OPERATOR
FOR GARAGE DOORS
FA00047-EN
INSTALLATION AND OPERATION
V6000
EN
English

Advertisement

Table of Contents
loading

Summary of Contents for CAME v6000

  • Page 1 OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000 English...
  • Page 2 Any other use is dangerous. Constantly clean the photocells' glass covers using a slightly CAME S.p.A. is not liable for any damage caused by water-moistened cloth; do not use solvents or other chemical improper, wrongful and unreasonable use • Keep these warnings products that may ruin the devices •...
  • Page 3: Reference Regulations

    ABS casing with display for keypad programming and a LED courtesy light. Intended use The V6000 operator is designed to power overhead and sectional garage doors used in homes and apartment buildings. Any installation and/or use other than that specified in this manual is forbidden.
  • Page 4 Packing list 1. One operator 2. One installation manual 3. Two anchoring perforated-plates 4. One curved lever 5. Two support braces 6. Three U-shaped braces 7. One guide - fitting brace 8. One door - fitting brace 9. Eight self-drilling hexagonal head M6x15 screws 10.
  • Page 5: Optional Accessories

    001V06003 Chain guide T = 4.02 m. - Spring-balanced overhead doors up to 3.25 m in height. - Sectional* doors up to 3.20 m in height. 001V06005 Belt guide T = 3.02 m. Counter-balanced overhead doors up to 2.4 m in height - Counter-balanced overhead doors up to 2.25 m in height - Sectional* doors up to 2.20 m in height.
  • Page 6: Standard Installation

    • Check that the door is properly balanced; when stopped at any interim point, it should maintain its balance and position; • If the door is fitted with a pedestrian door, it is obligatory to add a safety switch, connected to the STOP INPUT, to prevent the operator from moving when the pedestrian door is open.
  • Page 7: Sectional Door

    Applicative examples SECTIONAL DOOR * double-guide sectional * single-guide sectional door door COUNTERBALANCED OVERHEAD DOOR, SPRING-BALANCED OVERHEAD DOOR, fully retracting and protruding partially retracting and protruding INSTALLATION The following illustrations are just examples, in that the space available for fitting the operator and accessories varies depending on the overall dimensions.
  • Page 8 Fitting the slide guide Fit the slide guide to the center of the door opening, using suitable screws. E Lift the guide and place it horizontally to measure the distance from the ceiling and then choose the type of fastening to use. Install the support braces and the U-shaped brace onto the guide.
  • Page 9 Fitting the operator to the guide Fit the adapter to the drive shaft. The operator can be fi tted onto the guide: either in standard position or at a right angle Self-drilling 6 x 15 screw U-shaped brace Micro Guide Drive shaft with adapter Self-drilling 6 x 15 screw Guide...
  • Page 10 Moving the micro switch Disconnect the cables of the micro switch and remove the latter. Remove the operator's cover and the cable brace. Pull out the electrical cable and fi t it through the hole. Refi t the cable brace so as to block the hole. Use a screwdriver to open up the predrilled hole for the electrical cables of the micro switch and for the cables to the micro switch.
  • Page 11: Electrical Connections

    Release the operator Latch ⓒ To release the operator, pull the cord ⓒ downwards. Locking To lock the operator back into place, use the transmitter or a command button. ELECTRICAL CONNECTIONS Before powering up the board, cut off the mains power supply. FUSE TABLE Power supply (V - 50/60 Hz): 230 AC Line fuses (A)
  • Page 12 Movement control and obstacle detection When OPENING: the door stops. To resume movement, either press a button or use the transmitter. When CLOSING: inverts the direction of travel until opening is complete. After three consecutive inversions, the door stays open and excludes the automatic closing: to close, either use the transmitter or button.
  • Page 13 Safety devices If a device is connected, remove the bridge Contact (NC) for reopening during closing. Input for safety devices such as photocells, sensitive safety- edges and other devices that are compliant with EN 12978 standards. During closing, opening this contact triggers an inversion of movement until the door is completely open.
  • Page 14 Some functions must be set so that the operator can work, others, on the other hand, are optional Obligatory functions Establishing the opening limit-switch points Respect the order of settings of the limit switches shown in this manual. With the operator idle Press P for about fi...
  • Page 15: Adjusting The Sensitivity

    Memorizing the programming It is OBLIGATORY to conclude the programming procedures with this function so as not to lose any saved settings! Press + to select 5. Press P. The display segments rotate clockwise. The programming is now memorized. Adjusting the sensitivity The door must be properly balanced.
  • Page 16: Optional Functions

    Optional functions Setting the alarm By default, this function is deactivated; by activating the alarm function, the operator emits a long sound signal if the door stays open for more than 10 minutes. To activate it: Press P for about fi ve Press + and select 1.
  • Page 17: Deleting Transmitters

    The operator emits a sound signal for 20 seconds before the door starts to automatically close. Simultaneou- sly, the courtesy light fl ashes. When the door starts closing, the operator emits a sound signal and the courtesy light comes on. When the door is closed, the operator does not emit any sound signal and the courtesy light stays on for three minutes.
  • Page 18: Maintenance

    MAINTENANCE ☞ Before any maintenance jobs, cut off the mains power, to prevent possible hazards from unwanted movements by the operator. Lubricate the rotation points using grease whenever squeaks or vibrations appear. Periodic maintenance Periodic maintenance log to be filled in by users every six months. Date Notes Signature...
  • Page 19: Extraordinary Maintenance

    Extraordinary maintenance The following table is for logging any extraordinary maintenance jobs, repairs and improvements performed by specialized contractors. Any extraordinary maintenance jobs must be done only by specialized technicians. Extraordinary maintenance log Fitter's stamp Name of operator Job performed on (date) Technician's signature Requester's signature Job performed _______________________________________________________...
  • Page 20: Dismantling And Disposal

    ☞ CAME S.p.A. applies a certified Environmental Management System at its premises, which is compliant with the UNI EN ISO 14001 standard to ensure the environment is safeguarded. Please continue safeguarding the environment. At CAME we consider it one of the fundamentals of our operating and market strategies. Simply follow these brief disposal guidelines:...