2. Emergency Memory Address
Page F
Address
10
1st EMG code
Upper: MSW code when the mechanism starts shifting
12
the 1st time
Lower: MSW code when the 1st emergency occurs
13
Lower: Target MSW code of the 1st emergency occurs
14
2nd EMG code
Upper: MSW code when the mechanism starts shifting
16
the 2nd time
Lower: MSW code when the 2nd emergency occurs
17
Lower: Target MSW code of the 2nd emergency occurs
18
Last EMG code
Upper: MSW code when the mechanism starts shifting
1A
the last time
Lower: MSW code when the last emergency occurs
1B
Lower: Target MSW code of the last emergency occurs
When there are no emergency, data 00 will be written in the above
addresses (10 to 1B). When the first emergency occurs, the data
corresponding to the emergency will be written in the address (10
to 13) for this first emergency. In the same way, when the second
emergency occurs, the data corresponding to the emergency will be
written in the address (14 to 17) for this second emergency.
The data corresponding to the emergency occurring the last will be
written in the address (18 to 1B) for this last emergency.
Therefore the data of addresses 18 to 1B are renewed each time an
emergency occurs.
Note 1: Be sure to rewrite the data of addresses 10 to 1B to 00
after repairs/adjustments.
Note 2: When rewriting the data, be sure to press the PAUSE
buttton of the remote commander after setting the data.
Address 10 to 1B
Contents
2-1. EMG CODE (Emergency Code)
The codes shown in the following table which correspond to errors
that occur are recorded in addresses 10, 14, and 18.
Code
00
No error
10
Loading motor time-out during load
Loading motor time-out during unload
11
20
T reel emergency (reel slack) during unloading
21
S reel emergency (reel slack) during unloading
T reel emergency
22
23
S reel emergency
FG emergency at the start up of the capstan
30
FG emergency during the normal rotation of the capstan
31
40
FG emergency at the start up of the drum
PG emergency at the start up of the drum
41
42
FG emergency during the normal rotation of the drum
PG emergency during the normal rotation of the drum
43
Phase emergency during the normal rotation of the
44
drum
5-31
Type of Emergency