Steps for camera angle adjustment (For WV-SPW631LT and WV-SPW631LTJ only)
1. Slightly loosen the tilting lock screw (about 15°).
2. The camera angle is adjustable. If a fine adjustment is necessary, perform the following steps:
adjustment screw B
adjustment screw B
adjustment screw A
3. Tighten the tilting lock screw.
Note:
• A djustment is only possible in either downward or upward direction, depending on the factory settings.
• S ince the adjustable direction is fixed, you need to readjust the angle by starting over from Step 1 when a fine adjustment is not possible.
tilting lock screw
adjustment screw A
When the camera is mounted on a wall (a fine upward adjustment is pos-
sible):
Loosen adjustment screw B.
Tighten adjustment screw A, and then slightly tilt the camera upward.
After fine adjustment, tighten adjustment screw B.
Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}
When the camera is mounted on a ceiling (a fine downward adjustment is
tilting lock screw
possible):
Loosen adjustment screw B.
Tighten adjustment screw A, and then slightly tilt the camera downward.
After fine adjustment, tighten adjustment screw B.
Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}