hit counter script

Exhaust System Requirements; Fire Hazard - Frigidaire CAQE7021LW0 Installation Manual

Hide thumbs Also See for CAQE7021LW0:
Table of Contents

Advertisement

Available languages

Available languages

Exhaust
system
requirements
Use only 4 inch (102 mm) diameter rigid or flexible metal
duct and approved vent hood which has a swing-out
damper(s) that open when the dryer is in operation.
When the dryer stops, the dampers automatically close to
prevent drafts and the entrance of insects and rodents.
To avoid restricting the outlet, maintain a minimum of 12
inches (30.5 cm) clearance between the vent hood and
the ground or any other obstruction.
FIRE HAZARD
Failure to follow these instructions can create excessive
drying times and fire hazards.
The following
are specific requirements
for
proper and safe operation
of your dryer.
FIRE HAZARD
Do not install a clothes dryer with flexible plastic or
metal foil venting materials. Flexible venting materials
are known to collapse, be easily crushed and trap lint.
These conditions will obstruct clothes dryer airflow and
increase the risk of fire: ............................................................................................................................................................................................
:If your present system is made up of plastic duct or
metal foil duct, replace it with a rigid or semi-rigid metal
duct. Also, ensure the present duct is free of any lint prior
to installing dryer duct.
f
Correct
Correct
1i
Incorrect

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents