CHAPTER 7 PICK-UP/FEEDING SYSTEM
2. Removing the Paper Guide Plate
If the sheet attached to the paper guide
starts to deform (wavy) because of jams,
replace the paper guide. (If unattended, it can
cause more jams.)
1) Remove the delivery assembly.
2) Disconnect the connector [1].
3) Remove the four screws [2], and detach
the delivery reversal motor.
[1]
Figure 7-239
4) Remove the screw [5], and detach the
positioning screw [4].
[4]
Figure 7-240
5) Open the de-curling assembly.
6) Remove the spring [6], and detach the
paper guide plate [7].
7-64
[3]
[2]
[3]
[5]
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[6]
Figure 7-241