KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 1 Safety Precautions 1.1. For Service Technicians • Repair service shall be provided in accordance with repair technology information such as service manual so as to prevent fires, injury or electric shock, which can be caused by improper repair work. 1.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 2.2.1. Suggested PbF Solder There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper (Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other materials.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 3 Specifications Note: • Design and specifications are subject to change without notice. Note for Service: • Operation range: Up to 300 m outdoors, Up to 50 m indoors, depending on the condition. • Analog telephone connection: Telephone Line...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 4.2. Circuit Operation (Base Unit) 4.2.1. Outline Base Unit consists of the following ICs as shown in Block Diagram (Base Unit) (P.7). • DECT BBIC (Base Band IC): IC7 - Handling all the audio, signal and data processing needed in a DECT base unit - Controlling the DECT specific physical layer and radio section (Burst Module Controller section) - ADPCM code filter for speech encoding and speech decoding (DSP section) - Echo-cancellation and Echo-suppression (DSP section)
Page 9
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 4.2.2. Power Supply Circuit The power is supplied to the DECT BBIC, RF Module, EEPROM and Charge Contact from AC Adaptor (+6.5 V) as shown in Fig.101. The power supply is as follows; • DECT BBIC (IC7): DC Jack (+6.5 V) → IC2 → IC7 DC Jack (+6.5 V) →...
Page 10
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 4.2.3. Telephone Line Interface <Function> • Bell signal detection • Clip signal detection • ON/OFF hook circuit Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection: In the standby mode, Q3 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the L1T (A) and L1R (B) leads (when the telephone rings), the AC ring voltage is transferred as follows;...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 5 Location of Controls and Components Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server. 6 Installation Instructions Refer to the Operating Instructions. Note: You can download and refer to the Operating Instructions (Instruction book) on TSN Server. 7 Operating Instructions Refer to the Operating Instructions.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 8 Service Mode 8.1. Engineering Mode 8.1.1. Base Unit...
Page 17
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Frequently Used Items (Base Unit) ex.) Items Address Default Data New Data Remarks C-ID (FSK) sensitivity 04 8B 01 (6 dB up) 02 (12 dB up) When hex changes from “00” to “01” or “02”, gain increases by 6 dB or 12 dB. Frequency 00 08/00 07 02/70...
Page 19
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Frequently Used Items (Handset) ex.) Items Address Default Data New Data Possible Adjusted Possible Adjusted Remarks Value MAX (hex) Value MIN (hex) Sending level 03 17 Adjusted value Given value (*2) Receiving level 03 18 Adjusted value Given value (*3) Battery Low 00 04...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 8.2. Copying Phonebook Items when Repairing You can copy the handset phonebook to another (compatible Panasonic) handset. This will help to save the original phonebook data which the customer has registered. Available models: KX-TG2511/KX-TG2512/KX-TG2513 Refer to the following procedures.
Page 21
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Note: • BS=Base Unit, HS=Handset • If the max number of handsets are already registered to the base unit, a new handset cannot be registered. • To register the handset, refer to Registering a Handset to a Base Unit in the Operating Instructions. •...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 8.3. How to Clear User Setting Units are reset to the Factory settings by this operation (Erase recorded, stored Phone numbers, Caller list and etc.) Note: • Some menus are not reset. Refer to Operating Instructions (P.15). • The reset menus differ depending on the following operations. •...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9 Troubleshooting Guide 9.1. Troubleshooting Flowchart Flow Chart Cross Reference: Check Power (P.24) Bell Reception (P.34) Check Battery Charge (P.25) Check Link (P.26) Check the RF part (P.30) Check Handset Transmission (P.33) Check Handset Reception (P.33) Signal Route (P.14) Check Caller ID (P.33)
Page 24
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.1. Check Power 9.1.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (*1) Cross Reference: Note: Power Supply Circuit (P.9) (*1) Refer to Specifications (P.6) for part number and supply voltage of AC Adaptor. 9.1.1.2. Handset Cross Reference: Power Supply Circuit/Reset Circuit (P.12)
Page 25
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.2. Check Battery Charge 9.1.2.1. Base Unit Cross Reference: Charge Circuit (P.12) 9.1.2.2. Handset Cross Reference: Check Power (P.24) Charge Circuit (P.12) 9.1.2.3. Charger Unit Cross Reference: Charge Circuit (P.12)
Page 26
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.3. Check Link 9.1.3.1. Base Unit Note: (*1) Refer to Troubleshooting by Symptom (Base Unit and Charger Unit) (P.35) Cross Reference: Check Point (Base Unit) (P.35) Power Supply Circuit (P.9)
Page 27
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Cross Reference: Check Point (Base Unit) (P.35)
Page 28
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.3.2. Handset Note: (*1) Refer to Troubleshooting by Symptom (Handset) (P.39) Cross Reference: Check Point (Handset) (P.39) Power Supply Circuit/Reset Circuit (P.12)
Page 29
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Cross Reference: Check Point (Handset) (P.39)
Page 30
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.4. Check the RF part 9.1.4.1. Finding out the Defective part After All the Checkings or Repairing 1. Re-register the checked Handset to the checked Base Unit, and Regular HS to Regular BU. Note: If you need to register a handset, refer to Registering a Handset to a Base Unit in the Operating Instructions.
Page 31
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.4.2. RF Check Flowchart Each item (1 ~ 3) of RF Check Flowchart corresponds to Check Table for RF part (P.32). Please refer to the each item. Note: (*1) Base unit - refer to (G) of Check Point (Base Unit) (P.35) Handset - refer to (H) of Check Point (Handset) (P.39)
Page 32
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.4.3. Check Table for RF part Item BU (Base Unit) Check HS (Handset) Check Link Confirmation Normal 1. Register Regular HS to BU (to be 1. Register HS (to be checked) to Regular checked). HS, BU Mode: [Normal mode] 2.
Page 33
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.5. Check Handset Transmission Cross Reference: Signal Route (P.14) 9.1.6. Check Handset Reception Cross Reference: How to Check the Handset Speaker or Receiver (P.57). Signal Route (P.14) 9.1.7. Check Caller ID Cross Reference: Signal Route (P.14)
Page 34
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.1.8. Bell Reception 9.1.8.1. Base Unit 9.1.8.2. Handset Cross Reference: Telephone Line Interface (P.10) Check Link (P.26) How to Check the Handset Speaker or Receiver (P.57)
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.2. Troubleshooting by Symptom (Base Unit and Charger Unit) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail.
Page 36
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Items Check Procedure Check or Point Replace Parts 1. Connect Telephone Socket to Tel-simulator which is connected with 600 Ω. (H)* Hookswitch Check with L1, L2, Q3, R14, DC Characteristics 2. Set line voltage to 48 V and line current to 40mA at off-hook condition of nor- R15, Q4, R16, mal telephone.
Page 37
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Items Check Procedure Check or Point Replace Parts (M)* Frequency Drift Confir- Follow steps 1 to 6 of (J). IC7, mation ANTI_TP 7.Confirm that the frequency drift is < ± 35 kHz/ms. C802~C806, C808~C814, C820, C819, C822, C823, C825, C827, C826, C834, C851, C853, C859~C861,...
Page 38
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Items Check Procedure Check or Point Replace Parts Audio Check 1. Link with Handset which is connected to Line Simulator. IC7, SA1, L1, 2. Set line voltage to 48V and line current to 50mA. L2, D3, Q3, Q4, 3. Input -45dBm(600Ω)/1kHz to MIC of Handset. R14, R15, R16, Measure the Level at Line I/F and distortion level.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.3. Troubleshooting by Symptom (Handset) If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester (*1) or not. Note: (*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic level in detail.
Page 40
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Items Check Procedure Check or Point Replace Parts (F)* Battery Monitor Check 1. Apply 2.25 V between BATT+ and BATT-. IC1, F1, C1, 2. Execute the command sendchar PAD sendchar LED 0 sendchar CRX 0 1 sendchar AD1 It assumes that the return value is XX. a) 6c 71: No need to adjust b) XX: 6A ~ 6B: Need to adjust...
Page 41
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Items Check Procedure Check or Point Replace Parts (K)* Frequency Offset Confir- Follow steps 1 to 3 of (I). IC1, mation 4.Confirm that the frequency Offset is < ± 50 kHz. C802~C806, C808~C814, C819~C820, C822, C825~C827, C834, C860~C864, L801~L804, DA801, R801~R808 (L)* Frequency Drift Confir-...
Page 42
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 9.3.2. Troubleshooting for Speakerphone When the customer’s telephone line corresponds to the following conditions, and the transmission signal of SP-Phone is interrupted, performing the next set up to a cordless handset will improve it to some extent. Conditions 1. When customer’s line has less line loss. ex.) The customer is using optical fiber, ISDN terminal adaptor, or PBX.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 10.2. How to Replace the Handset LCD Note: The illustrations are simplified in this page. They may differ from the actual product.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11 Measurements and Adjustments This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in Troubleshooting Guide (P.23) 11.1. Equipment Required • Digital multi-meter (DMM): it must be able to measure voltage and current. •...
Page 48
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.2.2. How to install Batch file into P.C. Note: • “*****” varies depending on the country or models. 11.2.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.3. Adjustment Standard (Base Unit) When connecting the simulator equipment for checking, please refer to below. 11.3.1. Bottom View VDD4 CP+3.0V VDD5 CP+2.5V VDD3 +3.0V VDD2 +2.4V VDD1 +1.8V CHARGE- CHARGE+ Note: (A) - (S) is referred to Check Point (Base Unit) (P.35)
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.4. Adjustment Standard (Charger Unit) When connecting the simulator equipment for checking, please refer to below. 11.4.1. Bottom View Digital Volt Meter /2 W DC POWER DC 6.5 V Note: (A) is referred to Check Point (Charger Unit) (P.38)
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.5. The Setting Method of JIG (Handset) This section explains the PC setting to use command required in Check Point (Handset)(P.39). <Preparation> (PQZZ1CD505E), change following values • Serial JIG cable: PQZZ1CD300E* resistance. Then you can use it as a JIG Cable for both •...
Page 52
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.5.2. How to install Batch file into P.C. Note: • “*****” varies depending on the country or models. 11.5.3. Commands See the table below for frequently used commands. Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00”...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.7. Things to Do after Replacing IC or X'tal If repairing or replacing BBIC (FLASH type), EEPROM and X'tal, it is necessary to download the required data such as Programming data or adjustment data, etc in memory. The set doesn't operate if it is not executed. 11.7.1.
Page 55
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.7.1.2. Handset First, operate the PC setting according to The Setting Method of JIG (Handset)(P.51). Then download the appropriate data according to the following procedures. Items How to download/Required adjustment BBIC (FLASH type) Programming data is stored in memory. 1) Make sure to connect the JIG cable, then disconnect the DC (IC1) Power in order to download the data.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 11.9. How to Check the Handset Speaker or Receiver 1. Prepare the digital voltmeter, and set the selector knob to ohm meter. 2. Put the probes at the speaker terminals as shown below. 11.10. Frequency Table (MHz) BASE UNIT HANDSET Channel No Transmit Frequency...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 12 Miscellaneous 12.1. How to Replace the Flat Package IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins. 12.1.1.
Page 59
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 12.1.3. How to Install the IC 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC. 3.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 12.2. How to Replace the Shield Case 12.2.1. Preparation • PbF (: Pb free) Solder • Soldering Iron Tip Temperature of 700°F ± 20°F (370°C ± 10°C) Note: We recommend a 30 to 40 Watt soldering iron. An expert may be able to use a 60 to 80 Watt iron where someone with less experience could overheat and damage the PCB foil.
Page 61
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 12.2.4. How to Install the Shield Case Note: • If you don’t have special tools (ex. Hot air disordering tool), conduct the following operations. • Shield case’s No. : PNMC1013Z 1. Put the shield case. 2. Solder the surroundings.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 12.3. Terminal Guide of the ICs, Transistors and Diodes and Electrolytic Capacitors 12.3.1. Base Unit 12.3.2. Handset...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 13 Schematic Diagram 13.1. For Schematic Diagram 13.1.1. Base Unit (Schematic Diagram (Base Unit)) Notes: 1. DC voltage measurements are taken with voltmeter from the negative voltage line. 2. The schematic diagrams may be modified at any time with the development of new technology. 13.1.2.
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 13.2. Schematic Diagram (Base Unit) ANT1_TP ANT2_TP ANT_2 ANT_1 C851 C853 W 0.15mm W 0.15mm L 22+/-4mm L 22+/-4mm 1st or 4th layer 1st or 4th layer DA802 W 0.15mm L 22+/-4mm 1st or 4th layer W 0.15mm L 20+/-2mm Beep C859 3rd layer...
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ 15 Exploded View and Replacement Parts List 15.1. Cabinet and Electrical Parts (Base Unit) 7(*1) 7(*1) PCB1 Ref.No. Figure 2.6 x 8 mm Note: (*1) The SPACERs (No.7) are cut from the excess parts of SPACER (No.108) of Cabinet and Electrical Parts (Handset) (P.75).
(*1) This cable is fixed by welding. Refer to How to Replace the Handset LCD (P.46). (*2) The rechargeable Ni-MH battery HHR-4DPA/2B or HHR-4MRT/2B is available through sales route of Panasonic. (*3) Attach the spacer (No. 119) to the exact location described above.
Safety Ref. Part No. Part Name & Description Remarks 1. RTL (Retention Time Limited) PNBC1303Z1 BUTTON, LOCATOR (for ABS-HB KX-TG2511ALM) Note: PNBC1303Y3 BUTTON, LOCATOR (for ABS-HB The “RTL” marking indicates that its Retention Time is KX-TG2511ALS) (for KX- Limited. TG2512ALS)
Page 79
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks (RESISTORS) ECUV1C104KBV 0.1 PQ4R10XJ184 180k ECUV1C104KBV 0.1 PQ4R10XJ105 F1K2H681A008 680p PQ4R10XJ184 180k F1K2H681A008 680p PQ4R10XJ105 ECUE1A683KBQ 0.068 ERJ3GEYJ565 5.6M ECUV1H272KBV 0.0027 ERJ3GEYJ104 100k PQCUV1A105KB 1...
Page 80
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ (*3) When removing E105, use special tools (ex. Hot air Safety Ref. Part No. Part Name & Description Remarks disordering tool). C858 ECUE1H101JCQ 100p (*4) When replacing the handset LCD, See How to C859 F1G1H100A723 10p Replace the Handset LCD(P.46). C860 F1G1H3R0A480 3p (*5) Backside of this IC has a ground plate.
Page 81
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Safety Ref. Part No. Part Name & Description Remarks Safety Ref. Part No. Part Name & Description Remarks R225 ERJ2GE0R00 C834 F1G1H1R0A480 1p R231 ERJ2GEJ824 820k C860 F1G1H100A723 10p R232 ERJ2GEJ434X 430k C861 F1G1H3R0A480 3p R248 ERJ2GE0R00 (OTHERS) R330 ERJ2GEJ105X MIC100 L0CBAY000032 MICROPHONE R331...
Page 82
KX-TG2511AL/KX-TG2512AL/KX-TG2513AL/KX-TGA250AZ Safety Ref. Part No. Part Name & Description Remarks XTB2+8GFJ TAPPING SCREW 15.5.6. Fixtures and Tools Note: (*1) See Equipment Required (P.47), and The Setting Method of JIG (Handset) (P.51). (*2) When replacing the Handset LCD, See How to Replace the Handset LCD (P.46).