hit counter script

Troubleshooting Using The 7 Segment Display (Outdoor Unit) - Hitachi RAS-H(V)RNME-AF Service Manual

Yutaki s series
Hide thumbs Also See for RAS-H(V)RNME-AF:
Table of Contents

Advertisement

12 Troubleshooting

12.1.4 Troubleshooting using the 7 segment display (outdoor unit)


Simple checking by 7-segment display
Turn ON indoor unit connected to
1
the outdoor unit
2
Turn ON the outdoor unit
3
Auto-addressing starts
Outdoor unit, circuit board, PCB1

Checking method by 7-segment display
Operating conditions and each part of refrigeration cycle can be checked by 7-segment and push switches (PSW) on the 
PCB in the outdoor unit. During checking data, do not touch the electric parts except for the indicated switches because 
220-240V is applied to them. Pay attention not to contact the tools with electrical parts. If contacted, electrical parts will be
damaged.
Y52C
8
8
Y20B
Y20A
FAN2
Manual
8
8
defrost
.
.
SEG1
PSW1 PSW2 PSW3
399
SMGB0070 rev. 1 - 08/2011
During  auto-addressing,  the  following  items  can  be  checked  using 
the outdoor unit's on-board 7-segment LED display:
1 Disconnection of power supply to the indoor unit.
2 Reverse connection of the operating line between the outdoor
and indoor units.
3 Duplication of indoor unit number.
•  To start checking, press PSW2 switch for more than three seconds.
Y21
•  To proceed checking, press the PSW2 switch.
•  To back to the previous item, press the PSW3 switch.
FAN1
•  To  cancel  this  checking,  press  the  PSW2  switch  for  more  than  3 
seconds.
YCH
PSH
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF