8-2-6 LCD MONITOR
Items/
Adjustable
Data Saved
Range
BRIGHTNESS –7
Adjust the LCD monitor brightness.
:
+0
:
– C U F –
+7
COLOR LEVEL –7
Adjust the LCD monitor chroma level.
:
+0
:
– C U F –
+7
CONTRAST
–7
Adjust the LCD monitor contrast.
:
+0
:
– C U F –
+7
BACKLIGHT
HIGH
Select whether or not to set the LCD monitor
NORMAL
brightness to always high.
HIGH:
NORMAL: The brightness changes
– C U F –
SELF SHOOT
NORMAL
Select whether or not to change the LCD
monitor to mirror image.
MIRROR
NORMAL: Do not change to mirror image.
MIRROR:
– C U F –
ASPECT CONV. LT.BOX
Select a screen ratio for images displayed
on the LCD monitor.
SQUEEZE
LT.BOX: Display images in the letter box
SQEEZE: Display images in the squeeze size.
<Note>
This item is enabled only when ASPECT
described in [8-2-1 SYSTEM MODE] is set
– C U F –
to16:9.
Remarks
Set to always high.
according to the BRIGHTNESS
setting.
Change to mirror image.
size.
8-2-7 GENLOCK
Items/
Adjustabl
Data Saved
e Range
GENLOCK
INT
Switch the camera synchronising signal.
EXT
INT: Synchronise with the internal reference
signal regardless of the reference
26P EXT
signal input to the GENLOCK IN
terminal.
EXT: Synchronise with the reference signal
input to the GENLOCK IN terminal.
26P EXT:
Synchronizes to the signal input via the
26-pin connector.
– C U F E
H PHASE
–50
Perform coarse phase adjustment for
horizontal hold when configuring a system.
COARSE
:
+00
:
– – – – –
+50
H PHASE FINE –160
Perform fine phase adjustment for horizontal
hold when configuring a system.
:
+000
<Note>
:
This adjustment simultaneously shifts the SC
+160
phase.
– – – – –
SC PHASE
0
Perform coarse SC PHASE adjustment when
GENLOCK is set.
COARSE
1
:
3
– – – – –
SC PHASE
–75
Perform fine SC PHASE adjustment when
FINE
:
GENLOCK is set.
+00
<Note>
:
When adjusting GENLOCK, please adjust H
+75
PHASE first, and then adjust SC PHASE.
– – – – –
The ____ in the Adjustable Range column indicates the preset
mode.
Remarks
103
8