Sign In
Upload
Manuals
Brands
Panasonic Manuals
Touch terminals
GT707
Panasonic GT707 Manuals
Manuals and User Guides for Panasonic GT707. We have
3
Panasonic GT707 manuals available for free PDF download: Manual, User Manual
Panasonic GT707 Manual (136 pages)
Connection with other companies’ PLCs
Brand:
Panasonic
| Category:
Monitor
| Size: 8.73 MB
Table of Contents
Table of Contents
3
Applicable Plcs Manufactured by Various Companies
7
Selecting the PLC Model
12
1 Connection with Mitsubishi Plcs
13
MELSEC-FX1S/ FX1N/ FX1NC Series
14
Direct Connection to the TOOL Port
15
Using an Adapter
16
MELSEC-FX2N/ FX2NC/ FX3U/ FX3UC/ FX3G / FX3GC Series
17
Direct Connection to the TOOL Port
19
Using an Adapter
20
MELSEC-L (Serial Communication) Series
21
MELSEC-L (Serial Communication) Series
24
MELSEC-L (Serial Communication) Series (RS422)
24
MELSEC-L (CPU) Series
25
MELSEC-L (CPU) Series
28
MELSEC-Q (Serial Communication) Series
29
MELSEC-Q (Serial Communication) Series (RS232C)
32
MELSEC-Q (Serial Communication) Series (RS422)
32
When Directly Connecting to the RS232C Port of Q00CPU/ Q00UJCPU/ Q01CPU
33
MELSEC-Q (CPU) Series
34
MELSEC-A (Computer Link) Series
36
2 Connection with Omron Plcs
39
Omron SYSMAC-C Series (C/Α/CV/Cp1)
40
SYSMAC C Series (Using Link Interface) (RS232C)
43
SYSMAC Α Series (Using Link Interface) (RS232C)
46
SYSMAC CV Series (Using Link Interface) (RS232C)
47
SYSMAC CP1 Series (Using Link Interface) (RS232C)
48
SYSMAC CP1 Series (RS422/RS485)
49
SYSMAC CP1 Series (Built-In RS232C Port Type)
49
When Using the Peripheral Port of CPM2C
50
Omron SYSMAC-CS/CJ Series
52
SYSMAC CS1 Series (1:1) (RS232C)
56
SYSMAC CJ1 Series (1:1) (RS232C)
57
SYSMAC CS1/CJ1 Series (1:1) (RS422/RS485)
58
SYSMAC CJ2M Series (1:1) (RS232C)
59
SYSMAC CJ2M Series (RS422/RS485)
59
When Using the Peripheral Port
60
3 Connection with Toshiba Machine Plcs
63
PROVISOR Tcmini Series
64
RS232C Connection
65
RS485 Connection
66
4 Connection with Rockwell Automation (Allen-Bradley) Plcs
67
Allen-Bradley SLC500 Micrologix Series
68
SLC500 Series(Using Link Interface on the CPU Unit)
71
Micrologix1000/1100
72
5 Connection with Siemens Plcs
73
Siemens S7-200 Series
74
RS232C Connection (Connected with PC/PPI Cable)
75
RS422 Connection
76
6 Connection with LS Industrial Systems Plcs
77
MASTER-K (Cnet) Series
78
Connection Method
79
7 Connection with Yokogawa Plcs
81
FA-M3 Series
82
Connection Using PC Link Module
84
CPU Direct Connection
85
8 Connection with Keyence Plcs
87
KV-10/16/24/40 Series
88
Series
88
KV-700 Series
90
Connection Method
91
Series Connected Using Unit KV-L20R/V
92
Connection Method
93
KV-1000 Series
94
Connection Method
95
KV-1000 Series Connected Using Unit KV-L20R/V
96
Connection Method
98
KV-3000 Series
99
Connection Method
100
KV-3000/5000 Series Connected Using Unit KV-L20R/V
101
Connection Method
103
KV Nano Series
104
Connection Method
105
KV Nano Series Connected Using Unit KV-L20R/V
106
Connection Method
108
9 Connection with Hitachi Plcs
109
EH-150/EHV Series
110
RS232C Connection
113
RS422 Connection
117
RS485 Connection
118
MICRO-EH Series
119
RS232C Connection
121
Web Controller Series
123
RS232C Connection
125
RS422 Connection
127
RS485 Connection
128
10 Connection in Modbus (RTU Mode)
129
Modbus (RTU Mode | Modicon PLC)
130
Modbus (RTU Mode)
131
Modbus (RTU Mode) for Temperature Control Unit, Etc
132
Connection Method (Example)
134
Record of Changes
135
Advertisement
Panasonic GT707 Manual (67 pages)
GT Series Programmable Display
Brand:
Panasonic
| Category:
Touch terminals
| Size: 1.71 MB
Table of Contents
Safety Precautions
2
Table of Contents
3
1 Communication Methods
5
Communicating with External Devices
6
Communication between GT and External Devices
6
Communication Mode Type
7
Internal Memory Configuration
9
2 Settings and Connections
11
Setting on GTWIN
12
Selecting PLC Model
12
Selecting Communication Mode
13
Communication Parameters
14
Transmission of GT Configuration Data
15
Connecting to External Devices
16
3 Command Response Mode
17
What Is Command Response Mode
18
Overview of Communication Mode
18
Setting Communication Conditions
18
Basic Formats
19
Control Codes
20
Command Codes
20
BCC (Block Check Code)
21
Error Codes
22
Restrictions
22
Command Code Reference
23
4 Two-Way 1 Mode
29
What Is Two-Way 1 Mode
30
Overview of Communication Mode
30
Setting Communication Conditions
30
Change in CTS Signal When Responded from GT (Except GT01)
31
Basic Formats
32
Control Codes
33
Command Codes
33
BCC (Block Check Code)
34
Error Codes
35
Restrictions
35
Command Code Reference
36
Transmitting Commands from External Device
36
Transmitting Messages from GT
41
5 Two-Way 2 Mode
43
What Is Two-Way 2 Mode
44
Overview of Communication Mode
44
Setting Communication Conditions
45
Change in CTS Signal When Responded from GT (Except GT01)
46
Basic Formats
47
Control Codes
48
Command Codes
48
BCC (Block Check Code)
49
Error Codes
50
Restrictions
50
Command Code Reference
51
Transmitting Commands from External Device
51
Transmitting Messages from GT
57
6 Documentation
59
ASCII Code Table
60
Error Codes Table
61
Sheet for Basic Communication Area Allocation
62
Connection Diagrams
65
Precautions When Connecting GT
65
RS232C Connection
65
RS422 Connection
66
RS485 Connection (in Command Response Mode Only)
66
Panasonic GT707 User Manual (54 pages)
Programmable Display
Brand:
Panasonic
| Category:
Monitor
| Size: 0.88 MB
Table of Contents
Table of Contents
4
1 System Configuration
9
List of Models
10
GT Series Main Unit
10
Options
10
Screen Creating Tool
11
Tools Required for Screen Creation
11
Software Usage Environment and Applicable Cables
11
2 Names and Functions of Parts
13
Names and Functions of Parts
14
Gt707
14
Operation Mode Setting Switches
15
3 Installation and Wiring
17
Installation
18
Installation Environment
18
Restriction According to Mounting Directions
19
Installation Space
19
Mounting Screws
19
GT707 Installation Method
20
Installing in Vertical Orientation
21
Wiring the Power Supply
22
Precautions on Wiring
22
Wiring of Terminal Block
23
Grounding
24
Wiring of COM Port
25
Specifications of COM Port
25
Wiring Example of COM Port
26
Communication with PLC
28
Automatic Communication Settings Function
28
Through Function
29
Battery for Clock
30
How to Mount Battery for Clock
30
Lifetime and Time for Replacement of Battery for Clock
31
4 Troubleshooting
33
What to Do if an Error Occurs
34
Error Codes and How to Handle Them
39
About Error Codes
39
GT707 Series Error Codes
39
When Connected to a FP Series PLC
41
When Performing General-Purpose Serial Communication
42
5 Specifications
43
GT707 Specifications
44
General Specifications
44
Performance Specifications
45
Function Specifications
46
Interface Specifications
47
Dimensions
48
GT707 Main Unit
48
For Connecting PLC (AFC8503/AFC8503S)
49
Advertisement
Advertisement
Related Products
Panasonic GTWIN
Panasonic GT02
Panasonic GT03-E
Panasonic GT12
Panasonic GT32
Panasonic GT32-E
Panasonic GT703
Panasonic GT704
Panasonic GT704M
Panasonic GT703M
Panasonic Categories
Camcorder
Air Conditioner
TV
Digital Camera
Cordless Telephone
More Panasonic Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL