Epson Stylus SX230 series / SX235W series / SX430W series / SX440W series
2.4 Routing FFCs/cables
Right side of Main Board
Main Board
CN6
CN102
Head FFC
PF Motor cable
CR Motor
PS Unit cable
cable
CN12
CSIC FFC
Card Slot Board cable
Connect the following cables/FFCs to the Main Board as shown in the figure above.
•
CSIC FFC (CN6)
•
Head FFC (CN102)
•
PF Motor cable (CN13)
•
PS Unit cable (CN501)
•
Wireless LAN Module cable (CN4: SX235W series/SX430W series only)
•
Panel FFC (CN2)
Attach the ferrite core A to the FFC Holder MB, and route the FFC through the ferrite core A and connect it to the Main Board.
•
Scanner FFC (CN11)
Attach the ferrite core B to the FFC Holder MB, and route the FFC through the hole of the Housing Left and the ferrite core B, and then connect it to the Main Board.
•
Card Slot Board cable (CN9:SX230 series/SX430W series only)
Panel Unit (1)
Hole for
grounding wire
Panel FFC
Panel Stand
Panel FFC
Frame Base
Grounding wire
(SX230 series / SX430W series only)
Route the Panel FFC and grounding wire (SX230 series / SX430W series
only) as follows before installing the Panel Unit.
•
Route the Panel FFC through the hole of the Frame Base as shown
above with the side with the stiffener upward.
•
Pull out the grounding wire from the hole of the Frame Base shown
above. (SX230 series / SX430W series only)
Before installing the Panel Unit, make sure that the Panel FFC is routed
correctly without any part getting caught.
Disassembly/Reassembly
Main Board
Left side of Main Board
FFC Holder MB
Ferrite core A
Ferrite core B
Panel FFC
PF Encoder FFC
FFC through Hole
Wireless LAN
of Housing Left.
Module cable
Housing Left
•
CR Motor cable (CN12)
•
PF Encoder FFC (CN7)
Panel Unit (2)
Hole for
Hole A
Panel FFC
Panel FFC
Frame Base
Grounding wire
(SX230 series / SX430W series only)
Panel FFC
Hole A
Grounding wire
Hole
C.B.S-TITE SCREW 3x6 F/ZN-3C (6 ± 1 kgf·cm)
After installing the Panel Unit, route the Panel FFC and grounding wire pulled
out from the hole of the Frame Base as follows.
Route Panel FFC through the ribs (x2) of the Frame Base and Main Frame
with folded along the fold line, and then secure it with double-sided tape
on the position shown in the figure above.
Route the grounding wire through the hole A of the Frame Base, and secure
it to the Main Frame with the screw.(SX230 series / SX430W series only)
CN11
SX230 series/SX430W series
CN2
CN13
CN4
Panel Housing Lower Assy
CN7
CN501
CN9
SX235W series
Route Scanner
Route the Panel FFC through the hole of the Panel Housing Lower Assy with its terminal side upward as shown in the figure above.
Fold the Panel FFC aligning it with its folded lines, and then connect the FFC to the connector (CN1) on the Panel Board firmly.
Secure the grounding wire to the Panel Board with the screw, and pull it out from the hole of the Panel Housing Lower Assy.
(SX230 series/SX430W series only)
Panel Unit
Panel Unit
Frame Base
Double-sided tape
Rib
Route the Panel FFC through the hole of the Panel Housing Lower Assy with its side with the stiffener upward as shown in the figure above.
Fold the Panel FFC aligning it with its folded lines and attach acetate tape as shown above, and then connect the FFC to the connector (CN1) on the Panel
Board firmly.
Secure the grounding wire to the Panel Board with the screw, and pull it out from the hole of the Panel Housing Lower Assy.
Routing FFCs/cables
Inside the Panel Unit (SX230 series/SX235W series/SX430W series)
Panel Board
Panel FFC
Grounding wire
Panel Board
Panel FFC
Panel Housing Lower Assy
Inside the Panel Unit (SX440W series only)
Panel FFC
Acetate tape
Panel Board Unit
Panel Housing Lower Assy
Grounding wire
Revision B
Hole of Panel Housing Lower Assy
Pull out grounding
wire from here.
Panel FFC
Grounding wire
(SX230 series/SX430W series only)
C.B.P-TITE SCREW 3x10 F/ZN-3C (6 ± 1 kgf·cm)
Hole of Panel Housing Lower Assy
Pull out grounding
wire from here.
Panel FFC
Grounding wire
C.B.S-TITE SCREW 3x6 F/ZN-3C (6 ± 1 kgf·cm)