CAME VER10 Installation Manual

CAME VER10 Installation Manual

Operators for garage door
Hide thumbs Also See for VER10:

Advertisement

OPERATORS
FOR GARAGE DOORS
FA00045-EN
INSTALLATION MANUAL
VER10 - VER12
EN
English

Advertisement

Table of Contents
loading

Summary of Contents for CAME VER10

  • Page 1 OPERATORS FOR GARAGE DOORS FA00045-EN INSTALLATION MANUAL VER10 - VER12 English...
  • Page 2: Read Carefully

    HIS PRODUCT SHOULD ONLY BE USED FOR THE ENTIRE INSTALLATION SITE TO PREVENT UNAUTHORIZED PURPOSE FOR WHICH IT WAS EXPLICITLY DESIGNED PERSONS FROM ENTERING THE AREA ESPECIALLY . CAME S. • B NY OTHER USE IS DANGEROUS MINORS AND CHILDREN E CAREFUL WHEN...
  • Page 3 • D COMMAND DEVICE AWAY FROM CHILDREN TO PREVENT PARTS O NOT ENTER THE OPERATOR S AREA OF • D THE OPERATOR FROM BEING ACCIDENTALLY ACTIVATED OPERATION WHEN IT IS MOVING O NOT COUNTER • T HIS APPARATUS IS NOT FOR PEOPLE INCLUDING THE OPERATOR S MOVEMENT AS THIS COULD RESULT...
  • Page 4: Intended Use

    Operator, complete with control board with encoder, for sectional and overhead garage-doors. Intended use The VER10 - VER12 are designed to power overhead garage doors in residential and apartment block settings.  Any installation and/or use other than that specified in this manual is forbidden.
  • Page 5 3020 ÷ 4020 Description of parts ① 1. Cover ⑪ 2. Gearmotor 3. Transformer 4. Control board 5. Transmission arm for the VER10* ⑤ 6. Transmission arm for the VER12* ⑩ 7. Door fastening brace ③ 8. Guide fastening brace ④...
  • Page 6 Traction guides 001V0679 Chain guide L = 3.02 m. Counter-balanced overhead doors up to 2.4 m in height - Counter-balanced overhead doors up to 2.25 m in height - Sectional doors* up to 2.20 m in height. 001V0682 Chain guide T = 3.52 m. - Counter-balanced overhead doors up to 2.75 m in height.
  • Page 7: Cable Types And Minimum Thicknesses

    Preliminary checks ⚠ Before beginning, do the following: • make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules. It should completely cut off the power supply according to category III surcharge conditions (that is, with minimum contact openings of 3 mm);...
  • Page 8: Sectional Door

    Applicative examples SECTIONAL DOOR Sectional door with single Sectional door with double slide-guides slide-guide COUNTERBALANCED OVERHEAD DOOR, SPRING-BALANCED OVERHEAD DOOR, FULLY RETRACTING AND PROTRUDING PARTIALLY RETRACTING AND PROTRUDING INSTALLATION ⚠  The following illustrations are just examples, in that the space available for fitting the operator and accessories varies depending on the overall dimensions.
  • Page 9 Positioning the traction guide Sectional doors: above the spring-pole brace assembly. If the distance between the spring-pole and the upper part of the door is between 300 and 600 mm, use the V122 transmission arm. V122 For protruding overhead garage-doors, kepp the guide at 20 from the highest opening point. ☞...
  • Page 10 Fit the braces to the guide and to the ceiling ❸. ⚠ If necessary, fi t additional support rods ❹. M6 x 14 Drill the ceiling where the braces will god and fi t them to the ceiling using suitable dowels and screws. Fitting the transmission arm to the door Position the transmission arm brace to the door's top rail, perpendicularly to the traction guide ...
  • Page 11 Turn the release lever clock-wise . Move the traction assembly towards the door  and fasten the transmission arm using the supplied bolt . UNI 5739 M6 x 20 Fitting the operator to the guide Fasten the operator to the traction guide using the supplied screws . ...
  • Page 12: Electrical Connections

    Fit the cable gland into the corresponding hole  and fi t the electrical cables .  The number of cables depends on the type of system and accessories fi tted. ELECTRICAL CONNECTIONS FUSE TABLE Motor (A) Accessories (A) 3.15 Control device (mA) Line fuses (A) LIGHTS...
  • Page 13: Power Supply

    Power supply 230 V AC 50/60 Hz Eyelet end-piece for grounding connection. Terminals for powering up accessories: - 24 V AC - grid powered (230 V); - 24 V DC when the emergency batteries are operating; Overall allowed power: 40 W Command and control devices If a device is connected, remove the bridge.
  • Page 14: Safety Devices

    Safety devices Reopening while closing function (NC contact). When the door is opening, opening the contact causes the door to invert its movement until it is completely open. 10 11 If a device is connected, remove the bridge Signaling devices Flashing light connecting (contact rated for: 24 V AC - 25 W max).
  • Page 15 Adjusting the trimmers Trimmer Description of functions Sensitivity during slow-downs Adjusts the amperometric sensitivity that controls the force exerted by the motor during slow- downs; if the exerted force is greater than the setting, the system inverts the direction of travel. Automatic Closing Time Sets the open door's waiting time.
  • Page 16: Encoder Operation

    Encoder operation Obstruction detection when OPENING The door recloses. Obstruction detection when CLOSING The door inverts its travel direction and reopens. After three consecutive inversions, the door stays open and excludes the automatic opening. To reclose the door, press a control button or use the transmitter. Fastening the opening mechanical stop Release the operator and completely open the door.
  • Page 17 Position the mechanical stop against the traction assembly and fasten it. Mechanical stop Traction assembly Manually close the door until it latches shut. Establishing the closing and opening limit switch points Set DIP-switch 1 to ON, the programming LED will fl ash . Press the OP/CL button until the door reaches the closing strike plate .
  • Page 18 Press the ENC/RADIO button ❹ to memorize the closing point. OP.SENS. OP / CL OPEN ENC/RADIO OP.SENS. OP / CL OPEN ENC/RADIO SLOW.SENS A.C.T. CL.SENS. SLOW.SENS A.C.T. CL.SENS. + E - + E - 26V 17V 0V 26V 17V 0V C.
  • Page 19 Programming the partial opening When the door is fully closed, set DIP-switch 2 to ON, the LED will fl ash . Press the OPEN button until the door reaches the wanted opening position . Press ENC/RADIO to memorize the partial opening . Reset DIP-switch 2 to OFF .
  • Page 20 Press the OP/CL button until the door reaches the desired end slow-down point  - Press the ENC/RADIO button until the LED stays on to signal that memorization is now complete . Reset DIP-switch 1 to OFF . Programming the closing slow-down (min. 600 mm from the final closing strike or max. 50% of the door travel) When the door is fully closed, press the ENC/RADIO button, the LED will fl...
  • Page 21 Press the OPEN button until the door reaches the desired closing slow-down start point . PPress the ENC/RADIO button until the LED stays on to signal that memorization is now complete . Reset DIP-switch 2 to OFF . ACTIVATING THE RADIO CONTROL ...
  • Page 22 Activating for the (2-7) sequential command Press the ENC/RADIO button on the control board. The warning LED flashes. Press the button on the transmitter you wish to memorize. The LED stays on to indicate that memorization has been successful . ENC/RADIO ENC/RADIO OP / CL...
  • Page 23: Final Operations

    Deleting all of the memorized transmitters Set DIP-switch 1 and DIP-switch 2 to ON, the warning LED will start fl ashing . Press the ENC/RADIO button for 5 seconds, the LED starts fl ashing quickly and stays on to signal that deletion is complete . Reset the DIP-switches to OFF .
  • Page 24 RELEASING THE OPERATOR ⚠  This procedure must be done with the mains power cut off . ⚠  Manually releasing the operator can cause the door to move unexpectedly, if the door has any mechanical issues or is unbalanced. RELEASING Turn the release lever clock-wise. LOCKING Manually close the door until it latches shut.
  • Page 25: Troubleshooting

    TROUBLESHOOTING ISSUES CHECKS AND FIXES • The operator neither opens nor closes • Check the power supply and line fuses • The (1-2) NC safety contact is open • The operator opens but does not close • The N.C. safety contact (2-C1) is open •...
  • Page 26: Periodic Maintenance

    MAINTENANCE Periodic maintenance ☞ Before doing any maintenance, cut off the mains power supply, to prevent any hazardous situations resulting from the door's unexpected movement. Periodic maintenance log kept by users (every six months) Date Notes Signature Extraordinary maintenance ⚠  The following table is for logging any extraordinary maintenance jobs, repairs and improvements performed by specialized contractors.
  • Page 27: Dismantling And Disposal

    ☞  CAME S.p.A. applies a certified Environmental Management System at its premises, which is compliant with the UNI EN ISO 14001 standard to ensure the environment is safeguarded. Please continue safeguarding the environment. At CAME we consider it one of the fundamentals of our operating and market strategies. Simply follow these brief disposal guidelines:...
  • Page 28 Came S.p.A. Came S.p.A. Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c 31030 Dosson di Casier Dosson di Casier 33079 Sesto al Reghena Sesto al Reghena Treviso Treviso - Italy Pordenone Pordenone - Italy (+39) 0422 4940 (+39) 0434 698111...