EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-HF15000L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-HF15000L - 15000 Lumens

  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-HF15000L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-HF15000L Expand Serial Command Functional Specifications CONTENTS Overview ........................10 1ÿ 2ÿ Serial Interface Specification..................10 2.1 Transfer Specification ....................10 2.2 Connection .........................10 3ÿ Notes for communication....................10 4ÿ Notation.........................12 5ÿ Functional Execution Command Table..............13 5.1 Image Command Table....................13 5.2 PC Control Command Table ..................13 5.3 Input Control Command Table .................14 5.4 Screen Command Table....................14 5.5 Lamp Command Table ....................14...
  • Page 3 PLC-HF15000L Expand Serial Command Functional Specifications 8.4.11 CF_SHARP Command ..................24 8.4.12 CF_GAMMA Command..................25 8.4.13 CF_NZRED Command ..................25 8.4.14 CF_PROGV Command..................25 8.4.15 CF_IMAGE Command..................26 8.4.16 CF_IMAGEADJ Command................26 8.4.17 CF_ADVCOL Command..................27 8.5 PC Control Command ....................28 8.5.1 CF_FSYNC Command..................28 8.5.2 CF_TDOTS Command..................28 8.5.3 CF_H-POS Command ..................28 8.5.4 CF_V-POS Command..................29 8.5.5 CF_CLAMP Command..................29...
  • Page 4 PLC-HF15000L Expand Serial Command Functional Specifications 8.8 Lamp Command......................41 8.8.1 CF_LAMPMODE Command................41 8.8.2 CF_ LAMPCONSTTAR Command..............41 8.8.3 CF_AUTOLAMPCONTRL Command ..............41 8.8.4 CF_LAMPLIFECONTRL Command..............42 8.8.5 CF_LAMPINTERVAL Command.................42 8.9 Setting Command ......................43 8.9.1 CF_LANG Command...................43 8.9.2 CF_ MENUPOSITION Command................43 8.9.3 CF_MENUSIZE Command ..................43 8.9.4 CF_DISP Command ....................44 8.9.5 CF_BACKGND Command ..................44 8.9.6 CF_PIP Command ....................44...
  • Page 5 PLC-HF15000L Expand Serial Command Functional Specifications 8.9.34 CF_CMSTORE Command.................52 8.9.35 CF_CMMSTESTPAT Command................53 8.9.36 CF_CMTGTESTPAT Command ................53 8.9.37 CF_CMFDEFAULT Command ................53 8.9.38 CF_CMMENUOFF Command ................53 8.9.39 CF_CMMENU Command ..................54 8.9.40 CF_HDMISETUP Command ................54 8.9.41 CF_LOGO Command ..................54 8.9.42 CF_FILCTL Command ..................55 8.9.43 CF_FANSPEED Command ................55 8.9.44 CF_RCODE Command..................55 8.9.45 CF_RSENS Command ..................55...
  • Page 6 PLC-HF15000L Expand Serial Command Functional Specifications 9.1 Format.........................64 9.2 Transfer Example.......................64 9.3 Operation condition....................64 9.4 Image Status Read Commands................65 9.4.1 CR_CONT Command ..................65 9.4.2 CR_BRIGHT Command ..................65 9.4.3 CR_COLOR Command ..................65 9.4.4 CR_TINT Command ....................65 9.4.5 CR_APCTRL Command..................65 9.4.6 CR_COLTEMP Command...................66 9.4.7 CR_WBAL-R Command..................66 9.4.8 CR_WBAL-G Command ..................66 9.4.9 CR_WBAL-B Command..................66...
  • Page 7 PLC-HF15000L Expand Serial Command Functional Specifications 9.7.5 CR_MODELIST Command..................76 9.7.6 CR_SRCINP1 Command..................76 9.7.7 CR_SRCINP2 Command..................76 9.7.8 CR_SRCINP3 Command..................77 9.7.9 CR_SRCINP4 Command..................77 9.7.10 CR_HMSLOT Command ...................77 9.7.11 CR_NMSLOT1 Command .................77 9.7.12 CR_NMSLOT2 Command .................77 9.7.13 CR_NMSLOT3 Command .................78 9.7.14 CR_NMSLOT4 Command .................78 9.7.15 CR_IDSLOT1 Command ...................78 9.7.16 CR_IDSLOT2 Command ...................78 9.7.17 CR_IDSLOT3 Command ...................79...
  • Page 8 PLC-HF15000L Expand Serial Command Functional Specifications 9.10.1 CR_LANG Command ..................86 9.10.2 CR_MENUSIZE Command................86 9.10.3 CR_DISP Command..................86 9.10.4 CR_BACKGND Command................86 9.10.5 CR_PIP Command.....................87 9.10.6 CR_PIPADJ Command..................87 9.10.7 CR_PIPMODE Command..................87 9.10.8 CR_PIPMAININP Command ................88 9.10.9 CR_PIPSUBINPU Command ................88 9.10.10 CR_PIPSIZE Command ..................89 9.10.11 CR_PIPFRAMELOCK Command ..............89 9.10.12 CR_PIPSTORE Command ................89 9.10.13 CR_EDGEBLENDING Command ..............89...
  • Page 9 PLC-HF15000L Expand Serial Command Functional Specifications 9.10.41 CR_SHUTH Command..................96 9.10.42 CR_SHUTEFFECT Command ................96 9.10.43 CR_SHUTRELEASE Command ..............96 9.10.44 CR_DELAYCTRL Command................96 9.10.45 CR_CCAPTIONSIDP Command..............97 9.10.46 CR_CCAPTIONCOLOR Command ..............97 9.10.47 CR_FILH Command ..................97 9.10.48 CR_FILCOND Command ................97 9.10.49 CR_FILREPL Command .................97 9.10.50 CR_FILREMAIN Command................98 9.10.51 CR_FILTIMER Command................98 9.10.52 CR_FILCLEANTIMER Command ..............98 9.10.53 CR_PTIMEMODE Command ................98...
  • Page 10: 1Ÿ

    PLC-HF15000L Expand Serial Command Functional Specifications Overview 1ÿ 0û This Functional Specification defines communication for PLC-HF15000L. 0û Most commands are also available to remote-control a projector through RS-232C from a computer. Therefore, commands are defined as Expand Serial Commands. 0û The operation by some commands depends on Optional Board installed in Input Slot of the projector.
  • Page 11 PLC-HF15000L Expand Serial Command Functional Specifications 0û Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). 0û When a projector receives carriage return (0x0D), it starts decoding. 0û There are two types of commands as below: Example of Functional Execution Command:”CF_BRIGHT_032”...
  • Page 12: Notation

    PLC-HF15000L Expand Serial Command Functional Specifications Notation 4ÿ 0û Data from a controller to a projector is represented as COMMAND, and data from a projector to a controller in response to the incoming command is represented as RESPONSE. 0û [CR]: Carriage Return Code The command ends with carriage return code.
  • Page 13: Functional Execution Command Table

    PLC-HF15000L Expand Serial Command Functional Specifications Functional Execution Command Table 5ÿ 5.1 Image Command Table Execute command Item CF_CONT_%1[CR] Set value of Contrast CF_BRIGHT_%1[CR] Set value of Brightness CF_COLOR_%1[CR] Set value of Color CF_TINT_%1[CR] Set value of Tint CF_COLMNSAV_%1[CR] Set area to store current values of Color Management CF_COLMNLD_%1[CR] Set area to load values of Color Management CF_APCTRL_%1[CR]...
  • Page 14: Input Control Command Table

    PLC-HF15000L Expand Serial Command Functional Specifications 5.3 Input Control Command Table Execute command Item CF_INPUT_%1[CR] Select Input CF_SOURCE_%1[CR] Select Source of selected Input CF_INPUT1_%1[CR] Select Input1 and also set input source to %1 CF_INPUT2_%1[CR] Select Input2 and also set input source to %1 CF_INPUT3_%1[CR] Select Input3 and also set input source to %1 CF_INPUT4_%1[CR]...
  • Page 15 PLC-HF15000L Expand Serial Command Functional Specifications Select Input and Source of Sub picture for “Picture in CF_PIPSUBINP_%1_%2[CR] Picture” CF_PIPSIZE_&1[CR] Set size of Main /Sub picture for “Picture in Picture” CF_PIPSIZEMAIN_&1[CR] Set size of Main picture for “Picture in Picture” CF_PIPSIZESUB_&1[CR] Set size of Sub picture for “Picture in Picture”...
  • Page 16: Other Command Table

    PLC-HF15000L Expand Serial Command Functional Specifications CF_PTIME_%1[CR] Set the time for count down mode in P-timer function CF_KEYDIS_%1[CR] Set limitation of RC/KEY control CF_FDEFAULT_%1[CR] Return the settings to Factory Default status CF_SHUTRCPROT_%1[CR] Set valid / invalid of RC use on Shutter control function Set valid / invalid use of key on the side panel on CF_SHUTKEYPROT_%1[CR] Shutter control function...
  • Page 17: Status Read Command Table

    PLC-HF15000L Expand Serial Command Functional Specifications Status Read Command Table 6ÿ 6.1 Image Status Read Command Table Status read command Item CR_CONT [CR] Get value of Contrast CR_BRIGHT [CR] Get value of Brightness CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_APCTRL Get setting status of Auto Picture Control...
  • Page 18: Screen Status Read Command Table

    PLC-HF15000L Expand Serial Command Functional Specifications CR_SRCINP1 [CR] Get selected source for Input 1 CR_SRCINP2 [CR] Get selected source for Input 2 CR_SRCINP3 [CR] Get selected source for Input 3 CR_SRCINP4 [CR] Get selected source for Input 4 CR_HMSLOT [CR] Get the total number of Slots CR_NMSLOT1 [CR] Get a card name inserted to Slot 1...
  • Page 19: Setting Status Read Command Table

    PLC-HF15000L Expand Serial Command Functional Specifications 6.7 Setting Status Read Command Table Status read command Item CR_LANG [CR] Get selected language CR_MENUSIZE [CR] Get setting status of Menu size CR_DISP [CR] Get setting status of Display CR_BACKGND [CR] Get setting status of Screen for no signal CR_LOGO [CR] Get setting status of Logo CR_LOGOLOCK [CR]...
  • Page 20: Other Status Read Command Table

    PLC-HF15000L Expand Serial Command Functional Specifications CR_BLENDBLK[CR] Get setting status of Black level of Edge blending CR_BLENDTESTPAT[CR] Get setting status of Test pattern of Edge blending CR_COLORMATCHING[CR] Get setting status of Color matching CR_CMMSXY_%1[CR] Get “x”,”y” value of Measured of Color matching CR_CMMSL_%1[CR] Get “L”...
  • Page 21: Functional Execution Command

    PLC-HF15000L Expand Serial Command Functional Specifications Functional Execution Command 8ÿ 8.1 Format 1) PC issues a command in the format below: Pattern1: “CF_Command” [CR] Pattern2: “CF_Command_” %1 [CR] CF_: Header Command: String %1: Parameter (String) _: Space (To separate Command and Parameter) 2) The projector decodes the received command and when it gets ready to receive another command, it returns the response.
  • Page 22: Image Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_ CONT Command Command “CF_CONT_%1” [CR] “000-063”--------------- Directly specify setting value of Contrast “UP”--------------------- Increment setting value of Contrast by 1 “DN”--------------------- Decrement setting value of Contrast by 1 Set user controlled value of Contrast. (Available only in the normal Power ON status) Details The value set by this command is not stored in the projector.
  • Page 23: Cf_Colmnsav Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.5 CF_COLMNSAV Command Command “CF_COLMNSAV_%1” [CR] “000 – 009” ---------------- Specify the area to store Store current setting status of Color Management to the area specified in %1. Details (Available only in the normal Power ON status) Acceptable “000”...
  • Page 24: Cf_Wbal- Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.9 CF_WBAL- Command Command “CF_WBAL-%1_%2” [CR] “R” ------------- RED “G” ------------ GREEN “B” ------------- BLUE “000-063”------ Directly specify value of Color selected in %1 of White Balance. “UP”------ Increment setting value of Color specified in %1 of White Balance by 1 “DN”----- Decrement setting value of Color specified in %1 of White Balance by 1 Set value of Color specified in %1 of White Balance (Available only in the normal Power ON status)
  • Page 25: Cf_Gamma Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.12 CF_GAMMA Command Command “CF_GAMMA_%1” [CR] “000-015” ---------------- Directly specify setting value of Gamma “UP”---------------------- Increment setting value of Gamma by 1 “DN”---------------------- Decrement setting value of Gamma by 1 Set user controlled value of Gamma. (Available only in the normal Power ON status) Details The value set by this command is not stored in the projector’s memory.
  • Page 26: Cf_Image Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.15 CF_IMAGE Command Command “CF_IMAGE__%1” [CR] “STAND” ----------- Standard (Image adjustment value is set to factory default) “REAL” ------------- Real (Fixed value to display graphic image with natural tone) “CINEMA” --------- Cinema (Fixed value to focus on tone reproduction for movie) “DYNAMIC”...
  • Page 27: Cf_Advcol Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.4.17 CF_ADVCOL Command Command “CF_ADVCOL_%1” [CR] “AUTO” -------------- Set Advanced color to Auto “OFF” ----------------- Set Advanced color OFF. “UP” ----------- The same operation as pressing Up key or Left key “DN” -----------The same operation as pressing Down key or Right key *”UP”...
  • Page 28: Pc Control Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.5 PC Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) The value set by this command is not stored in the projector’s memory.
  • Page 29: Cf_V-Pos Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.5.4 CF_V-POS Command Command “CF_V-POS_%1” [CR] “0000-nnnn” ------------ Directly specify setting value of Vertical Position “nnnn” indicates maximum value, which is current (Total Line – Display Area V) value “UP” --------------------- Increment setting value of Vertical Position by 1 “DN”...
  • Page 30: Cf_Dline Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
  • Page 31: Cf_Pcstore Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.5.9 CF_PCSTORE Command Command “CF_PCSTORE_%1” [CR] “MODE1” --------------------------- Store current PC Adjust status to Mode1 “MODE2” --------------------------- Store current PC Adjust status to Mode2 “MODE3” --------------------------- Store current PC Adjust status to Mode3 “MODE4” --------------------------- Store current PC Adjust status to Mode4 “MODE5”...
  • Page 32: Input Control Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command “CF_INPUT_%1” [CR] “1” ---------------------------------- Select Input 1 “2” ---------------------------------- Select Input 2 “3” ---------------------------------- Select Input 3 "4” ---------------------------------- Select Input 4 “UP”-------------------------------- Increment Input No. by 1 “DN”-------------------------------- Decrement Input No.
  • Page 33: Cf_Input1~4 Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.6.3 CF_INPUT1~4 Command Command “CF_INPUT%1_%2” [CR] “1” ------------------------------------ Specify Input 1 “2” ------------------------------------ Specify Input 2 “3” ------------------------------------ Specify Input 3 “4” ------------------------------------ Specify Input 4 “DIGITAL” ---------------- Select DVI Input (Computer signal) “ANALOG” --------------- Select Analog Input (Computer signal) “VIDEO”...
  • Page 34 PLC-HF15000L Expand Serial Command Functional Specifications “D-XGA1” --------------------- Select D-XGA1 “D-WXGA3”------------------- Select D-WXGA3 Input is “D-1080I” --------------------- Select D-1080i HDMI “D-575p” ----------------------- Select D-575p “D-480p” ----------------------- Select D-480p “AUTO” -------------------------- Select System “Auto” “1080P” --------------------------- Select 1080p “1080I” --------------------------- Select 1080i “1035I”...
  • Page 35: Screen Control Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command “CF_SCREEN_%1” [CR] “NORMAL” ---------------------- Select Normal mode “FULL” --------------------------- Select Full mode “WIDE” --------------------------- Select Wide (16:9) mode “ZOOM” ------------------------- Select Zoom mode “TRUE” -------------------------- Select True mode Input is “CUSTOM”...
  • Page 36: Cf_Keystone Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
  • Page 37: Cf_Corner-Dl Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.6 CF_CORNER-DL Command Command “CF_CORNER-DL%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
  • Page 38: Cf_Ceil Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.10 CF_CEIL Command Command “CF_CEIL_%1” [CR] “ON” --------------------------- Set Ceiling to ON “OFF” ------------------------- Set Ceiling to OFF Set/Cancel Ceiling. (Valid only when in the normal Power ON status.) When Ceiling is set to ON, image is left/right as well as top/bottom reversed. Details The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status.
  • Page 39: Cf_Vpos Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.13 CF_VPOS Command Command “CF_VPOS_%1” [CR] “015” --------------------- +15 “014” --------------------- +14 ÿ “001” --------------------- +1 “000” --------------------- ±0 “ 01” --------------------- 1 ÿ “ 14” --------------------- 14 “ 15” --------------------- 15 “UP” --------------------- Increment setting value of Vposition by 1 “DN”...
  • Page 40: Cf_Hpos Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.7.15 CF_HPOS Command Command “CF_HPOS_%1” [CR] “015” --------------------- +15 “014” --------------------- +14 ÿ “002” --------------------- +2 “001” --------------------- +1 “000” --------------------- ±0 “ 01” --------------------- 1 “ 02” --------------------- 2 ÿ “ 14” --------------------- 14 “...
  • Page 41: Lamp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “4LAMP” ------------- Set lamp mode to 4-lamps “3LAMPAUTO” ---- Set lamp mode to 3-lamps and automatically and preferentially use lamps with shorter cumulated lighting time. “3LAMP123”...
  • Page 42: Cf_Lamplifecontrl Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.8.4 CF_LAMPLIFECONTRL Command Command “CF_LAMPLIFECONTRL_%1” [CR] “MODE1” -------------------------- Set Lamp life control mode to Mode1 “MODE2” -------------------------- Set Lamp life control mode to Mode2 Select Lamp life control. (Valid only when in the normal Power ON status.) Details The value set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status.
  • Page 43: Setting Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9 Setting Command 8.9.1 CF_LANG Command Command “CF_LANG_%1” [CR] “ENG” --------------------------- Select ENGLISH “DEU” --------------------------- Select German “FRA” --------------------------- Select French “ITA” ----------------------------- Select Italian “ESP” ---------------------------- Select Spanish “POR” --------------------------- Select Portuguese “NED” --------------------------- Select Dutch “SVE”...
  • Page 44: Cf_Disp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.4 CF_DISP Command Command “CF_DISP_%1” [CR] “ON” ----------------------------- Set Display to ON “CNTDWNOFF” -------------- Set Display to Count down Off “OFF” --------------------------- Set Display to OFF “UP” ----------- The same operation as pressing Up key or Left key “DN”...
  • Page 45: Cf_Pipmaininp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.8 CF_PIPMAININP Command Command “CF_PIPMAININP_%1_%2” [CR] “1” -------------------- Select Input 1 “2” -------------------- Select Input 2 “3” -------------------- Select Input 3 “4” -------------------- Select Input 4 “DIGITAL” ---------------- Select DVI Input “ANALOG” --------------- Select Analog Input “VIDEO”...
  • Page 46: Cf_Pipsize Command

    PLC-HF15000L Expand Serial Command Functional Specifications Select input and source of Sub picture of “Picture in Picture”. (Valid only when in the normal Power ON status.) * In the case of a specific status, return Error Code “101” [CR] and the command is Details not executed.
  • Page 47: Cf_Pipposition Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.13 CF_PIPPOSITION Command Command “CF_PIPPOSITION_%1” [CR] “POS1” -------------------- Move main picture position to up “POS2” -------------------- Move main picture position to down “POS3” -------------------- Move main picture position to left “POS4” -------------------- Move main picture position to right “POS5”...
  • Page 48: Cf_Pipmodefree Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.16 CF_PIPMODEFREE Command Command “CF_PIPMODEFREE_%1” [CR] “USER1” --------------------------- Set User1 to Free status “USER 2” -------------------------- Set User2 to Free status “USER 3” -------------------------- Set User3 to Free status “USER 4” -------------------------- Set User4 to Free status “USER 5”...
  • Page 49: Cf_Blendstart Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.20 CF_BLENDSTART Command Command “CF_BLENDSTART_%1_%2” [CR] “LEFT” ---------------------- Left side “RIGHT” -------------------- Right side “TOP” ----------------------- Upper side “BOTTOM” ---------------- Lower side “000”-“1024”-------------------- Directly specify value of direction of %1 *Value of upper limit changes by choice of %1 Left ---------------------- 000~1024 Right -------------------- 000~1024 Top ---------------------- 000~540...
  • Page 50: Cf_Blendtestpat Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.23 CF_BLENDTESTPAT Command Command “CF_BLENDTESTPAT_%1” [CR] “ON” ---------------------- Set to On “OFF” -------------------- Set to Off Set Test pattern of Edge blending.(Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
  • Page 51: Cf_Cmmsxy Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.28 CF_CMMSXY Command Command “CF_CMMSXY_%1_%2_%3” [CR] “RED” ---------------------- Set value of Red “GREEN” ----------------- Set value of Green “BLUE” -------------------- Set value of Blue “0000” – “1000” --------- Directly specify “x” value of color of %1 “0000”...
  • Page 52: Cf_Cmtgg Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.31 CF_CMTGG Command Command “CF_CMTGG_%1_%2” [CR] “RED” ---------------------- Set value of Red “GREEN” ----------------- Set value of Green “BLUE” -------------------- Set value of Blue “WHITE” ------------------ Set value of White “CYAN” -------------------- Set value of Cyan “MAGENTA”...
  • Page 53: Cf_Cmmstestpat Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.35 CF_CMMSTESTPAT Command Command “CF_CMMSTESTPAT_%1” [CR] “RED” ---------------------- Display Red “GREEN” ------------------ Display Green “BLUE” -------------------- Display Blue “OFF” --------------------- Do not show test pattern display Display Test pattern of Measured of Color matching. Details (Available only in the normal Power ON status) Acceptable...
  • Page 54: Cf_Cmmenu Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.39 CF_CMMENU Command Command “CF_CMMENU_%1” [CR] “ON” ---------------------- Display Advanced color matching menu “OFF” --------------------- Set Advanced color matching menu undisplayed. Set Advanced color matching menu displayed or undisplayed. Details (Available only in the normal Power ON status) Acceptable “000”...
  • Page 55: Cf_Filctl Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.42 CF_FILCTL Command Command “CF_FILCTL_%1” [CR] “SKD” --------------- Schedule filter cleaning task Details Schedule filter cleaning Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.9.43 CF_FANSPEED Command Command “CF_FANSPEED_%1” [CR] “MAX” ---------------------------- Select Maximum speed of Fan Control “NOR”...
  • Page 56: Cf_P-Mane Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.46 CF_P-MANE Command Command “CF_P-MANE_%1” [CR] “OFF” ---------------------------------- Set Power Management to Off “READY” ----------------------------- Set Power Management to Ready “SHUTDOWN” --------------------- Set Power Management to Shut Down mode “UP” ----------- The same operation as pressing Up key or Left key “DN”...
  • Page 57: Cf_Pjpincode Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.50 CF_PJPINCODE Command Command “CF_PJPINCODE_%1” [CR] “0000 – 9999” ------------- Directly specify PJ PIN code Enter PIN code to cancel PIN code lock (Available only in the normal Power ON status) PIN code can not be changed. (Only PIN code lock is canceled.) *When PIN code Lock is enabled: PIN code is matched ------------------------- Command is valid (Acceptable) PIN code is mismatched -------------------- Command is invalid (Error code “102”)
  • Page 58: Cf_Shuteffect Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.54 CF_SHUTEFFECT Command Command “CF_SHUTEFFECT_%1” [CR] “OFF” --------Disable fade in and out function of Shutter “L1” --------- Set fade in and out function of Shutter to L1 “L2” --------- Set fade in and out function of Shutter to L2 Set Effect function of Shutter.
  • Page 59: Cf_Ccaptioncolor Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.58 CF_CCAPTIONCOLOR Command Command “CF_CCAPTIONCOLOR _%1” [CR] “COLOR” ------- Select Color “WHITE” -------- Select White Select color of Closed caption. The status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF.
  • Page 60: Cf_ Ptimemode Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.62 CF_ PTIMEMODE Command Command “CF_PTIMEMODE_%1” [CR] “COUNTUP” ---------------------- Set P-timer to Count up mode “COUNTDN” ---------------------- Set P-timer to Count down mode Select count up/down mode of P-timer. (Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status.
  • Page 61: Cf_Fdefault Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.9.66 CF_FDEFAULT Command Command “CF_FDEFAULT_%1” [CR] “RST” Return the settings to Factory Default status (Valid only when in the normal Power Details ON status) Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 61/105...
  • Page 62: Other Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.10 Other Command 8.10.1 CF_KEYEMU Command Command “CF_KEYEMU_%1” [CR] “RIGHT” ---------------- Move Pointer rightward in On-Screen Display Menu “LEFT” ------------------ Move Pointer leftward in On-Screen Display Menu “UP” ---------------------- Move Pointer to upward On-Screen Display Menu “DN”...
  • Page 63: Cf_Power Command

    PLC-HF15000L Expand Serial Command Functional Specifications 8.10.3 CF_POWER Command Command “CF_POWER_%1” [CR] “ON” ----------------------------- Power ON “OFF” --------------------------- Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed.
  • Page 64: Status Read Command

    PLC-HF15000L Expand Serial Command Functional Specifications Status Read Command 9ÿ 9.1 Format PC issues a command in the format below: “CR_Command” [CR] Command: String When the projector receives the applicable command, it returns the required information as a data string. “000_”...
  • Page 65: Image Status Read Commands

    PLC-HF15000L Expand Serial Command Functional Specifications 9.4 Image Status Read Commands 9.4.1 CR_CONT Command Command “CR_CONT” [CR] Details Get user controlled value of Contrast Acceptable “000_%1” [CR] Response “000” – “063” Unacceptable “?” [CR] 9.4.2 CR_BRIGHT Command Command “CR_BRIGHT” [CR] Details Get user controlled value of Brightness Acceptable...
  • Page 66: Cr_Coltemp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.4.6 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1” [CR] “000” ~“003” Response “BLANK” ---- OSD Menu is blank (Neither of Xlow / Low / Mid / High) Unacceptable “?”...
  • Page 67: Cr_Offset-B Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.4.12 CR_OFFSET-B Command Command “CR_OFFSET-B” [CR] Details Get user controlled Blue value of Offset Acceptable “000_%1” [CR] Response “000” – “063” Unacceptable “?” [CR] 9.4.13 CR_SHARP Command Command “CR_SHARP” [CR] Details Get user controlled value of Sharpness Acceptable “000_%1”...
  • Page 68: Cr_Image Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.4.17 CR_IMAGE Command Command “CR_IMAGE” [CR] Get image setting status. Details The Required data “CUSTOM1” – “CUSTOM10” corresponds to “Image1” – “Image10” displayed when selecting Image on OSD Menu. Acceptable “000_%1” [CR] “STAND” ---------------------------------- Standard “REAL”...
  • Page 69: Pc Status Read Commands

    PLC-HF15000L Expand Serial Command Functional Specifications 9.5 PC Status Read Commands 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] Response “0000” – “0031” “Error Code” [CR] -------------- When command is invalid in the Unacceptable given condition (such as being selected input) “?”...
  • Page 70: Cr_Clamp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.5.5 CR_CLAMP Command Command “CR_CLAMP” [CR] Details Get value of Clamp Acceptable “000_%1” [CR] “0000” – “ 4095” Response “Error Code” [CR] -------------- When command is invalid in the Unacceptable given condition (such as being selected input) “?”...
  • Page 71: Cr_Orgmode Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-60 is not selected, get the current signal. Acceptable “000_%1”...
  • Page 72: Video Status Read Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get currently selected signal. Details Value only when Input is video. (Invalid when Input is computer) Acceptable “000_%1” [CR] “1080PSF/24” ------- 1080psf 24Hz “1080P60”...
  • Page 73: Input Read Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.7 Input Read Command 9.7.1 CR_INPUT Command Command “CR_INPUT” [CR] Details Get selected INPUT No. Acceptable “000_%1” [CR] Response “1” – “4” Unacceptable “?” [CR] 9.7.2 CR_SOURCE Command Command “CR_SOURCE” [CR] Details Get selected Source Acceptable “000_%1”...
  • Page 74: Cr_System Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.3 CR_SYSTEM Command Command “CR_SYSTEM” [CR] Details Get selected System Response Acceptable “000_%1” [CR] “VGA1” ------------------------- indicates VGA1 is selected “VGA2” ------------------------- indicates VGA2 is selected “XGA1” ------------------------- indicates XGA1 is selected “WXGA3” ---------------------- indicates WXGA3 is selected “1080I”...
  • Page 75: Cr_ Syslist Command

    PLC-HF15000L Expand Serial Command Functional Specifications “AUTO” ------------------- indicates Auto is selected “NTSC” ------------------- indicates NTSC is selected “NTSC443” -------------- indicates NTSC4.43 is selected “PAL” ---------------------- indicates PAL is selected Input is Video “SECAM” ----------------- indicates SECAM is selected or S-video “PAL-M”...
  • Page 76: Cr_Modelist Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.5 CR_MODELIST Command Command “CR_MODELIST” [CR] Details Get possible modes for Mode list Acceptable “000_%1_%2_---_%x” [CR] Error Code “101” is returned except for PC-Analog and for no signal with PC-Analog Possible modes in Mode1-10 are returned when PC-Analog signal is coming.
  • Page 77: Cr_Srcinp3 Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.8 CR_SRCINP3 Command Command “CR_SRCINP3” [CR] Details Get Source of Input 3 Acceptable “000_%1” [CR] Response The same data as CF_SRCINP1 Unacceptable “?” [CR] 9.7.9 CR_SRCINP4 Command Command “CR_SRCINP3” [CR] Details Get Source of Input 4 Acceptable “000_%1”...
  • Page 78: Cr_Nmslot3 Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.13 CR_NMSLOT3 Command Command “CR_NMSLOT3” [CR] Details Get the board name inserted to Slot 3 Acceptable “000_%1” [CR] Response The same data as CR_NMSLOT1 Unacceptable “?” [CR] 9.7.14 CR_NMSLOT4 Command Command “CR_NMSLOT4” [CR] Details Get the board name inserted to Slot 4 Acceptable “000_%1”...
  • Page 79: Cr_Idslot3 Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.7.17 CR_IDSLOT3 Command Command “CR_IDSLOT3” [CR] Get ID information on Slot 3. This command is to recognize the inserted slot board Details and specify the valid Input source. Acceptable “000_%1” [CR] Response The same as CR_IDSLOT1 Unacceptable “?”...
  • Page 80: Screen Status Read Commands

    PLC-HF15000L Expand Serial Command Functional Specifications 9.8 Screen Status Read Commands 9.8.1 CR_SCREEN Command Command “CR_SCREEN” [CR] Details Get currently selected screen image size Acceptable “000_%1” [CR] “NORMAL” ---------------------- Normal mode “WIDE” --------------------------- Wide(16:9) mode “ZOOM” -------------------------- Zoom mode “NATURAL” -------------------- Natural wide mode Response “FULL”...
  • Page 81: Cr_Rear Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.8.5 CR_REAR Command Command “CR_REAR” [CR] Details Get setting status of Rear function Acceptable “000_%1” [CR] “ON” --------------------------- Rear projection is enabled Response “OFF” ------------------------- Rear projection is disabled Unacceptable “Error Code” [CR] 9.8.6 CR_VSCALE Command Command “CR_VSCALE”...
  • Page 82: Cr_Screenaspect Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.8.10 CR_SCREENASPECT Command Command “CR_SCREENASPECT”[CR] Details Get status of Screen aspect Acceptable “000_%1” [CR] “FULL” ÿ e ÿ e ÿ e ÿ e ÿ e ÿ e ÿ e Select Full screen mode “43MODE” ÿ...
  • Page 83: Lamp Status Read Commands

    PLC-HF15000L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Commands 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get the information of Lamp Replacement time Acceptable “000_%1” [CR] “4****” 4 ---------------- indicates 4 lamps are used in this model. * ---------------- indicates the status of each lamp in lamp number order.
  • Page 84: Cr_Autolampcontrl Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.9.5 CR_AUTOLAMPCONTRL Command Command “CR_AUTOLAMPCONTRL” [CR] Details Get selected Lamp control mode Acceptable “000_%1” [CR] “NORMAL” ---------- NORMAL is selected. “ECO1” --------------- ECO1 is selected. Response “ECO2” --------------- ECO2 is selected. “AUTO” -------------- AUTO is selected. Unacceptable “Error Code”...
  • Page 85: Cr_Lamph Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.9.10 CR_LAMPH Command Command “CR_LAMPH” [CR] Get Lamp running time (in hours) Details * return actual lamp running time Acceptable “000_%1_%2_%3_%4” [CR] Lamp 1 data comes first, and then one space, after that lamp 2 data is followed.
  • Page 86: Setting Status Read Commands

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10 Setting Status Read Commands 9.10.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” ---------------------------- Italian is selected “ESP”...
  • Page 87: Cr_Pip Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.5 CR_PIP Command Command “CR_PIP” [CR] Details Get setting status of “Picture in Picture” Acceptable “000_%1” [CR] “OFF” -------------------- Off is selected “USER1” ---------------- User1 is selected “USER2” ---------------- User 2 is selected Response “USER3”...
  • Page 88: Cr_Pipmaininp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.8 CR_PIPMAININP Command Command “CR_PIPMAININP” [CR] Details Get Input and Source of “Picture in Picture”. (Main picture) Acceptable “000_%1_%2” [CR] “1” -------------------- Input1 is selected “2” -------------------- Input2 is selected “3” -------------------- Input3 is selected “4”...
  • Page 89: Cr_Pipsize Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.10 CR_PIPSIZE Command Command “CR_PIPSIZE” [CR] Details Get picture size of “Picture in Picture”. (Sub picture) Acceptable “000_%1_%2” [CR] “1” -------------------- 10% is selected(Main size) “2” -------------------- 20% is selected(Main size) “3” -------------------- 30% is selected(Main size) “4”...
  • Page 90: Cr_Blend Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.14 CR_BLEND Command Command “CR_BLEND” [CR] Details Get all values set for Width in Edge blending Acceptable “000_%1_%2_%3_%4” [CR] Left width data comes first, and then one space, after that right width data is followed. %1 = Left width %2 = Right width %3 = Top width...
  • Page 91: Cr_Blendtestpat Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.17 CR_BLENDTESTPAT Command Command “CR_BLENDTESTPAT” [CR] Details Get setting status of Test pattern of Edge blending Acceptable “000_%1” [CR] “ON” ---------------------- On is selected Response “OFF” --------------------- Off is selected Unacceptable “Error Code” [CR] 9.10.18 CR_COLORMATCHING Command Command “CR_COLORMATCHING”...
  • Page 92: Cr_Cmtgxy_%1 Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.21 CR_CMTGXY_%1 Command Command “CR_CMMTGXY_%1” [CR] Details Get “x””y” value of Target of Color matching Acceptable “000_%2” [CR] “RED” ---------------------- value of Red is selected “GREEN” ----------------- value of Green is selected “BLUE” -------------------- value of Blue is selected “WHITE”...
  • Page 93: Cr_Cmtgtestpat Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.25 CR_CMTGTESTPAT Command Command “CR_CMTGTESTPAT” [CR] Details Get setting status of Test pattern(Target) of Color matching Acceptable “000_%1” [CR] “RED” ---------------------- Red is displayed “GREEN” ----------------- Green is displayed “BLUE” -------------------- Blue is displayed “WHITE”...
  • Page 94: Cr_Rcode Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.30 CR_RCODE Command Command “CR_RCODE” [CR] Details Get currently selected Remote Control code Acceptable “000_%1” [CR] “001” -------------------------- Code1 “002” -------------------------- Code2 Response “007” -------------------------- Code7 “008” -------------------------- Code8 Unacceptable “?” [CR] 9.10.31 CR_RSENS Command Command “CR_RSENS”...
  • Page 95: Cr_Keydis Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.35 CR_KEYDIS Command Command “CR_KEYDIS” [CR] Details Get setting status of RC/KEY use limitation (valid or invalid) Acceptable “000_%1” [CR] “NONE” ------------------------- RC & KEY are valid Response “RC” ----------------------------- RC is invalid “KEY” --------------------------- KEY is invalid Unacceptable “?”...
  • Page 96: Cr_Shutkeyprot Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.40 CR_SHUTKEYPROT Command Command “CR_SHUTKEYPROT” [CR] Details Get status if Shutter can be controlled by key on the side panel Acceptable “000_%1” [CR] “ON” ----------- Shutter is not controllable by key on the side panel Response “OFF”...
  • Page 97: Cr_Ccaptionsidp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.45 CR_CCAPTIONSIDP Command Command “CR_CCAPTIONDISP” [CR] Details Get selected channel of Closed caption Acceptable “000_%1” [CR] “OFF” --------- Off “CC1” --------- CC1 is selected Response “CC2” --------- CC2 is selected “CC3” --------- CC3 is selected “CC4”...
  • Page 98: Cr_Filremain Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.50 CR_FILREMAIN Command Command “CR_FILREMAIN” [CR] Details Get the value of Filter counter remaining (remaining life time of the air filter) (%). Acceptable “000_%1” [CR] “100” = Filter counter remaining is 100% Response ÿ “000”...
  • Page 99: Cr_Ptime Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.10.55 CR_PTIME Command Command “CR_PTIME” [CR] Details Get setting time for count down mode of P-timer Acceptable “000_%a” [CR] Response “001” – “180” ----------------------- 1 to 180 minutes Unacceptable “Error Code” [CR] 9.10.56 CR_TESTPAT Command Command “CR_TESTPAT”...
  • Page 100: Other Status Read Commands

    PLC-HF15000L Expand Serial Command Functional Specifications 9.11 Other Status Read Commands 9.11.1 CR_STATUS Command Command “CR_STATUS” [CR] Get operating status of Projector Details Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
  • Page 101: Cr_Tempfail Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.11.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside the projector when the abnormal status occurs. Details It is possible to get the temperatures for more than one sensor all at once if it is applicable.
  • Page 102: Cr_Temp Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.11.6 CR_TEMP Command Command “CR_TEMP”[CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.
  • Page 103: Cr_Serialno Command

    PLC-HF15000L Expand Serial Command Functional Specifications 9.11.9 CR_SERIALNO Command Command “CR_SERIALNO” [CR] ÿ Details Get value of the serial number. For Dealerÿ Acceptable “000_%1” [CR] Response Eight digits of alphanumeric characters Unacceptable “?” [CR] 103/105...
  • Page 104: Command With Address Specification

    PLC-HF15000L Expand Serial Command Functional Specifications 10ÿ Command with Address Specification 10.1. Overview - Commands with address are used to remote control more than one projector through RS-232C by a computer. - The command with address is defined as a single command per line that starts with “A” and ends with carriage return (0x0D).
  • Page 105: When The Command Pipelining Is Needed

    PLC-HF15000L Expand Serial Command Functional Specifications 10.2.2. When the command pipelining is needed When it needs command pipelining, the operation is the same as the remote control as below: Sending-side system issues commands every 100ms When receiving an applicable command, the function is executed repeatedly for 120ms.