Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Inverter
FR-E540-0.75K-EC
Mitsubishi Electric FR-E540-0.75K-EC Manuals
Manuals and User Guides for Mitsubishi Electric FR-E540-0.75K-EC. We have
2
Mitsubishi Electric FR-E540-0.75K-EC manuals available for free PDF download: Instruction Manual
Mitsubishi Electric FR-E540-0.75K-EC Instruction Manual (208 pages)
TRANSISTORIZED INVERTER
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 3.04 MB
Table of Contents
Table of Contents
7
Pre-Operation Information
13
Precautions for Operation
13
Basic Configuration
15
Structure
16
Appearance and Structure
16
Removal and Reinstallation of the
17
Removal and Reinstallation of the Wiring Cover
18
Removal and Reinstallation of the Accessory Cover
19
Reinstallation and Removal of the Control Panel
20
Removal of the Operation Panel (FR-PA02-02)
22
Exploded View
22
Installation and Wiring
24
Installation
24
Instructions for Installation
24
Wiring
26
Terminal Connection Diagram (When Source Logic Is Selected)
26
Wiring of the Main Circuit
30
Wiring of the Control Circuit
35
Connection to the PU Connector
39
Connection of Stand-Alone Option Units
42
Design Information
44
Other Wiring
45
Power Supply Harmonics
45
Inverter-Generated Noise and Reduction Techniques
46
Leakage Currents and Countermeasures
50
Inverter-Driven 400V Class Motor
51
Peripheral Devices
52
Instructions for Compliance with U.S. and Canadian Electrical Codes
56
Instructions for Compliance with the European Standards
57
Operation/Control
60
Pre-Operation Information
61
Types of Operation Modes
61
Power on
63
About the Control Panel
64
Names and Functions of the Control Panel (FR-PA02-02)
64
Control Panel Mode Is Changed by Pressing the
65
MODE Key
65
Monitoring
65
Frequency Setting
65
Parameter Setting Method
66
Operation Mode
68
Help Mode
68
Operation
70
Pre-Operation Checks
70
External Operation Mode (Operation Using the External Frequency Setting Potentiometer and External Start Signal)
71
PU Operation Mode (Operation Using the Control Panel)
72
Combined Operation Mode 1 (Operation Using both External Start Signal and Control Panel)
73
Combined Operation Mode 2
74
Parameters
76
Parameter List
76
List of Parameters Classified by Purpose of Use
82
Parameters Recommended to be Set by the User
84
Parameter Function Details
85
Torque Boost (Pr. 0, Pr. 46)
85
Output Frequency Range (Pr. 1, Pr. 2, Pr. 18)
86
Base Frequency, Base Frequency Voltage (Pr. 3, Pr. 19, Pr. 47)
87
Multi-Speed Operation
88
(Pr. 4, Pr. 5, Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
88
Acceleration/Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45)
89
Electronic Overcurrent Protection (Pr. 9, Pr. 48)
91
DC Injection Brake (Pr. 10 to Pr. 12)
92
Starting Frequency (Pr. 13)
93
Load Pattern Selection (Pr. 14)
94
Jog Operation (Pr. 15, Pr. 16)
95
Stall Prevention (Pr. 22, Pr. 23, Pr. 66)
96
Acceleration/Deceleration Pattern (Pr. 29)
98
Regenerative Brake Duty (Pr. 30, Pr. 70)
99
Frequency Jump (Pr. 31 to Pr. 36)
100
Speed Display (Pr. 37)
101
Frequency at 5V (10V) Input (Pr. 38)
102
Frequency at 20Ma Input (Pr. 39)
102
Up-To-Frequency Sensitivity (Pr. 41)
103
Output Frequency Detection (Pr. 42, Pr. 43)
104
Monitor Display (Pr. 52, Pr. 158)
105
Monitoring Reference (Pr. 55, Pr. 56)
107
Automatic Restart after Instantaneous Power Failure (Pr. 57, Pr. 58)
108
Remote Setting Function Selection (Pr. 59)
109
Shortest Acceleration/Deceleration Mode (Pr. 60 to Pr. 63)
110
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
112
Applied Motor (Pr. 71)
114
PWM Carrier Frequency (Pr. 72, Pr. 240)
115
Voltage Input (Pr. 73)
116
Input Filter Time Constant (Pr. 74)
117
Reset Selection/Disconnected PU Detection/Pu Stop Selection (Pr. 75)
117
Parameter Write Inhibit Selection (Pr. 77)
119
Reverse Rotation Prevention Selection (Pr. 78)
120
Operation Mode Selection (Pr. 79)
121
General-Purpose Magnetic Flux Vector Control Selection (Pr. 80)
125
Offline Auto Tuning Function (Pr. 82 to Pr. 84, Pr. 90, Pr. 96)
126
Computer Link Operation (Pr. 117 to Pr. 124)
132
PID Control (Pr. 128 to Pr. 134)
143
Output Current Detection Function (Pr. 150, Pr. 151)
151
Zero Current Detection (Pr. 152, Pr. 153)
152
Stall Prevention Function and Current Limit Function (Pr. 156)
153
User Group Selection (Pr. 160, Pr. 173 to Pr. 176)
155
Actual Operation Hour Meter Clear (Pr. 171)
157
Input Terminal Function Selection (Pr. 180 to Pr. 183)
157
Output Terminal Function Selection (Pr. 190 to Pr. 192)
159
Cooling Fan Operation Selection (Pr. 244)
160
Slip Compensation (Pr. 245 to Pr. 247)
161
Stop Selection (Pr. 250)
162
Meter (Frequency Meter) Calibration (Pr. 901)
164
Biases and Gains of the Frequency Setting Voltage (Current)
166
(Pr. 902 to Pr. 905)
166
Protective Functions
173
Errors (Alarms)
173
Error (Alarm) Definitions
173
To Know the Operating Status at the Occurrence of Alarm
181
Correspondence between Digital and Actual Characters
181
Resetting the Inverter
181
Troubleshooting
182
Motor Remains Stopped
182
Motor Rotates in Opposite Direction
182
Speed Greatly Differs from the Setting
183
Acceleration/Deceleration Is Not Smooth
183
Motor Current Is Large
183
Speed Does Not Increase
183
Speed Varies During Operation
183
Operation Mode Is Not Changed Properly
184
Control Panel Display Is Not Operating
184
POWER Lamp Is Not Lit
184
Parameter Write Cannot be Performed
184
Precautions for Maintenance and Inspection
185
Check Items
185
Periodic Inspection
185
Insulation Resistance Test Using Megger
186
Pressure Test
186
Daily and Periodic Inspection
187
Replacement of Parts
190
Measurement of Main Circuit Voltages, Currents and Powers
194
Specifications
196
Standard Specifications
197
Model Specifications
197
Common Specifications
199
Outline Drawings
201
Appendix
203
Appendix 1 Data Code List
204
Advertisement
Mitsubishi Electric FR-E540-0.75K-EC Instruction Manual (202 pages)
Large Capacity Inverter
Brand:
Mitsubishi Electric
| Category:
Inverter
| Size: 4.14 MB
Table of Contents
Table of Contents
2
Outline
7
Pre-Operation Information
8
Precautions for Operation
8
Basic Configuration
10
Structure
11
Appearance and Structure
11
Removal and Reinstallation of the
12
Removal and Reinstallation of the Wiring Cover
13
Removal and Reinstallation of the Accessory Cover
14
Reinstallation and Removal of the Control Panel
15
Removal of the Operation Panel (FR-PA02- )
17
Front Cover
17
Exploded View
17
Installation and Wiring
19
Installation
19
Instructions for Installation
19
Wiring
21
Terminal Connection Diagram (When Source Logic Is Selected)
21
Wiring of the Main Circuit
25
Wiring of the Control Circuit
30
Connection to the PU Connector
34
Connection of Stand-Alone Option Units
37
Design Information
39
Other Wiring
40
Power Supply Harmonics
40
Japanese Harmonic Suppression Guideline
41
Inverter-Generated Noise and Reduction Techniques
41
Leakage Currents and Countermeasures
45
Inverter-Driven 400V Class Motor
46
Peripheral Devices
47
Instructions for Compliance with the UL and CSA Standards
50
Instructions for Compliance with the European Standards
51
Operaton
55
Pre-Operation Information
55
Types of Operation Modes
55
Power on
57
About the Control Panel
58
Names and Functions of the Control Panel (FR-PA02- )
58
Control Panel Mode Is Changed by Pressing the
59
MODE Key
59
Monitoring Mode
59
Frequency Setting Mode
60
Parameter Setting Mode
60
Operation Mode
62
Help Mode
62
Operation
64
Pre-Operation Checks
64
External Operation Mode (Operation Using the External Frequency Setting Potentiometer and External Start Signal)
65
PU Operation Mode (Operation Using the Control Panel)
66
Combined Operation Mode 1 (Operation Using both External Signal and Control Panel)
67
Combined Operation Mode 2
67
Parameters
70
Parameter List
70
List of Parameters Classified by Purpose of Use
76
Parameters Recommended to be Set by the User
78
Parameter Function Details
79
Torque Boost (Pr. 0, Pr. 46)
79
Output Frequency Range (Pr. 1, Pr. 2, Pr. 18)
80
Base Frequency, Base Frequency Voltage (Pr. 3, Pr. 19, Pr. 47)
81
Multi-Speed Operation
82
(Pr. 4, Pr. 5, Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
82
Acceleration/Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45)
83
Electronic Overcurrent Protection (Pr. 9, Pr. 48)
85
DC Dynamic Brake (Pr. 10 to Pr. 12)
86
Starting Frequency (Pr. 13)
87
Load Pattern Selection (Pr. 14)
88
Jog Operation (Pr. 15, Pr. 16)
89
Stall Prevention (Pr. 22, Pr. 23, Pr. 66)
90
Acceleration/Deceleration Pattern (Pr. 29)
92
Regenerative Brake Duty (Pr. 30, Pr. 70)
93
Frequency Jump (Pr. 31 to Pr. 36)
94
Speed Display (Pr. 37)
95
Frequency at 5V (10V) Input (Pr. 38)
96
Frequency at 20Ma Input (Pr. 39)
96
Up-To-Frequency Sensitivity (Pr. 41)
97
Output Frequency Detection (Pr. 42, Pr. 43)
98
Monitor Display (Pr. 52, Pr. 158)
99
Monitoring Reference (Pr. 55, Pr. 56)
101
Automatic Restart after Instantaneous Power Failure (Pr. 57, Pr. 58)
102
Remote Setting Function Selection (Pr. 59)
103
Shortest Acceleration/Deceleration Mode (Pr. 60 to Pr. 63)
104
Retry Function (Pr. 65, Pr. 67 to Pr. 69)
106
Applied Motor (Pr. 71)
108
PWM Carrier Frequency (Pr. 72, Pr. 240)
109
Voltage Input (Pr. 73)
110
Input Filter Time Constant (Pr. 74)
111
Reset Selection/Pu Disconnection Detection/Pu Stop Selection (Pr. 75)
111
Parameter Write Inhibit Selection (Pr. 77)
113
Reverse Rotation Prevention Selection (Pr. 78)
114
Operation Mode Selection (Pr. 79)
115
General-Purpose Magnetic Flux Vector Control Selection (Pr. 80)
119
Offline Auto Tuning Function (Pr. 82 to Pr. 84, Pr. 90, Pr. 96)
120
Computer Link Operation (Pr. 117 to Pr. 124)
126
PID Control (Pr. 128 to Pr. 134)
137
Output Current Detection Function (Pr. 150, Pr. 151)
145
Zero Current Detection (Pr. 152, Pr. 153)
146
Stall Prevention Function and Current Limit Function (Pr. 156)
147
User Group Selection (Pr. 160, Pr. 173 to Pr. 176)
150
Actual Operation Hour Meter Clear (Pr. 171)
152
Input Terminal Function Selection (Pr. 180 to Pr. 183)
152
Output Terminal Function Selection (Pr. 190 to Pr. 192)
154
Cooling Fan Operation Selection (Pr. 244)
155
Slip Compensation (Pr. 245 to Pr. 247)
156
Stop Selection (Pr. 250)
157
Meter (Frequency Meter) Calibration (Pr. 901)
159
Biases and Gains of the Frequency Setting Voltage (Current)
161
(Pr. 902 to Pr. 905)
161
Protective Functions
168
Errors (Alarms)
168
Error (Alarm) Definitions
168
To Know the Operating Status at the Occurrence of Alarm
176
Correspondence between Digital and Actual Characters
176
Resetting the Inverter
176
Troubleshooting
177
Motor Remains Stopped
177
Motor Rotates in Opposite Direction
177
Speed Greatly Differs from the Setting
178
Acceleration/Deceleration Is Not Smooth
178
Motor Current Is Large
178
Speed Does Not Increase
178
Speed Varies During Operation
178
Operation Mode Is Not Changed Properly
179
Control Panel Display Is Not Operating
179
POWER Lamp Is Not Lit
179
Parameter Write Cannot be Performed
179
Precautions for Maintenance and Inspection
180
Check Items
180
Periodic Inspection
180
Insulation Resistance Test Using Megger
181
Pressure Test
181
Replacement of Parts
185
Measurement of Main Circuit Voltages, Currents and Powers
189
Specifications
191
Standard Specifications
192
Model Specifications
192
Common Specifications
194
Outline Drawings
196
Appendix
198
Appendix 1 Data Code List
199
Advertisement
Related Products
Mitsubishi Electric FR-E540-0.4K
Mitsubishi Electric FR-E540-0.75K
Mitsubishi Electric FR-E540-0.4K-EC
Mitsubishi Electric FR-E540
Mitsubishi Electric FR-E540-3.7K
Mitsubishi Electric FR-E540-5.5K
Mitsubishi Electric FR-E540-7.5K
Mitsubishi Electric FR-E540-1.5K-EC
Mitsubishi Electric FR-E540-2.2K-EC
Mitsubishi Electric FR-E540-5.5K-EC
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL