NN-GD371S / NN-GD361M / NN-GD351W 4 DESCRIPTION OF OPERATING SEQUENCE 4.1. Variable power cooking 4.3. Inverter defrost, Auto menu & control Auto reheat High Voltage Inverter Power Supply (U) controls output power When the Auto Control feature is selected and the Start button by the signal from Digital Programmer Circuit (DPC).
NN-GD371S / NN-GD361M / NN-GD351W 5 CAUTIONS TO BE OBSERVED WHEN TROUBLESHOOTING Unlike many other appliances, the microwave oven is a high voltage, high current device. It is free from danger in ordinary use, though extreme care should be taken during repair.
NN-GD371S / NN-GD361M / NN-GD351W 5.3. Part replacement. 5.7. Sharp edges When troubleshooting any part or component is to be replaced, CAUTION always ensure that the power cord is unplugged from the wall Please use caution when disassembling or reassembling outlet.
NN-GD371S / NN-GD361M / NN-GD351W 6 DISASSEMBLY AND PARTS REPLACEMENT PROCEDURE 6.1. Magnetron 6. Remove 2 screws holding the magnetron. 1. Discharge the high voltage capacitor. 2. Remove 1 screw holding front plate bracket on cavity top plate. 3. Remove 2 screws holding air guide A on cavity top plate and on magnetron.
NN-GD371S / NN-GD361M / NN-GD351W 6.4. DC fan motor 2. Disconnect 1 grounding connector from cavity front plate. 1. Disconnect DC fan motor connect CN15 from DPC board 2. Remove 2 screws holding orifice assy and detach the orifice assy from oven assy.
NN-GD371S / NN-GD361M / NN-GD351W 3. Remove door C from door A (U) & door E by carefully 6.5. Door assembly pulling outward starting from upper right hand corner using a flat blade screwdriver. 1. Support the door, remove 2 screws holding hinge A.
NN-GD371S / NN-GD361M / NN-GD351W 6.6. Turntable motor 9. Tighten 2 mounting screws. 1. Remove the motor cover by breaking off at the 4 spots indicated by arrows with a cutter or the like. NOTE: After removing the motor cover, be sure that cut...
NN-GD371S / NN-GD361M / NN-GD351W 6.8. H.V. Inverter Power Supply 6.7. Quartz heater 1. Disconnect 2 high voltage lead wires from magnetron 1. Disconnect lead wires from both side of heater terminals. filament terminals. 2. Bend back 2 locking tabs from left and right side of upper 2.
Page 15
NN-GD371S / NN-GD361M / NN-GD351W 6. Remove 2 screws holding H.V. inverter on the inverter bracket.
NN-GD371S / NN-GD361M / NN-GD351W 7 COMPONENT TEST PROCEDURE 7.3. Magnetron WARNING 1. High voltage is present at the output terminals of the High Voltage Inverter (U) including aluminum heat sink during any cook cycle. Continuity checks can only indicate an open filament or a 2.
NN-GD371S / NN-GD361M / NN-GD351W 7.5. Inverter power supply (U) d. Press Micro Power button once. DO NOT try to REPAIR H.V. Inverter power supply 5. Program oven at High power for 1 minute and press [Start] (U).Replace complete H.V. Inverter(U) Unit.
NN-GD371S / NN-GD361M / NN-GD351W 8 MEASUREMENTS AND ADJUSTMENTS 8.1. Adjustment of Primary latch 8.2. Measurement of microwave switch, Secondary latch output switch and Short switch. The output power of the magnetron can be determined by performing IEC standard test procedures. However, due to the 1.
NN-GD371S / NN-GD361M / NN-GD351W 9 TROUBLESHOOTING GUIDE DANGER: HIGH VOLTAGES 1. DO NOT RE-ADJUST PRESET CONTROL on the H.V.Inverter (U). It is very dangerous to repair or adjust without proper test equipment because this circuit generates very large current and high voltage. Operating a misaligned inverter circuit is dangerous.
Page 20
NN-GD371S / NN-GD361M / NN-GD351W SYMPTOM CAUSE CORRECTIONS 1. Oven is dead. 1. Open or loose lead wire harness Fuse is OK. 2. Open thermal cutout / thermistor Check thermal cutout is defective. No display and no operation at all.
NN-GD371S / NN-GD361M / NN-GD351W 9.2. Troubleshooting of inverter circuit (U) and magnetron This oven is programmed with a self diagnostics failure code system which will help for troubleshooting. H95, H97, H98 and H99 are the provided failure codes to indicate magnetron and inverter circuit problem areas. This section explains failure codes of H95, H97, H98 and H99.
NN-GD371S / NN-GD361M / NN-GD351W 9.3. Simple way of H.V. Inverter/magnetron troubleshooting Purpose: Simple way (3/23 seconds rule) of identifying whether it’s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below. Procedure: Follow the matrix table below to identify the problem source.
NN-GD371S / NN-GD361M / NN-GD351W 9.5. H.V. INVERTER MAIN PARTS LIST (Z606YBA00GP) Ref. No. Part No. Part Name & Description Pcs/Set Remarks Q701 Z1JAEV000003 IGBT C701 ZCWHC3B104JA FILM CAPACITOR 0.1µF,1000VDC C702 ZCWF4305N851 FILM CAPACITOR 3µF,250VDC DB701 Z0FBBQ000006 RECTIFIER BRIDGE L701...
NN-GD371S / NN-GD361M / NN-GD351W 10.2. PARTS LIST NOTE: 1. When ordering replacement part(s), please use part number(s) shown in this part list. Do not use description of the part. 2. Important safety notice: Components identified by mark have special characteristics important for safety.
NN-GD371S / NN-GD361M / NN-GD351W 10.4. DOOR ASSEMBLY Ref. No. Part No. Part Name & Description Pcs/Set Remarks Z30189V00XP DOOR KEY A Z302KBA00EP DOOR E (U) Z30215G10XN DOOR KEY SPRING Z30859V00XP DOOR C Z3145BB10EP DOOR SCREEN A Z302ABB10SEP DOOR A (U)