Craftsman 919.165361 Owner's Manual
Craftsman 919.165361 Owner's Manual

Craftsman 919.165361 Owner's Manual

Permanently lubricated portable air compressor

Advertisement

Available languages

Available languages

Quick Links

Owner's Manual
i (RRFTSMRNq
Permanently
Lubricated
Portable
AIR COMPRESSOR
Model No.
919.165361
Safety Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D30052
Revl
1/22/04

Advertisement

loading

Summary of Contents for Craftsman 919.165361

  • Page 1 Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D30052 Revl 1/22/04...
  • Page 2 HOW TO ORDER REPAIR PARTS ...... back cover ltl__1 ;| ;[_I_ hi" FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge.
  • Page 3: Glossary

    Model No. 919,165361 Max. Developed Running HP Bore 2.875" Stroke 1.25" Voltage-Single Phase 120V Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig Refer to Glossary for abbreviations.
  • Page 4 I I_ I_o] ;111P'.'q +IInl[,.'9'.,_ _1 _ &'i __JL_[,._)III,_]LI_+']IIT[_o _+]L_,[,._ Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment, ,l;1"l'J "-In WARNING: Risk of explosion or fire What Could Happen...
  • Page 5: Accessories

    WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury, What Could Haopen How To Prevent It Failure to properly drain condensed Drain tank daily or after each use.
  • Page 6 WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly it may cause electdc shock.
  • Page 7 WARNING: Risk of Burns How To Prevent It What Could Happen Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns. hot for several minutes after operation.
  • Page 8 WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) What Could Happen How To Prevent It Oil can leak or spill and could result in Always place COMPRESSOR on a fire or breathing hazard; serious injury or protective mat when transporting death can result, oil leaks will damage...
  • Page 9: Duty Cycle

    Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Installation

    IMPORTANT: The outlet being used HOW TO SET UP YOUR must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration dry and well ventilated area.
  • Page 11: Operation

    Extension Cords Voltage and Circuit Protection Refer to the specification chart for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit requirements. cords will cause voltage to drop resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 12 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. On/Auto/Off Switch Description of Operation Tank Pressure Gauge: The tank...
  • Page 13 Air Compressor Pump (not shown): Before First Start Up Compresses air into the air tank. _Risk of Unsafe Working air is not available until the Operation. Serious compressor has raised the air tank damage may result if the following pressure above that required at the break-in instructions are not air outlet.
  • Page 14 How to Start: Before Each Start-Up: Place On/Auto/Off lever to Turn the On/Auto/Off lever to "OFF". "AUTO" and allow tank pressure to build. Motor will stop when Turn the regulator knob counter- tank pressure reaches "cut-out" clockwise to set the outlet pressure.
  • Page 15 Customer Responsibilities Before Daily or _=ach after each LJSe Check Safety Valve • Drain Tank • To Drain Tank Risk of Unsafe Operation. Unit Set the On/Auto/Off lever to cycles automatically when power is "OFF". on. When servicing, you may be exposed to voltage sources, Turn the regulator knob counter- clockwise to set the outlet...
  • Page 16: Maintenance

    NOTE: The hose clamp is not ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST reusable. You must purchase a new BE PERFORMED BY A TRAINED hose clamp, see the Parts List SERVICE TECHNICIAN. Manual or purchase a standard hose clamp at a local hardware store. _Risk of Unsafe Unscrew the check valve (turn...
  • Page 17 NOTE: Arrow indicates flow of air. To Replace Regulator Make sure it is pointing in the Release all air pressure from air direction of air flow. tank. See "To Drain Tank" in the Maintenance section. Set the On/Auto/Off lever to "OFF"...
  • Page 18 Before you store the air compressor, Risk of Bursting. make sure you do the following: Water will condense in the air tank. If not Review the "Maintenance" drained, water will corrode and section on the preceding pages weaken the air tank causing a risk and perform scheduled of air tank rupture.
  • Page 19 d:{ollJ :] il ::F,."] -" [oIo]l III _[I _Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 20 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated )ressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 21 PROBLEM CAUSE CORRECTION Motor will not Check fuse box for blown Fuse blown, cimuitb_aker run. tdpped. fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse.
  • Page 22 ._ I-'I_o]_V_l *_ -'! _o] -II m] ¥,___,__ _ v Air Compressor Model Number 919.165361 Torqueto 10*20 in-lbs 3_' D30052 22- ENG...
  • Page 23 Air Compressor Model Number 919.165361 PART NUMBER DESCRIPTION Z-D26909 Tank SST-5314-1 Recess Rubber Bumper (3) 91895680 Screw (3) SSF-621 Screw (2) D30198 Nipple, 1/4-18 NPTX 2.50 AC-0430 Drain Valve D20114 Safety Valve CAC-4296-1 Regulator D20675 Quick Connect 1/4 NPT Z-D23004 Gauge 2"...
  • Page 24 Air Compressor Model Number 919.165361 Tigh_ Torque D30052 24_ ENG...
  • Page 25 Air Compressor Model Number 919.165361 PART NUMBER DESCRIPTION CAC-1320 Shroud (right) D25735 Shroud (left) D25877 Head CAC-1212 Tube Seal D22253 Outlet Tube Z-D24819 Head Gasket Z-D29777 Valve Plate Assembly SSG-8169 O-Ring +> Cylinder Sleeve SSF-3147 Screw, 3/8-16 UNC Socket Head >...
  • Page 26: Notes/Notas

    GARANT|A TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opei6n, Io reparar& o reemplazar& sin eosto alguno.
  • Page 27 Modelo N ° 919.165361 Max. HP desarrollado 1 HP Potencia de trabajo Di&metro interior 2,875 pulg. (73.0 mm) Carrera 1,25 pulg. (31,8 mm) 120V Voltaje-corriente manofAsica Circuito mfnimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 6 Galones (22,7 Iitros) Presi6n de eorte de entrada 120 psig Presi6n de corte de salida...
  • Page 28 GUARDE ESTAS INSTRUCCIONES La operaci6n o el mantenimiento inadecuados de este producto podrian ocasionar serias lesiones y dafios a la propiedad. Lea y comprenda todas las advertencias instrucciones de funcionamiento antes de utilizar este equipo. ',]=lm [_ ;{_ ADVERTENCIA: Riesgo de Explosi6n o Incendio qud puede occurrir cbmo...
  • Page 29 d=l![_;{q F 3%q ADVERTENCIA: Riesgo de Explosibn T_ue de aire: las siguientes condiciones podrian, causar el debilitamiento del tanque, determinar su explosibn violenta, dafios a la propiedad o serias lesiones. qud puede occurrir cbmo prevenirlo Drenaje inadecuado del agua condensada Drene el tanque diariamente o despu_s de...
  • Page 30 •,,l ::1 n nl [_1r,{q ADVERTENCIA: Riesgo de choque eldctrico qud puede occurrir cbmo prevenirlo Su compresor de aire est& accionado pot Jam_s opere el compresor a la intemperie electricidad. Como cua_quier otto dispositivo cuando est_ Iloviendo o en condiciones el_ctrico impu[sado e_'tricamente,...
  • Page 31 ",,1 =ltq [_ t,{_ ADVERTENCIA: Riesgo de Quemaduras qu_ puede occurrir cdmo prevenitlo Jam_is toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente despu_s del compresor o los tubos de sa_ida del de la operaci6n, el compresor permanecerd escape, puede ocasionarie...
  • Page 32 ADVERTENCIA: Riesgo de Serias Lesiones o Da_os a la Propiedad Transportar el Compresor (Fuego, inhalaci6n, da_o a la superficie de vehlculos) qud puede occurrir c6mo prevenido El aceite puede derramarse y e_lo podr{a Deposite el compresor sobre una atfombrilla resultar en serias lesiones o la muerte debido protectora cuando Io transporte= a fin de...
  • Page 33 Presibn minima de torte: Cuando el Familiarlcese con los siguientes terminos, motor esta apagado, la presion del tanque antes de operar la unidad: de aire baja a medida que usted continQa CFM: (Cubic feet per minute) Pies cQbicos usando su accesorio. Cuando la presion pot minuto.
  • Page 34 C6MO PREPARAR LA UNIDAD AsegQrese de que el tomacorriente que sera utilizado tenga la misma configaracion que el enchufe de Ubicacibn del compmsor de aire conexion a tierr& NO UTILtCE UN Ubique al compresor de aire en una zona ADAPTADOR. Vet figura, limpia>seca y bien ventilada.
  • Page 35 Cables de extensibn eldctrica Proteccibn del voltaje y del circuito NO se recomienda la utilizaci6n de cables Acerca del voltaje y la minima cantidad de de extensi6a electrica. El uso de cables circuitos req_._eridos,refierase al cuadro de especificaciones+ de extensi6n electrica originar& una cafda de tensi6n, Io que determinar&...
  • Page 36 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD, Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubieaci6n de los distintos controles y regulaciones Conserve este manual para referencias futuras.
  • Page 37 Bomba de compresibn del aire (no Cbmo utilizar su unidad mostrada): Compdme el aire clentro clel C6mo detenerla: tanque. El aire de trabajo no se encuentra disponible hasta que el compresor haya Riesgo de alcanzado a Ilenar el tanque hasta un nivel Operacibn de presidn por encima del requerido para...
  • Page 38 Mise en marche : Avant chaque mise en marche : Placez le levier "On/Auto/Off" & la Placez le levier "On/Auto/Off" & la position "OFF". position "AUTO" et attendez jusqu'& ce que la pression augmente< Le Gire la perilla del regulador moteur s'arr6tera Iorsque lapression contre el sentido del reloj pare...
  • Page 39 lwff:l _bi _ _1hVlll_ _I I[I Responsabilidades del cliente Antes [_aria_e_te carla 0 luego de cadauso Verifique la vAlvula de seguridad Drenaje del tanque • Cbmo drenar el tanque Riesgo de Operaci6n Coloque la palanca On/Auto/Off en la Insegura. La unidad arranca posici6n "OFF".
  • Page 40 TODO TIPO DE MANTENIMIENTO NOTk La abrazaderade la manguerano es OPERACIONES DE REPARACION NO reutilizable.Debera comprarse una nueva MENCIONADOS, DEBEPJ_N SER abrazadera,ver Is lists de parles del manual o EFECTUADOS POR PERSONAL TECNICO compre una abrazaderaestandar en cualquier ESPECIALIZADO, comercio de fetreterfa. Desenrosquela v_Jvula reguladors (gireen Riesgo de Operacibn...
  • Page 41 Para reemplazar el regulador NOTA: La flecha indica eI sentido de1flujo del aire. Aseg_rese que est_ apuntando a la Libere toda la presi6n del aire del tanque. direcciSn en la que fluye el air& Vea "Drenaje del tanque" en la secci6n "Mantenimiento'L Apagar la unidad colocando interruptor en On/Auto/OFF...
  • Page 42 Antes de guarder su compresor de aire, Riesgo de Explosibn. El asegQrese de haeer Io siguiente: agua se condensa dentro del tanque de Revise la secci6n "Mantenimiento" aire. Si no se drene, ella corroera de las p&ginas precedentes y ejecute debilitando la paredes del tenque de el mantenimiento...
  • Page 43 [_l_.,_ Im] _ I m] p ';l_] Z [T_"-]lli[o,,[o] I m] " _ I _ :To]:] nil = 1 i_Y;%,."] Riesgo de Operacibn Insegura. La unidad arranca automdticamente cuando esta enehufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire compdmido o a piezas movibles.
  • Page 44 PROBLEMA CORRECCI6N CAUSA Si hubiese una caida excesiva de La lectura de la Es normal que ocurra algt_n presion durante el uso del descenso en la presi6n. presi6n sobre un aooesorio, ajuste el regulador de man6metro aouerdo alas instrucciones de la viene equipado secci6n Operaci6n.
  • Page 45 CORRECCI6N PROBLEMA CAUSA El motor no Fusible fundido;interruptor Vedfiquela caja de fusibtse observando funciona. automaticodel circuitodisparado, la existencia de fusibles fundidos y sustitQyalosen case de necesidad. Restablezca el interruptor automatico. No use un fusible o interruptorautom_ico con valoresque excedan los sepecificados papala rarnade su circuito, Verifique el uso del fusible adecuado,...
  • Page 46 D30052 46- S P...
  • Page 47: Repair Protection Agreements

    Agreements Reparaciones Congratulations on making a smart Felicitaciones per hater una compra purchase. Your new Craftsman '_ product is inteligente, Su nueva unidad Craftsman ® est& designed and manufactured for years of diseffada y fabricada para afros de operaci6n dependable operation.
  • Page 48 Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.