HDS-V3232 DIGITAL VIDEO ROUTING SWITCHER DVS-V3232B/V3232M DVS-V6464B/V6464M MULTI BIT RATE ROUTING SWITCHER HDS-X3400/X3600/X3700 16-SOURCE CONTROL UNIT BKS-R1601 X-Y CONTROL UNIT BKS-R3202/R3210/R3220 32-SOURCE CONTROL UNIT BKS-R3203 UNIVERSAL CONTROL UNIT BKS-R3204/R1608/R3209 BKS-R1618/R3219 SOURCE AND DESTINATION CONTROL UNIT BKS-R3205 8-DESTINATION CONTROL UNIT BKS-R3206...
Page 2
IBM and AT are registered trademarks of International Business Machines, Inc. Windows is a registered trademark of Microsoft Corporation. Windows NT is a trademark of Microsoft Corporation. Intel 80486SX is a trademark of Intel Corporation. ROUTING SWITCHER SYSTEM (E)
Manual Structure Purpose of this manual ... 5 Contents ... 5 Related manuals ... 6 DVS-128/HDS-X3000 Series and DVS-V3232M/V6464M ... 8 1. System Overview 1-1. Digital Routing Switcher System ... 1-1 1-2. System Control ... 1-3 1-2-1. Specifications and functions of control port ... 1-3 1-2-2.
Page 4
3. Control Terminal 3-1. Selecting the Control Terminal ... 3-1 3-2. Control Terminal Display ... 3-2 3-3. System Status Screen ... 3-3 3-4. Menu Screen ... 3-4 3-4-1. Menu screen of the primary station ... 3-4 3-4-2. Menu screen of the secondary station ... 3-5 3-4-3.
Page 5
T : SET CLOCK ... 5-20 U : SELECT REMOTE ... 5-21 V : SELECT WARNING DISPLAY ... 5-22 W : SYSTEM STATUS LOG ... 5-23 X : DISPLAY S-BUS COMMUNICATION ... 5-23 Y : DISPLAY TABLE (Except for HDS-V3232) ... 5-24 Z : SET UNIT DETECTABLE ...
Page 6
Z : SET PANEL STATUS (BKS-R1607/R1608/R3204/R3205/R3209/R3210) <MONITOR MENU> ... 5-52 5-5. Backup of Setting Data ... 5-54 5-6. When Data is Lost ... 5-54 5-7. Initialization of Table Data ... 5-55 5-7-1. Initializing Procedure and Corresponding Items ... 5-55 5-7-2. Default Values Initialization ...
ROUTING SWITCHER SYSTEM (E) Manual Structure This is the Installation Manual (software) for the Sony routing switcher system (it is described as “router system” in this manual). It contains information on the initial settings of the software when installing the units making up the digital router system.
This manual contains information on the protocols used for controlling the routing switcher system. The following manuals are available for protocols used to support. Please contact to Sony’s service organization to obtain a copy of the manual. S-BUS PROTOCOL AND COMMAND SPECIFICATIONS (S-BUS remote terminal control protocol)
Page 9
..Maintenance Manual Part 2 (not supplied with the HDS-V3232) This manual contains detailed information on the maintenance and servicing of HDS-V3232 and their parts (board layout, schematic diagram, detailed part list and so on). If this manual is required, please contact to Sony’s service organization.
This manual describes the information that premises the service board parts replacement (board layouts, schematic diagrams and detailed parts list) of the HDS-X3000 series. If this manual is required, please contact your local Sony Sales Office/Service Center. (7) BKS-R3216/R1617/R3219 ..Operation Manual (supplied with each unit) This manual explains the notes on operating, specifications, locations and functions of each unit.
It sets the configuration and operation of the router system. It monitors the system in operation and displays the messages. A unique control protocol called S-BUS (Sony serial bus) is used for controlling the switcher system. With this protocol, all control signals are transmitted by using one 75 Z coaxial cable. The transmission path is called the “S-BUS data link”.
Page 12
When units other than these are used, some terminal displays will be different and some functions cannot be used. Therefore, please contact to Sony’s service organization to upgrade the version of your software. Use the same version software for the same models of routing switcher or remote control units on the S- BUS data link.
1-2. System Control 1-2-1. Specifications and functions of control port The DVS-V3232B/V6464B and HDS-V3232 digital video routing switcher is equipped with four kinds of remote ports REMOTE 1 (S-BUS), REMOTE 2 (9-pin), REMOTE 3 (25-pin), and REMOTE 4 (monitor S-BUS). Other switchers are equipped with three kinds of remote ports excluding REMOTE 4. The specifications and functions of the control ports are as follows.
Page 14
1-2. System Control REMOTE 3 D-sub 25-pin (MODEM side pin arrangement) Protocol RS-232C, 9600 bps , 8bit, No Parity, No check Function With this port the communication between the primary station and the control terminal and the setting of the units are performed. It is recommended that the control terminal be always connected to the switcher set to the primary station, so that you can see error message of the communication circuit and operation condition of units.
1-2-2. S-BUS control The S-BUS control is a remote control system. It has a simple connection structure and provides highly efficient communication. Multiple routing switchers and remote control units are connected to a single bus line to form a control network called the S-BUS data link. The units on this S-BUS data link commu- nicate with each other using the S-BUS protocol, select the necessary data from the control data transmit- ted through the data link, and operate according to the data.
Page 16
1-2. System Control Example of S-BUS control system connection Control Terminal Personal computer with a communication software or Windows 3.1 installed Primary Level 1 REMOTE 3 Station Video Routing Switcher DVS-V64646B Secondary Station Level 2 Maximum 253 units Audio Routing Switcher DVS-A3232 <Audio Channel 1/2>...
1-2-3. 9-pin remote control The Sony digital routing switcher can be controlled from external control units connected to the RE- MOTE 2 (D-sub 9-pin) using RS-422A. For DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232, the functions performed by 9-pin remote control, can especially be upgraded to a great extent. The following three kinds of 9-pin remote protocols can be used.
Page 18
DVS-V3232B DVS- DVS-A3232 DVS-A3232 V6464B : 75 Z terminator : Standard units making up Sony router system : T bridge (M) and (S) mean the setting of M/S switch on the CPU board. Sub Controller (Interface Unit) Status Display Remote Control...
1-2-4. Connection of control terminal Connect the control terminal to the REMOTE3 (D-sub 25-pin) connector of the primary station as shown below. The control terminal is used for setting of the router system and for displaying the information of errors, problems, system status, etc. during operation. Use the personal computer installing the terminal software as the control terminal of the router system.
Page 20
1-2. System Control The following shows one way of connecting the monitor S-BUS system. Secondary Station (S) DVS-V6464B Secondary Station (S) DVS-V6464B (M) (S) : M/S switch setting on the monitor Board. : T Bridge (A) : T Bridge (B) : 75 Z Terminator 1-10 <S-BUS>...
2-1. Main Functions of Router System 1) The routing switcher is equipped with a system controller. It therefore does not require an additional controller for controlling the routing switchers. 2) By the cascade connection, up to 512 x 512 crosspoints can be selected. 3) Up to 8 levels can be assigned.
2-5. Number of Units 2-2. Built-in Controller The Sony digital routing switcher incorporates a system controller and therefore does not require a separate external controller. When several routing switchers are connected to the S-BUS, the CPU of the switcher set as the primary station will control the whole system.
2-6. Protect Function Function which protects the crosspoint set so that it cannot be released using other remote control units. While the protect function is on, the destination of the crosspoint to be protected will be fixed. Once the protect is set, it will not be released by any command, except those from the control terminal and the control unit used to set it.
2-10. Setting the Input/Output Name (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-10. Setting the Input/Output Name (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) The following names can be used for the input/output connectors of the routing switcher. 1. “Type+Number” name 2. ”Description“ name There are altogether three kinds of numbers that can be set as input/output numbers. These are “physical number”, “connector number”, and “virtual number”.
Page 25
The name “Type + Num” consists of four alphabets and three numbers. It is assigned to the virtual number. Sixteen kinds of letters can be set for the “Type” part. Number 1 to 999 can be used for the “Num” part. Examples: CAM 234, VTR 145 The name “Description”...
2-11. Virtual Mapping Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-11. Virtual Mapping Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) Several routing switchers can be mapped on a virtual matrix with 512 inputs and 512 outputs in router system. The matrix of one switcher can be also divided into several virtual levels and mapped. For example, a switcher handling the 4:2:2 video signal and a switcher handling the 4 fsc video signal can be mapped on the same level.
2-12. Free Assignment Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-12. Free Assignment Function (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) While the same input/output number can be assigned, through levels 1 to 8, for each input/output name, different physical number can also be assigned on each level for an input/output name. The following figure shows the case that DVS-V6464B is used for level 1 and DVS-A3232 for levels 2 and 3.
2-13. Monitor Function (BKDS-V3292B only) 2-13. Monitor Function (BKDS-V3292B only) If a DVS-V3232B/V6464B is equipped with the optional BKDS-V3292B, any input/output signal can be monitored. The input and output signals can be observed on different monitors or on the same monitor by switching channels.
Page 29
DVS-V6464B DVS-V6464B 75 Z Terminate DVS-V6464B DVS-V6464B 75 Z Terminate BKS-R3204 BKS-R3204 75 Z Terminate ROUTING SWITCHER SYSTEM (E) DVS-V6464B (P-1) DVS-V6464B 75 Z Terminate DVS-V6464B (P-2) DVS-V6464B DVS-V6464B (P-3) 2-13. Monitor Function (BKDS-V3292B only) BKS-R3204 BKS-R3204 BKS-R3204 BKS-R3206 75 Z Terminate : Standard S-BUS Line : Monitor S-BUS Line...
2-14. Tie Line Management (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) 2-14. Tie Line Management (DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232) If the primary station is a DVS-V3232B/V6464B, BKPF-R70 or HDS-V3232, by previously setting four signal paths between routing switchers, unused signal paths can be selected automatically and protected when input and output names are selected.
Operation example: 1. IN023 and OUT027 are selected from the remote control unit. 2. The CPU of the primary station detects IN023 from the source group. In the example below, the corresponding group is S002. 3. Like for IN023, the CPU also detects OUT027. The corresponding group is D002. 4.
2-16. Self-Diagnosis Function 2-16. Self-Diagnosis Function The routing switcher performed self-diagnosis on the following items and displays the results on the control terminal connected to the primary station. O Presence of board and its sort O Version of ROM on the control board O Presence of backup power supply unit/backup CPU board O Detection of fan rotation O Display of reference signal...
2-17. Route Function One of an application of Router is to expand number of Source inputs for DVS-7000 connecting with DVS-V6464B, show below. Route function is to display a source input chasing from a last program out even performing 4 times Re- entry function with DVS-7000/DME.
2-18. Enhanced Restriction of Selected Block (BKS-R1607/R3210 only) 2-18. Enhanced Restriction of Selected Block (BKS-R1607/R3210 only) If you define a certain number of outputs, you can vary a number of inputs which would not be capable with the older panel. This is applicable with BKS-R1607 and BKS-R3210.
3-1. Selecting the Control Terminal Load Windows 3.1 to an IBM PC/AT compatible machine (CPU: 80486 or a faster and more powerful micro-processor, clock: 25 MHz or faster enough) and use it as a control terminal in the terminal mode of Windows.
3-2. Control Terminal Display 3-2. Control Terminal Display The control terminal display consists of the following three types of screen. . System status screen : It displays messages while the router system is operating. . Menu screen : It displays the menu for setting the router system. .
If the result of the self-diagnosis is satisfactory, “OK” will be displayed at the corresponding item. However if an error has been detected, this item will be the reversal characters. SONY Digital Routing System DVS-V6464B ITEM ROM CHECK SUM...
2. Press the alphabet key assigned to each menu item. The screen will return to the system status screen when [Ctrl] _ [X] pressed. Primary station menu screen of DVS-V3232B/V6464B, BKPF-R70 or HDS-V3232 is as follows. SONY ROUTING SYSTEM SETUP MENU MODIFICATION COMMAND A: DISPLAY CONTROL AREA...
When the secondary station menu is called, the color function will become ineffective, even if [S: SE- LECT INDICATION COLOR] has been selected to “ON”. (1) Routing switcher 1 DVS-V1616 SONY ROUTING SYSTEM SETUP MENU A: SET UNIT LOCATION Y: DISPLAY TABLE Ctrl-D:RETURN Menu Screen of the Secondary Station (Ex.
Page 40
3-4. Menu Screen 3 DVS-RS1616/TC3232/A3232, BVS-V3232/A3232 SONY ROUTING SYSTEM SETUP MENU A: SET UNIT LOCATION K: DEFAULT TABLE Y: DISPLAY TABLE Ctrl-D:RETURN Menu Screen of the Secondary Station (Ex. DVS-RS1616) DVS-TC3232/A3232 and BVS-V3232/A3232 does not have menu item [Z]. 4 HDS-V3232...
Page 41
(2) Remote control unit 1 BKS-R3202 SONY ROUTING SYSTEM SETUP MENU H: SET PHANTOM TABLE N: SET PANEL TABLE O: SET AVAILABLE DESTINATION L: COPY TABLE DATA S: DISPLAY DESCRIPTION NAME Ctrl-D:RETURN Menu Screen of the Remote Control Unit (Ex. BKS-R3202)
Page 42
3-4. Menu Screen 3 BKS-R1607, BKS-R1608, BKS-R3209, BKS-R3210 SONY ROUTING SYSTEM SETUP MENU Å H: SET PHANTOM TABLE N: SET PANEL TABLE O: SET AVAILABLE SOURCE/DESTINATION R: SET ROUTE L: COPY TABLE DATA Z: SET PANEL STATUS S: DISPLAY DESCRIPTION NAME Ctrl-D:RETURN Menu Screen of the Remote Control Unit (Ex.
3-4-3. Menu screen of the primary station on monitor S-BUS To call the menu screen of the primary station on the monitor S-BUS, select menu item [R: CALL SECONDARY STATION] in the primary station menu on the standard S-BUS. (The switcher set as the primary station on the monitor S-BUS.) Next, select menu item [M: SET MONITOR FUNCTION].
Page 44
3-4. Menu Screen (2) Remote control unit 1 BKS-R3202 MONITOR SYSTEM SETUP MENU S: DISPLAY DESCRIPTION NAME Ctrl-Z:RETURN Menu Screen of the Secondary Station on Monitor S-BUS (Ex. BKS-R3202) 2 BKS-R3204, BKS-R3205 MONITOR SYSTEM SETUP MENU N: SET PANEL TABLE L: COPY TABLE DATA Z: SET PANEL STATUS S: DISPLAY DESCRIPTION NAME...
3-5. Setting Screen Set the items in the menu in the setting screen. To call the setting screen, select the menu item with the cursor key or input it using the alphabet key, and press [Enter]. (The same procedure for calling the setting screen is applied to both the primary station menu and secondary station menu.) The screen returns to the menu screen when [Ctrl] _ [E] is pressed at each menu item.
4-1. Outline This setup procedure is written for the setup operator to understand the setup procedure, and more importantly, the philosophy behind the setup. Time spent now, before actually sitting down at the Setup Terminal will greatly enhance the flexibility of your router system (routing switcher system). If your system is only comprised of DVS-V**** routing switchers the setup approach is much simpler, and pretty strait forward.
4-2. Preliminary Information Before Installation 4-2. Preliminary Information Before Installation The control area of each switcher when used as the primary station is as follows. Model Input control area area DVS-V6464B 1 to 512 DVS-A3232 DVS-RS1616 DVS-TC3232 DVS-V3232B 1 to 512 DVS-V1616 BVS-V3232 BVS-A3232...
4-3. Preparation Before Setup 4-3. Preparation Before Setup 1. Set a primary station DVS-V6464B or DVS-V3232B is recommended as the primary station. Set M/S switch on the CPU-149 board to “M” position Station ID automatically will equal one. Set only one primary station. If more than two are set as the primary, they will not work correctly.
4-4. Basic Setup Procedures 4-4. Basic Setup Procedures 1. Identify all in/out signals, and segregate them into 16 types of sources and destinations (1) Make IN/OUT list of each routing switcher Make input/output list of each routing switcher referring to installation, or wiring diagram or other documentation showing router interconnection.
Page 51
VTR 1 VTR 2 VTR 3 VTR 4 VTR 5 VTR 6 VTR 7 VTR 8 Studio A News 1 Satellite 1 Satellite 2 Network 1 Network 2 Remote 1 Remote 2 Camera 1 Camera 2 Camera 3 Camera 4 Still Store 1 Still Store 2 Char Gen 1...
Page 52
4-4. Basic Setup Procedures (2) Assign Name Types (Menu Item [B]) Now select, and enter your 16 source and destination name pre-fixes. Once again, up to 16 type names used for source/destination name are decided using 4 letters (except “;”). Set using the menu item [B : SET SOURCE/DESTINATION TYPE].
Page 53
4-4. Basic Setup Procedures Figure 2 shows that no two levels need to occupy the same size space in the X, and Y directions. As our example in figure 1 demonstrates, level 1 could be 32 by 32 in 2 dimensional X, Y space, while levels 2, and 3 are only 16 by 16.
Page 54
4-4. Basic Setup Procedures Going back to the VTR 1 example, each of the 3 routing switcher outputs (SDI, AES/EBU, and analog audio) could be assigned to a different level, under the VTR001 label. Whenever destination VTR001 was selected all 3 crosspoints in the 3 different routing switchers would switch together.
Page 55
With this approach, you need the control terminal connected to the primary routing switcher, or a control panel that allows access to individual “levels”, like the BKS-R1607, BKS-R1608, BKS-R3209 or BKS- R3210 to control only one level of VTR001 routing. Figure 4 shows this approach.
Page 57
Example : Destinations . Satellite 1 connected to SDI routing switcher OUT 9 (SDI routing switcher given label destinations 001-032) . DAT 1 connected to AES/EBU routing switcher OUT 9 (AES/EBU routing switcher given label destinations 033-048) . Satellite 1 connected to Analog Audio OUT 9 (Analog audio routing switcher given label destinations 049-064) Therefore : SDI Satellite 1...
Page 58
4-4. Basic Setup Procedures With this approach sources, and destinations like the VTR’s would be level mapped together so that all 3 routing switchers switch at the same time under the VTR001, VTR002, etc. label. But in the case of output 11, of each of the 3 routing switchers, the 1, and 3 levels (SDI, and analog audio respectively) would be level mapped and switched together (REM001) while output 11 of level 2, which is DAT003 would be virtually mapped off away from the other 2, so that it could be easily switched on it’s own.
Page 59
VTR 1 VTR 2 VTR 3 VTR 4 VTR 5 VTR 6 VTR 7 VTR 8 Studio A News 1 Satellite 1 Satellite 2 Network 1 Network 2 Remote 1 Remote 2 Camera 1 Camera 2 Camera 3 Camera 4 Still Store 1 Still Store 2 Char Gen 1...
Page 60
4-4. Basic Setup Procedures Now select suitable names for sources/destinations using Type name, and number and enter them in the IN/OUT list of each routing switcher (menu item [C]). Remember that you have to attention to the ins, and outs of routing switchers on all levels when you build this list.
Page 61
3. Set Level Table (Menu Item [E]) This is the step where you assign what levels you want each name or label to be assigned to. You also assign the names of the various levels (here SDI, AES, and AUD are used). The information entered here was derived from figure 7.
Page 62
4-4. Basic Setup Procedures 4. Physical Assignment (Menu Item [L]) Now we actually associate the labels or names to a physical routing switcher input or output. Assign the physical source/destination number and the physical level to the virtual source/destination name and the virtual levels using the menu item [L : SET PHYSICAL ASSIGNMENT].
Page 63
Additionally, an individual routing switcher can be divided in 2, or more virtual routing switchers. This means that one level can be made to look like 2, or more levels. In our example our 3 level routing switcher could have the AES/EBU routing switcher split into 2 virtual levels. Our 3 routing switcher system would now have 4 levels.
Page 64
(control panels) phantoms. Local phantoms may be created in each control panel. Below is an example of a local phantom residing in a control panels phantom table : SONY ROUTING SYSTEM SETUP MENU SET PHANTOM TABLE(PHANTOM:DESTINATION<SOURCE-LEVEL)(G.PAHNTOM NAME:NUMBER) SAT999:0001 CAM999:CAM003<STU111 -1 CAM999:CAM004<STU111 -1 ...:...<...
Page 65
6. Decide Remote Control Units Can Be Active on the S-BUS (1) Available Stations (Menu Item [F]) Make secondary stations available by setting “E” on the menu item [F : SET ACTIVE UNIT NUMBER. The stations that are enabled will be polled by the primary, for panel activity, and status updates. ENABLE ACTIVE UNIT FOR STATION NUMBER 1 2 3 4 5 001-020...
Page 66
4-4. Basic Setup Procedures 7. Inhibit Crosspoint Table (Menu Item [M]) Set invalid crosspoint table for the specified crosspoints that will not be allowed to be selected by various outputs INHIBIT TABLE on the primary station. On the table “X” means valid crosspoint, and “_” means invalid crosspoint. SET INHIBIT TABLE DEST.
Page 67
Instead of one large routing switcher, there are often 2 separate routing switchers. One handling 4:2:2, and the other 4fsc. The output of the 4:2:2 would cascade through the 4:2:2 to 4fsc converters, and on to the inputs of the 4fsc routing switcher. The opposite configuration would be set up for going from 4fsc to 4:2:2.
Page 68
4-4. Basic Setup Procedures 9. Description Name (Menu Item [J]) In addition to Type + Number names, letter names (16 letters can be displayed on the BKS-R3281, most through only display 7) can be used. This is called a “Description name”. To set to Description names mode, select DESCRIP.NAME using the menu item [J : NAME STYLE].
Page 69
4-4. Basic Setup Procedures 10. Control Panel Setup (Menu Item [R]) Each individual control panel is contacted, and programmed by selecting [R] in the setup menu, and then by entering the S-BUS address of the desired panel. If the control panels are enabled in the menu item [Z : SET UNIT DETECTABLE], this might help you identify the panels address in question.
4-5. Flowchart of Setup 4-5. Flowchart of Setup Primary Station Setting DVS-V3232/FV6464B : Set S3 to "D" (Default) position on the CPU-149 board, then return S3 to "0" position. HDS-V3232 : Set S2 to "D" (Default) position on the CPU-251 board, then return S2 to "0"...
1. Set the switch S1-3 on BKPF-300/301/350/351 to “OFF (TERMINAL)” position. 2. Select the menu item [R: CALL SECONDARY STATION] from the menu screen of primary station, and call BKPF-300/301/350/351. The following screen appears. SONY ROUTING SYSTEM SETUP MENU SOURCE No: 0001 - 0008 SWITCHING FIELD: ASYNC Ctrl-D : RETURN Ctrl-E : RETURN TO MENU 1 SOURCE LOCATION of equipment.
5-1. Setting Items of the Primary Station A : DISPLAY CONTROL AREA A : DISPLAY UNIT LOCATION Purpose The menu items [A : DISPLAY CONTROL AREA] and [A : DISPLAY UNIT LOCATION] are used to check the source and destination area of the whole routing system to be controlled by the primary station.
5-1. Setting Items of the Primary Station B : SET SOURCE/DEST TYPE Purpose This menu is used to set the type name of the source destination and global phantom table. The menu makes the management of source/destination easier. Setting Procedure 1.
Page 75
1. The same destination name cannot be registered at more than two destinations. If this is done, an error message will be displayed at the bottom of the screen. Example: “VTR001 is used already; Ignored” destination name 2. When the Description name mode is selected at menu item [J], both Description name and “Type + number”...
5-1. Setting Items of the Primary Station D : SET SOURCE NAME Purpose This menu is used to set the source name and secret function (inhibition of source selection with a remote control unit). A number between 001 to 999 and a type name set at the menu item [B : SET SOURCE/DEST TYPE] can be set to each source name.
Page 77
Operating Function Keys [F1] : SEARCH (To move the cursor to the desired source name) 1. When [F1] is pressed, “Please Input SOURCE NAME =” will be displayed. 2. Input the source name to be retrieved. 3. When [Enter] is pressed, the cursor will move to the desired source name.
5-1. Setting Items of the Primary Station E : SET LEVEL TABLE Purpose This menu is used to assign the level name and the level to each destination name. Up to eight levels can be set. In this menu, set only the necessary levels. If levels which have not actually been used are set, the response of the routing switcher system will become slower.
F : SET ACTIVE UNIT NUMBER Purpose This menu is used to enable the units connected to the S- BUS data link to communicate. Setting Procedure 1. Select menu item [F]. 2. Press the cursor keys to select the secondary station whose communication will be valid.
5-1. Setting Items of the Primary Station H : SET GLOBAL PHANTOM The phantom function switches several crosspoints together with one button pushing of a remote control unit. The crosspoints of different levels can be also switched with this function. There are two kinds of phantoms such as local phantom and global phantom (refer to the menu item [H : SET PHANTOM TABLE] of secondary stations for local...
Page 81
3. As the cursor is placed where the name is typed, press [Enter]. The input mode will be set. 4. Select the codes assigned to each type name and enter any number using the cursor. Press [Enter] key to set it.
5-1. Setting Items of the Primary Station J : NAME STYLE Purpose This menu is used to switch the name styles of the destina- tion and source. The “Type + Number” name (Type + Num) or “Descrip- tion” name (DESCRIP. NAME) can be set. Names on the setting screen of menu items [C], [D], [E], [H], [L], [M], [N], [O], and [Q] are switched according to this menu.
K : RESET TO DEFAULT TABLE K : DEFAULT TABLE Purpose This menu is used to initialize the table data. Do not perform this menu when modifying the table data. Setting Procedure 1. Select menu item [K]. The message “RESET TO DEFAULT TABLE? (y/n)”...
Page 84
5-1. Setting Items of the Primary Station ..Destination Number Setting Procedure Press [F5] to set the destination number setting screen. Then, perform the same procedure as for source. PHYSICAL NUMBER ASSIGNMENT DVS-V6464B V2.10 STATION NUMBER 1 DESTINATION LEVEL No.
M: SET INHIBIT TABLE Purpose This menu is used to protect source numbers not to be selected for each destination. When the secret function is set to a source name, the selected source cannot be output to all destinations. By using this menu, source numbers to be inhibited can be assigned for each destination.
5-1. Setting Items of the Primary Station N : SET DESCRIPTION NAME GROUP Purpose To register the Description names required for each remote control unit, set the group of Description names. Up to eight such source and destination groups can be set. (Up to 160 names can be registered for one group.) The top half of the screen is for setting the group and the bottom half displays the list of Description names.
Page 87
..Transferring Data to the Secondary Station on the Monitor S-BUS To transfer the data on the group setting screen currently displayed to a secondary station on the monitor S-BUS, the number of the primary station on the monitor S-BUS must be specified, in addition to the secondary station number.
5-1. Setting Items of the Primary Station O: SET TIE LINES Purpose This menu is used to store the connection information of the matrix in the primary station and to set the tie line for switching several crosspoints using the remote control unit button. Using this method, peripheral units such as the signal converters can be used more efficiently.
Page 89
8. Select the number of net group with cursor keys and press [Enter] to set the input mode. Set the signal path between two routing switchers, using the combination of the “OUT of the front stage” > “IN of the latter stage”. 9.
5-1. Setting Items of the Primary Station P : CHANGE PASSWORD Purpose This menu is used to change the password. Setting Procedure 1. Select menu item [P]. 2. Input the password currently set, and press [Enter]. In the default status, password is not set in DVS- V3232B/V6464B.
Page 91
Operating Function Keys [F1] : SEARCH (To select a destination name) 1. When [F1] is pressed, “Please Input DEST NAME =” will be displayed. 2. Input the destination name to be retrieved. In the Description name mode, input the Description name (within seven characters) from the head.
S : SELECT INDICATION COLOR (Except for BKPF-R70 and HDS-V3232) Purpose If this menu is set to “ON”, the screen will show a color display during the use of the Sony control terminal BAC- 1200. Setting Procedure 1. Select menu item [S].
U : SELECT REMOTE Purpose This menu is used to control the routing switcher using the 9-pin remote (REMOTE 2), and to set the control mode to the DIRECT mode or the S-BUS conversion mode. Setting Procedure 1. Select menu item [U]. 2.
5-1. Setting Items of the Primary Station V : SELECT WARNING DISPLAY Purpose This menu is used to set the warning message displayed on the system status screen. Setting Procedure 1. Select menu item [V]. 2. Press [V], [Enter], and the setting conditions dis- played will be switched.(“ON”...
W:SYSTEM STATUS LOG Purpose This menu is used to check the error during self-diagnosis of each station, the status of the S-BUS circuit, and the time of events. SYSTEM STATUS LOG DVS-V6464B V2.10 STATION NUMBER 1 1990.10.12-15:42 S-BUS LINK DISCONNECTED 1990.10.27-09:28 STARTED BY BKS-R1601 Ver3.10 IN STATION 11 1990.11.03-05:31 STARTED BY BKS-R3204 Ver3.11 IN STATION 32 1991.01.14-13:51 MISSING REFERENCE SIGNAL IN STATION 1...
5-1. Setting Items of the Primary Station Y : DISPLAY TABLE (Except for HDS-V3232) Purpose This menu is used to display the table data set with the control terminal. Operation Procedure 1. Select menu item [Y]. The following message will be displayed at the bottom of the screen.
5-2. Setting Items of the Secondary Station A:SET UNIT LOCATION Purpose This menu is used to set the input/output location of the routing switcher. Setting Procedure 1. Select menu item [A]. 2. Use the cursor keys ([&], [*] to select the setting item.
5-2. Setting Items of the Secondary Station G:UPDATE BACKUP CONTROLLER Purpose This menu is used to copy the table data stored in the main CPU board of the secondary station to the backup CPU board. This setting is valid only when the optional CPU board is installed to the secondary station.
Description has priority to the display of “Type + Number” even if the “Type + Number” name is set. SONY ROUTING SYSTEM SETUP MENU BKS-R3204 V3.10 STATION NUMBER 16 SET PHANTOM TABLE (PHANTOM:DESTINATION<SOURCE-LEVEL) (G.PHANTOM NAME:NUMBER) IN001 :OUT001 <IN001 -0 IN002 :OUT001 <IN002 -0 IN003 :OUT001 <IN003 -0 IN004 :OUT001 <IN004 -0 IN005 :OUT001 <IN005 -0 IN006 :OUT001 <IN006 -0...
Page 100
5-2. Setting Items of the Secondary Station 5. When [Enter] is pressed, the phantom table will be set. 6. When [Ctrl] _ [E] is pressed, the menu screen of the secondary station will be displayed. When [Ctrl] _ [D] is pressed, the menu screen of the primary station will be displayed.
When [Ctrl] _ [D] is pressed, the screen will return to the menu screen of the primary station. SONY ROUTING SYSTEM SETUP MENU BKS-R3202 V3.10 STATION NUMBER 6 A:Copy All table...
6. Press [Ctrl] _ [E] to return to the menu screen of the secondary station. Press [Ctrl] _ [D] to return to the menu screen of the primary station. SONY ROUTING SYSTEM SETUP MENU BKS-R1601 V3.10 STATION NUMBER 11 SET PANEL TABLE( SOURCE ) 01 KEY=IN001 02 KEY=IN002...
When [Ctrl] _ [D] is pressed, the menu screen of the primary station will be displayed. ROUTING SWITCHER SYSTEM (E) 5-2. Setting Items of the Secondary Station SONY ROUTING SYSTEM SETUP MENU BKS-R3219 V1.00 SET PANEL TABLE(SOURCE) CONTROL DESTINATION = OUT001...
The actual setting procedure is as follows. Select a key from the source side which you want to use as the TAKE button. Press the [T] button. SONY ROUTING SYSTEM SETUP MENU BKS-R1607 V1.10 STATION NUMBER 12 SET PANEL TABLE(SOURCE)
4. Press [Ctrl] _ [E] to display the menu screen of the secondary station. Press [Ctrl] _ [D] to display the menu screen of the primary station. SONY ROUTING SYSTEM SETUP MENU BKS-R3202 V3.10 SELECT DESTINATION NAME 001=OUT001 002=OUT002 003=OUT003...
Page 106
When the ranges of input and output selections are limited as shown in the above table, the setting display and the virtual matrix are configured as shown below. SONY ROUTING SYSTEM SETUP MENU BKS-R3216 V1.00 STATION NUMBER 4 SELECT SOURCE NAME...
Page 107
Example of setting : SRC TOP-SRC END=DST TOP-DST END indicates the applicable range of the offset-type phantom on the screen of example setting. When the range from IN001 to IN008, and the range from OUT001 to OUT004 are to be set as the applicable range, enter as follows.
6. Pressing [Ctrl] _ [E] switches to the menu screen of the secondary station. Pressing [Ctrl] _ [D] returns to the menu screen of the primary station. 5-36 SONY ROUTING SYSTEM SETUP MENU SET ROUTE(ROUTE DESTINATION:DESTINATION<SOURCE-LEVEL) ROUTE | DEST OUT001 : OUT017 < IN005 ...
3. Press [Ctrl] _ [E] to display the menu screen of the secondary station. Press [Ctrl] _ [D] to display the menu screen of the primary station. SONY ROUTING SYSTEM SETUP MENU BKS-R3206 V3.10 STATION NUMBER 16 GROUP No. = 1 No. Terminal Name Description Name No.
5-2. Setting Items of the Secondary Station U : SELECT REMOTE PROTOCOL Purpose This menu is used to set channels A and B of REMOTE 2 (D-sub 9-pin) to loop-through. When the REMOTE 2 control mode is set to DIRECT, this menu is used to set the protocol and the conversion table of the input/output numbers.
V : DISPLAY UNIT STATUS (Except for HDS-V3232) Purpose This menu is used to display the status of the hardware such as boards, etc. For the input/output boards and matrix boards of DVS- V3232B, channel 1 to 32 will be displayed. And FAN 1 and 2 will be displayed for DVS-V3232B.
“_” from the left) and press [Enter]. The item is toggled on and off every time [Enter] is pressed. (When the number is displayed, the item is ON. When “_” is displayed, the item is OFF.) SONY ROUTING SYSTEM SETUP MENU BKS-R3220 V1.03Å SET DISPLAY MODES DISPLAY MODES...
Z : SELECT SDI FORMAT (Except for HDS-V3232) Purpose This menu is used to set the format of signals fed to the input/output board of DVS-V3232B and DVS-V6464B with the control terminal. This setting is available when the manual switch for the format on each input/output board is OFF.
32) can not be assigned as DESTINATION. If all is set as DESTINATION, the KEYs 1 to 8 are set to “KEYs 1 to 8=S” automatically. SONY ROUTING SYSTEM SETUP MENU BKS-R3204 V3.10 STATION NUMBER 14 13 14 15 16 SET PANEL STATUS...
SONY ROUTING SYSTEM SETUP MENU BKS-R3205 V3.10 STATION NUMBER 11 SET PANEL STATUS PANEL MODE = 1 1:STAND ALONE 2:MOTHER SET SOURCE OR DESTINATION ASSIGNMENT KEY 1- 8 = S KEY 9-16 = S KEY 17-24 = S KEY 25-32 = S...
Page 116
When [Enter] is pressed to confirm the input number, the cursor moves to the next setting item. When you do not want to change the default value, do not input any number, but press [Enter]. SONY ROUTING SYSTEM SETUP MENU BKS-R3220 V1.03 SET PANEL STATUS DISPLAY MODE...
Page 117
Checksum of the program area that is used for starting up the ROM. PGM CHECKSUM=630F Check of the area in which the actual programs are stored. ROM CHECKSUM=FF68 Checksum of the entire ROM. SONY ROUTING SYSTEM SETUP MENU BKS-R3210 V1.10 SET PANEL STATUS DISPLAY MODE 1:STATUS 2:PROMPT PROTECT MODE...
5-2. Setting Items of the Secondary Station Z : SELECT CONNECTION (DVS-RS1616 only) Purpose As for DVS-RS1616, this menu is used to set, “M” (controlling side) or “S” (controlled side) for each 9-pin connector from 1 to 32. If a controller is connected to a 9-pin connector, set to (S). If a controlled device is connected to a 9-pin connector, set to (M).
5-3. Setting Items of the Primary Station on Monitor S-BUS (BKDS-V3292B only) Used for setting the units on the monitor S-BUS. SET MONITOR FUNCTION DVS-V6464B Monitor Bus I/F V2.10 MODIFICATION COMMAND F: SET SCTIVE UNIT NUMBER M: SELECT MONITOR FUNCTION (COMBINED) R: CALL SECONDARY STATION Menu Screen of the Primary Station on Monitor S-BUS Setting Procedure of Monitor Function...
5-3. Setting Items of the Primary Station on Monitor S-BUS (BKDS-V3292B only) M: SELECT MONITOR FUNCTION Purpose This menu is for setting the connection to use the input monitor and output monitor in series or independently. To monitor the input and output monitor lines using separate monitors, set the SEPARATED mode.
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) M: SET AVAILABLE MONITOR LINE (DVS-V3232B/V6464B + + + + + BKDS-R3292B) SET MONITOR FUNCTION DVS-V6464B Monitor Bus I/F V2.10 STATION NUMBER 23 MODIFICATION COMMAND M: SET AVAILABLE MONITOR LINE INPUT=( ENABLE )OUTPUT=( ENABLE ) Ctrl-Z:RETURN Menu Screen of the Secondary Station on Monitor S-BUS (DVS-V3232B/V6464B)
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) N : SET PANEL TABLE (BKS-R1607/R1608/R3204/R3205/R3209/R3210) <MONITOR MENU> Purpose This menu is used to assign source/destination name to each source/destination selection button. In the monitor mode, the button color of the remote control unit will be green for both source and destination.
The actual setting procedure is as follows. Select a key from the source side which you want to use as the TAKE button. Press the [T] button. SONY ROUTING SYSTEM SETUP MENU BKS-R1607 V1.10 STATION NUMBER 12 SET PANEL TABLE(SOURCE)
5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only) In BKS-R1607/R1608/R3209/R3210 of version V1.10 and higher, the 160 description names that are transferred from the primary station can be registered in the range of inputs 512 x outputs 512 in the order of terminal number regard- less of the block number.
Page 125
Setting Procedure 1. Select menu item [Z]. 2. The cursor appears at “DISPLAY MODE=1.” Move the cursor to the desired mode. (Use the keys [(], [)].) Press [Enter] to enter the input mode. 3. Input the number to be selected using the numerical keys.
Data can be backed up easily by using the Sony routing switcher system control software BZR-1000 (run with a IBM PC/AT or compatible machine) or BZR-10.
5-7. Initialization of Table Data There are five ways of initializing the table data. Note that the way to be used depends on which item is initialized. 5-7-1. Initializing Procedure and Corresponding Items DVS-V3232B/V6464B : Initializing Procedure 1. Set the test switch (S3) on the CPU-149 board to “D”. 2.
5-7. Initialization of Table Data HDS-V3232 : Initializing Procedure 1. Set the test switch (S2) on the CPU-251 board to “D”. 2. Press the reset switch (S8). 1. Set the test switch (S2) on the CPU-251 board to “C”. 2. Press the reset switch (S8). Select the menu item [K : RESET TO DEFAULT TABLE] of the primary station and press [Y].
5-8. Signal Switching Timing For DVS-V3232B/V6464B and HDS-V3232, a SWITCHING FIELD which switch signals from the control terminal can be set. The SWITCHING FIELD are set using menu item “Z” of the secondary station and any SWITCHING FIELD mode (ODD, EVEN, FIELD, ASYNC) can be selected. The signal switching timing depends on whether it is controlled by RS-422A or the S-BUS.
Section 6 Confirmation of function 6-1. Outline After the hardware and software have been set up, it is necessary to check if the system is working properly before starting the operation. Each routing switcher is equipped with the self-diagnosis function to check the system connection and status of each unit.
6-2. Function Check Format 6-2. Function Check Format The contents of each function and the structure of the error displays are as follows. LED Display for Internal Information LED displays the presence/absence of the signals and setting of the switches independently, irrespective of the self- diagnosis and test mode.
6-3. How the Self-Diagnosis Items are Related Status Indicator Lit in Green: Operating Normally Blinking in Green: Faulty sync signal detection Faulty sync signal detection Blinking in Red: Faulty crosspoint Faulty crosspoint hardware hardware Increase in the switcher's Increase in the switcher's internal temperature/Fan has stopped internal temperature/Fan has stopped...
6-4. Diagnosis Items for Each Model 6-4. Diagnosis Items for Each Model Self-diagnosis Items Error Display * * * * * 1 Status Indicator Checking normal operations Detecting sync signals Detecting the sync signals of the timing generator Sync signal lock function of the timing generator OK/NG of crosspoint hardware...
6-5. Function Check Process After installing the hardware and software of the routing switcher system, check its functions and those of each device according to the following procedures. The process of the function check consists of three steps. The checks in step 2 and onward will be performed only when errors have been detected in step 1. If not, the checking process ends there.
If the result of the self-diagnosis is normal, “OK” will be displayed for this item. If errors have been detected, the corresponding item will be the reversal characters. SONY Digital Routing System DVS-V6464B V2.10 ROM CHECK SUM RAM READ AND WRITE...
6-6-2. System status screen during the system operation When a message is output to the S-BUS data link, the system status screen will display this message with the date and time of occurrence. When an error occurs during the operation of the system, the error message will be displayed.
6-6. Function Check with Control Terminal 6-6-4. Contents and countermeasures of the error messages The control terminal will display eleven types of error messages according to the error content. However, depending on the model, some are not used because of no detection, or some part of the message may differ.
Page 139
DIFFERENT CHECK SUM= ???? IN STATION * * * Content : This message is displayed when an error has been detected as the result of ROM checksum and RAM writing tests performed after resetting the unit. Countermeasure : Replace the corresponding ROM. This error message will be displayed even after the ROM has been replaced.
Page 140
6-6. Function Check with Control Terminal STATION * * * FAILURE(DISCONNECTED OR POWER DOWN) Content : This message is displayed when communication with the station set at the menu item [F] is stopped. Countermeasure : Check the status indicator of station * * *, and perform the adjustment corresponding to the symptom.
Section 7 Change Information on DVS-128/HDS-X3000 Series and DVS-V3232M/V6464M 7-1. Outline (DVS-128/HDS-X3000 Series) The S-BUS protocol is extended of its virtual matrix size from 512 to 1024. At the same time the following functions are changed. . Number of SOURCE/DEST TYPEs is extended from 16 to 32. .
The menu screen shown below is based on the DVS-128. Initial screen (DVS-128/HDS-X3000 Series) When the [Ctrl] _ [X] key is pressed after the main power is turned on, the following display appears. SONY ROUTING SYSTEM SETUP MENU MODIFICATION COMMAND A: DISPLAY CONTROL AREA...
A : DISPLAY CONTROL AREA (DVS-128/HDS-X3000 Series) Purpose This menu displays the control size as the primary station. DISPLAY CONTROL AREA DVS-128 V1.00 STATION NUMBER 1 SOURCE No 0001-1024 DESTINATION No 0001-1024 LEVEL 1-8 Example of Display Screen When LEVEL: 1 to 16 on the [E: SET LEVEL TABLE] screen is set to 1, the message [SOURCE No.
7-2. Changed Menu (Primary Station Setting Items) E : SET LEVEL TABLE (DVS-128/HDS-X3000 Series) Purpose The level name can be set, and the valid level for each output terminal can be set. Number of levels of either 8 or 16 can also be selected. LEVEL TABLE DVS-128 V1.00 1=VIT...
Page 145
(Example) An example in which the three matrices of 10 x 10 are used and are connected by the Tie-Line, is shown. A signal of IN 1-10 and IN 13-20 can be selected from OUT 21-30 in this example. SET TIE LINES DVS-128 V1.00 STATION NUMBER 1 --PATHS 1------------------------------------------------------------------ SOURCE: SOURCE No.
7-2. Changed Menu (Primary Station Setting Items) 7-3. Changed Menu (Secondary Station Setting Items) S : SET SOURCE ASSIGNMENT (DVS-128/HDS-X3000 Series) Purpose Change/addition/deletion of the MULTIPLE SOURCE name are performed here. When the signal name that has been set as level 1 from the remote control, is supposed to be named as TAKE, the signals whose source numbers are set here, can be selected in the level 2 and later.
Operating Function Keys [F1] : TABLE (Mode which assigns source and destina- tion to the buttons) This setting is valid for local input/output physical ter- minals of the HDS-X3400. The SOURCE and DESTI- NATION of other unit cannot be set from this button. [F2] : LED (Mode which adjusts brightness of the button.) 1.
7-3. Changed Menu (Secondary Station Setting Items) V : DISPLAY UNIT STATUS (HDS-X3000 Series) Purpose Purpose is to display the internal status of the equipment. There are no setting on this screen. Press [Ctrl] _ [E] to return to the menu screen of the secondary station.
FANA, FANB : ROT/STOP Displays whether the fan on the matrix board is rotating or not. FANn : ROT/STOP Displays whether the fan of the main unit (except the power supply unit) is rotating or not. FRONT PANEL : BKS-R3400/INVALID Displays whether the option switch is attached to the front of the HDS-X3400 or not.
Page 150
7-3. Changed Menu (Secondary Station Setting Items) SELECT SDI FORMAT HDS-X3600 V1.00 STATION NUMBER 1 DESTINATION UNIT SOURCE UNIT 01 - 08 : HD SDI(RC) 01 - 08 : 09 - 16 : HD SDI(RC) 09 - 16 : 17 - 24 : HD SDI(RC) 17 - 24 : 25 - 32 : HD SDI(RC) 25 - 32 :...
Z : SELECT SDI FORMAT (DVS-V3232M/DVS-V6464M) Purpose This menu is used to set the format of signals fed to the input/output board of DVS-V3232M and DVS-V6464M with the control terminal. This setting is available when the REM/LOC switch for the format on each input/output board is OFF.
Page 152
7-3. Changed Menu (Secondary Station Setting Items) “AUTO” stands for “AUTO LOCK” mode in which the input signal format (143/177/270/360/540 Mbps) is automatically identified and the equipment runs on an appropriate signal format. The signal format setting can be changed by pressing either [Enter] or [F]. [Enter] [Enter] [Enter]...
Page 153
Comparison Table between Models Item Dedicated CPU for communication SOFT MATRIX A : DISPLAY CONTROL AREA B : SET SOURCE/DEST TYPE C : SET DESTINATION NAME D : SET SOURCE NAME E : SET LEVEL TABLE F : SET ACTIVE UNIT NUMBER G : UPDATE BACKUP CONTROLLER H : SET GLOBAL PHANTOM J : NAME STYLE(Type+Num)
Functions and Menu Items Function Purpose Standard setting Initializing table data Set/change password Set time clock Select warning display ON/OFF Set type name Select input/output name style Set destination name Set source name Set description name group Set level table Set active unit number Copy main CPU data to backup CPU Set physical assignment...
Page 156
Function Purpose Monitor function Call secondary station Call primary station on monitor S-BUS M : SET MONITOR FUNCTION Set active unit number Select monitor mode Call secondary station on monitor S-BUS R : CALL SECONDARY STATION Set available monitor unit Set panel table Copy table data Display Description name...
Page 157
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.