Page 18
仕様 コン ト ロール信号 REMOTE (BNC 型) × 1 S-BUS データ転送方式 BI-PHASE SPACE データ転送速度 312.5 kbps 信号電送距離 500 m (75 Ω同軸ケーブル 5C-2V 使用時) 動作温度 0℃〜 45℃ 電源 AC100〜240 V 、 50/60 Hz 消費電力 10 W 最大外形寸法 424×44×150 mm (幅 / 高さ/ 奥行き) 質量 3 kg 付属品 T 型ブリ ッ ジ (1) キー ト ップ引き抜き治具 (1) キーラベル (1 組) オペレーシ...
Page 19
For the Customers in the United Kingdom WARNING IMPORTANT To prevent fire or shock hazard, do not expose the unit to The wires in this mains lead are coloured in accordance with rain or moisture. the following code: Green-and-yellow: Earth To avoid electrical shock, do not open the cabinet.
Page 20
Phantom Function ........... 8(E) Location and Fucntion of Parts ......9(E) Preparations ............11(E) Settings on the Control Terminal ....11(E) Preparation for the BKS-R1608/3209 ... 11(E) Settings by Using the Buttons (Setup Function) ..............12(E) Operations ............14(E) Specifications ............15(E)
DVS-V3232B or DVS-V6464B and system is also 253. you wish to monitor the input and output signals, you may switch the monitor signals using the BKS-R1608/ Route function to show the expanded sources 3209. Source, destination, and monitor switching is...
Overview Connectable with a single cable Example of Setting the Select The unit can be connected to the Sony routing Button Functions switchers using a single 75-ohm coaxial cable, and can control the switchers. The select buttons can be used as either source select buttons or destination select buttons.
DVS-A3232 Audio Routing switcher Video Routing Routing Switcher Routing Switcher Switcher (S) Source Video Audio BKS-R1607 Time code Level 1 Level 1 BKS-R1608 BKS-R3210 BKS-R1607 BKS-R3209 BKS-R3209 BKS-R3209 max. BKS-R3209 units BKS-R3209 BKS-R3209 BKS-R3209 BKS-R3209 Only one of the REMOTE 1 connectors on a routing switcher used as a secondary station will be active.
Source Destination When the BKS-R3210 is used in combination with the LEVEL 1 IN 11 OUT 3 BKS-R1608/3209, different sources can be switched LEVEL 2 IN 14 OUT 3 for levels. This is called the break-away function. LEVEL 3 IN 16...
Use of Multiple Control Units Route Function When you control the routing switcher using the When you use a switcher B having no cascade function control unit, the number of controllable sources and such as a DVS-7000 and expand the number of sources destinations can be expanded by using multiple BKS- by connecting another switcher A, the source name of R1607/R1608/R3209/R3210 in combination.
Overview Examples of this Phantom are gieven below. Phantom Function Example 1 Assign a source (audio source AUD007 for example) This control unit has three phantom functions; global of a level to multiple sources of another level (video phantom, local phantom, and destination offset local source IN001 and IN005 for example) phantom.
Location and Fucntion of Parts 1 ERROR indicator BKS-R1608 front panel ERROR PROT LOCK BKS-R1608 3 LOCK button/lamp 4 Source/destination select buttons 2 PROT button/lamp 1 ERROR indicator BKS-R3209 front panel ERROR PROT LOCK BKS-R3209 3 LOCK button/lamp 4 Source/destination select buttons...
Page 28
Location and Function of Parts 3 LOCK button/lamp 5 ~AC IN (AC power input) connector Press and light this button, and the buttons on the front Connect to an AC power source using the designated panel other than this button are disabled. This AC power cord.
Settings on the Control Terminal used. Before switching signals with this unit, the following preparations should be made on the control terminal Preparation for the BKS-R1608/ connected to the primary station of the S-BUS data R3209 link. For details on making the settings, refer to the Installation You may use up to 253 units of the control unit, Manual supplied with the routing switcher.
Attaching a key label below. The key labels are supplied with this control unit. Attach the labels to the buttons with the following BKS-R1608 procedure. 10 11 12 13 14 15 16 BKS-R3209...
Page 31
Setting to 8-source/8-destination or 16-source/ 16-destination select mode 1 List of setup operations While holding down buttons 5 and 6, turn the power For the BKS-R1608, the select buttons 1 through 8 Settings Buttons to be pressed work as source select buttons, and the select buttons 9...
Note Press one of the source select buttons to select a source. To switch monitor signals using the BKS-R1608/ R3209, system software that is version 3.10 or above The pressed button lights in bright green, and the should be installed.
100 to 120 V AC (for the U.S.A. and Canada) 100 to 240 V AC, 50/60 Hz (for the other countries) Power consumption BKS-R1608: 0.08 A at 100 V AC (10W) BKS-R3209: 0.11 A at 100 V AC (10W) Peak inrush current...
Page 34
The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any...