Security and authentication
11.4 IP access control list
Parameter
src-port-number
dest-port-number
gt
lt
eq
range
any
host
dest-ip-address
dest-ip-address
dest-mask
dscp
value
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 42)".
Result
The IP access list for UDP datagrams has been configured.
Note
Subnet mask for individual hosts
If you create the rule for a single system (one IPv4 address), specify the subnet mask
"255.255.255.255". As an alternative, you can specify the keyword "host" followed by the
IPv4 address.
Further notes
You delete an IP access control list with the
command.
You display the configuration of the access control list with the
852
Description
Source port number
Destination port number
Keyword for port numbers higher than
the specified number (gt: greater than).
Keyword for port numbers lower than
the specified number (lt: less than).
Keyword for a specific port number
(eq:equal).
Keyword for a range of port numbers.
Following this, the first and last port
number of the range is specified.
Forwards all outgoing TCP segments.
Keyword for a an individual IPv4 ad-
dress
Destination IPv4 address
Network destination address
Corresponding subnet mask
Keyword for the Differentiated Services
Codepoint
Value for the Differentiated Services
Codepoint
no ip access-list standard <acl-num>
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
1 ... 65535
-
-
-
-
-
-
Enter a valid IPv4 address.
Enter a valid combination of IPv4
address and subnet mask.
-
0 ... 63
show access-lists
Configuration Manual, 06/2016, C79000-G8976-C252-11
command.