Page 2
For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed.
Page 3
USA only: This product has a fluorescent lamp that contains mercury. Disposal may be regulated in your community due to environmental considerations. For disposal or recycling information, please contact your local authorities or visit Panasonic website: http://www.panasonic.com/environmental or call 1-888-769-0149.
Page 4
These Panasonic ventilating fan models are listed by UL under UL file No. E78414. The lighting unit is an energy-saving, lighting device that uses two 13W fluorescent lamps and produces almost the same illumination as a standard 100W incandescent lamp.
Page 5
2 7/8 (73) 3 3/8 (85) 10 1/4 (260) 3 3/4 (94) Fan body Junction box Fluorescent lamp (Self-ballasted) ( LIGHT ) Black Live Power supply White Neutral AC120V 60Hz Night lamp Power supply Live Black AC120V 60Hz ( N.LIGHT ) Capacitor White White...
Page 6
(If using 3 inch round duct, please purchase the 26 gauge steel Panasonic 4" Oval - 3" Round Reducer from our representative.)(Fig.3)
Page 7
6. Finish ceiling work. Ceiling hole should be aligned with the inside edge of the flange. (Fig.4) 7. Remove the tape from mounting springs, lead wire, and night lamp before installation as shown below. Tape After finishing the ceiling job, fill gap between flange and ceiling with caulk or other sealant to prevent air leakage.
Page 8
WALL 1. Before installation, remove the tape from Stud damper and adaptor, and check that the damper can open and close smoothly. Then remove the accessory screws from suspension bracket. (Fig.1of page 6) 4 Long screws 2. Fix the flange of frame to stud by 2 long (ST4.0 x 30) screws(ST4.2x30), and fix the suspension bracket to stud by 2 long screws(ST4.2x30).
Page 9
Use non-abrasive kitchen detergent, wipe dry with clean cloth.)(Fig.13) 2. The grille should be dry after cleaning. Remove grille by pulling down the mounting spring in the right side of “Panasonic” logo. Remove dust and dirt from fan body using a vacuum cleaner. (Fig.14) Fig.14 4.
Page 10
Lighting unit Fig.17 1. Remove grille by pulling down the mounting spring in the right side of “Panasonic” logo. (Fig.16) 2.Remove plug connector then pull down the other mounting spring. (Squeeze mounting spring and pull down carefully.) (Fig.17)
Page 11
Properly insulate the area around the fan to minimize building heat loss and gain. (Fig.21) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Our fans and fan/light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor’s fan/light...