PRODUCT MODEL NUMBERS
WGD9050X, WGD9150W, WGD9151X,
WGD9250W, WGD9270X
:
Gas supply
This dryer is equipped for use with Natural
gas. Dryer can be converted to L.P. gas. When rigid
pipe is used it should be 1/2" IPS. When acceptable
to the gas supplier and local codes, 3/8" approved
tubing may be used for lengths under 20 ft (6.1 m).
For lengths over 20 ft (6.1 m), larger tubing should be
used. Pipe-joint compounds resistant to the action of
L.P. gas must be used. An individual manual shutoff
valve must be installed within 6 ft (1.8 m) of the dryer
in accordance with the National Fuel Gas Code ANSI
Z223.1.
Electrical
:
A 120-volt, 60 Hz, AC-only, 15 or 20 amp
fused electrical supply is required. A time-delay fuse or
circuit breaker and a separate circuit are recommended.
:
Water (Steam models only)
The dryer must be
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
Exhaust venting
:
Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
B
4"
(102 mm)
A
4"
A. Louvered hood
(102 mm)
B. Box hood
4"
C. Angled hood (acceptable)
(102 mm)
The vent system chart provides venting requirments
that will help to achieve the best drying performance.
Vent system chart:
NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum
exhaust length, add one 90° turn to the chart.
Number of
Type of
o
90 turns
vent
or elbows
0
Rigid metal
Rigid metal
1
2
Rigid metal
Rigid metal
3
Rigid metal
4
Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. Use the fewest 90° turns
possible.
Do not use vent runs longer than specified in vent length
chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
C
2½"
(64 mm)
Box or
Angled
Louvered
hoods
hoods
64 ft (20 m)
58 ft (17.7 m)
54 ft (16.5 m)
48 ft (14.6 m)
44 ft (13.4 m)
38 ft (11.6 m)
35 ft (10.7 m)
29 ft (8.8 m)
27 ft (8.2 m)
21 ft (6.4 m)

Gas Dryer

OVERALL DIMENSIONS
Dryer dimensions
27"
(686 mm)
/
35
3
"
8
(899 mm)
1"
(25 mm)
Front view
48
/
"
1
8
(1238 mm)
47
/
"
1
8
(1197 mm)
Door Open view
Cabinet and closet dimensions
For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
34" recommended
(76 mm)
(864 mm)
18" min.
(457 mm)
3"
4"
(102 mm)
(76 mm)
1"
(25 mm)
1"
(25 mm)
Closet (dryer only) installation
(140 mm)
Stacked washer and
dryer installation
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
29"
(736 mm)
Left or
right side
exhaust
/
3
1
"
2
(89 mm)
/
1
5
"
8
(41 mm)
/
6
7
"
8
(174 mm)
Side view
Custom under counter (dryer only)
installation
7"
(178 mm)
3"
48 in.
2
(310 cm
)
2
24 in.
2
(155 cm
)
2
4"
(102 mm)
6"
(152 mm)
3"
(76 mm)
76"
(1930 mm)
/
5
1
"
2
3"
(76 mm)
1"
1"
(25 mm)
(25 mm)
/
6
"
1
4
(159 mm)
Electric
/
28
1
"
8
(715 mm)
/
3
"
1
2
(89 mm)
14"
(358 mm)
Back view
39" min.
(990 mm)
1"
(25 mm)
1"
(25 mm)
18"
(460 mm)
1"
(25 mm)
1"
(25 mm)
Cabinet (dryer only) installation
48 in.
2
(310 cm
)
2
24 in.
2
(155 cm
)
2
Ref. W10240584C
12/2010

Advertisement

loading

This manual is also suitable for:

Wgd9150wWgd9151xWgd9250wWgd9270x