disabled”. Go to A. (Refer to Section 2-4-4.) (page 3-3) EVI-HD7V...
Page 87
When replacing the MDR-42 board, Check that there is no perform the Pan/Tilt adjustment. foreign substance stuck Replace the Tilt motor. in the moving portion of (Refer to Section 1-6.) cabinet and so on. When replacing the Tilt motor, perform the Pan/Tilt adjustment. EVI-HD7V...
Pan/Tilt adjustment. pin 3 of CN1006 on (Refer to Section 1-4-4.) (Refer to Section 2-4.) the SY-359 board? In the case of the daisy chain connection, check CN1005 on the SY-359 board and if required, replace it. EVI-HD7V...
Pan/Tilt adjustment. abnormal state, replace the blink during the IR (Refer to Section 2-4.) battery. If the trouble persists, remote control replace the SY-359 board. operation? (Refer to Section 1-4-4.) Replace the SY-359 board. (Refer to Section 1-4-4.) EVI-HD7V...
DVI signal using an HDMI/DVI driver circuit. An analog output signal is converted into a component signal or GBR signal using a three-channel VIDEO DAC circuit. Both the converted signals are output from the DVI-I connector to the outside. EVI-HD7V...
FG amplifi er, and a photo-interrupter that detects the reference position of tilt operation. The MDR-42 board is connected with the SY-359 board using a 26-pin fl exible fl at cable. EVI-HD7V...
Therefore, specifi ed parts should be used in the case of replacement. 2. Standardization of Parts Some repair parts supplied by Sony differ from those used for the unit. These are because of parts common- ality and improvement. 3. Stock of Parts Parts marked with “o”...
3-669-607-91 s +PSW (SMALL ROUND) (2.6) 4-151-903-02 s CABINET (LOWER REAR), CAMERA 3-863-696-11 s +BSW M2 (For EVI-HD3V(UC)/HD3V(CE)) 4-151-900-02 s BEZEL, FRONT 4-151-903-12 s CABINET (LOWER REAR), CAMERA (For EVI-HD7V(UC)/HD7V(CE)/ (For EVI-HD7V(UC)/HD7V(CE)) HD3V(UC)/HD3V(CE)) 4-151-903-21 s CABINET (LOWER REAR), CAMERA 4-151-900-11 s BEZEL, FRONT (For EVI-HD7V/B(UC))
Page 95
1-678-019-21 s PWB, FP-234 FLEXIBLE 3-863-696-11 s +BSW M2 1-787-894-11 s FAN, DC (17 SQUARE) 3-080-272-01 s TAPE (A) 1-788-292-11 s OPTICAL FILTER BLOCK OFB-03-22 1-788-555-11 s LENS, WIDE CONVERSION 1-964-390-21 s HARNESS (CD-122) 7-685-534-14 s SCREW +BTP 2.6X8 TYPE2 N-S EVI-HD7V...
Page 96
A-1735-208-A s MOUNTED CIRCUIT BOARD, MDR-42 1-831-685-11 s CABLE, FLEXIBLE FLAT (16 CORE) 3-669-607-91 s +PSW (SMALL ROUND) (2.6) 3-701-507-01 s SET SCREW, DOUBLE POINT,(M3X5) 8-835-740-12 s MOTOR, DC SPZ12A/C-NP 3-080-272-01 s TAPE (A) 7-685-534-14 s SCREW +BTP 2.6X8 TYPE2 N-S EVI-HD7V...
Page 97
1-837-006-11 s CABLE, FLEXIBLE FLAT (22,26) 8-835-917-01 s MOTOR, DC SPZ15B/C-NP 1-966-790-11 s HARNESS, SUB (WIRE, GROUND) 1-966-793-11 s HARNESS, SUB (COAXIAL) 7-621-759-45 s +PSW, 2.6X6 3-080-272-01 s TAPE (A) 7-621-770-67 s SCREW +B 2.6X6 7-685-534-14 s SCREW +BTP 2.6X8 TYPE2 N-S EVI-HD7V...
1-112-915-11 s CAP, NIOBIUM ELECT 22MF 105 ------------ SY-359 BOARD CN501 1-573-366-61 s CONNECTOR, FFC/FPC (ZIF) 26P ------------ CN502 1-573-356-61 s CONNECTOR, FFC/FPC (ZIF) 16P *1:[EVI-HD7V] IC501 6-706-491-01 s IC TC7SH86FU(T5RSOYJF) *2:[EVI-HD3V] IC502 6-706-491-01 s IC TC7SH86FU(T5RSOYJF) IC503 6-706-491-01 s IC TC7SH86FU(T5RSOYJF) Ref.
Page 101
Mode Normal Operation DC/DC CONVETER Micon Emulate Mode DVI HPD Normal Mode DVI HPD Test Mode BLOCK +2.5V MICOM Debug from VISCA OUT S1001 CN1901 DC IN (10.2~14.0V) MICON PGM from VISCA OUT DC12V IN +1.8V +1.2V -3.3V Overall EVI-HD7V...