TUNER SECTION
0dB=1µV
AM Section
Procedure :
BAND
: AM
VOLUME
: MIN
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
FM Section
Procedure :
BAND
: FM
VOLUME
: MIN
FM RF signal
generator
22.5kHz frequency deviation by
400Hz signal.
Output level : as low as possible
set
speaker terminal
SECTION 3
ELECTRICAL ADJUSTMENTS
Put the lead-wire
antenna close to
the set.
0.01 µ F
antenna
terminal
JW6 (ICF-C201)
JW7 (ICF-C205)
level meter
8 Ω
• Repeat the procedures in each adjustment several times, and
the frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
CT4
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
confirm
CT2
ICF-C201/C205
ICF-C205
455kHz
ICF-C205
520kHz
1,650kHz
ICF-C205
600kHz
1,400kHz
ICF-C201/C205
86.5MHz
109.5MHz
86.5MHz
109.5MHz
7