hit counter script
Download Print this page
Panasonic CZ-RWRD3 Operating Instructions Manual
Panasonic CZ-RWRD3 Operating Instructions Manual

Panasonic CZ-RWRD3 Operating Instructions Manual

High-spec wired remote controller

Advertisement

Quick Links

INDIVIDUAL CONTROLLERS
Design wired remote controller
Wired remote controller (for Floor Standing (P1) indoor units)
402
CZ-RTC5B
· Power consumption monitor (only for PACi)
· Flat face design & Touch sensor switch for stylish design and
operating usability
· New functions such as for Energy saving & monitoring and for
Service use are available on the Full dot LCD (3,5" display)
· Improved illumination
· White LED backlit
· Blink when alarm occurs
datanavi
· Scan & Save AC system info
· Easy access to manual database
· Commissioning, F gas check data history
* Panasonic App is required on your smartphone.
Basic Operation.
· Operation · Mode · Temperature setting · Airflow volume
· Airflow direction
CZ-RTC2
· Time Function 24 hours real time clock (week day indicator)
· Weekly programme function (a maximum of 6 actions can be
programmed for each day)
· Sleeping function (this function controls the room temperature
for comfortable sleeping)
· Maximum 8 indoor units can be controlled from one remote
controller
· Remote controller by main remote controller and sub controller is
possible (maximum 2 remote controllers (main remote controller
and sub controller) can be installed for one indoor unit)
Timer function.
· Outing function · Weekly Program timer · Easy ON/OFF timer
· Time display
Energy saving.
· Outing function · Temperature setting range limitation
· Temperature auto return · OFF remind · Schedule demand
control · Energy saving mode · Energy monitoring
Others.
· Key lock · Ventilation fan control · Display contrast adjustment
· Remote controller sensor · Quiet operation mode · Prohibit
setting control from Central controller · Rotation / Back up
control
* Power consumption monitoring is available for all PACi systems except R410A PACi
Standard.
* Rotation and backup control with CZ-RTC5B is available for all PACi systems.
· Possible to connect to the outdoor unit using PAW-MRC cable
for servicing purposes
· Outing function (this function can prevent the room temperature
from dropping or rising when the occupants are out for a long time)
Basic remote controller ON/OFF.
· Operation mode changeover (Cooling, Heating, Dry, Auto, Fan)
· Temperature setting (Cooling / Dry: 18-30°C Heating: 16-30°C)
· Fan speed setting High / Medium / Low and Auto
· Air flow direction adjustment
· Dimensions (H x W x D): 120 x 120 x 16mm

Advertisement

loading

Summary of Contents for Panasonic CZ-RWRD3

  • Page 1 Central controller · Rotation / Back up · Commissioning, F gas check data history control * Panasonic App is required on your smartphone. * Power consumption monitoring is available for all PACi systems except R410A PACi Standard.
  • Page 2 · When CZ-RWS3 is used, infrared control becomes possible for all indoor units (1: when a CZ-RWS3 + CZ-RWRD3 // CZ-RWS3 + CZ-RWRT3 // CZ-RWS3 + CZ-RWRC3 separate receiver is set up in a different room, control from that room also becomes ·...
  • Page 3 Ventilation Setting ............. 54 z Setting List ..............55 Before operating the unit, read these operating instructions thoroughly and z Troubleshooting............57 z Specifications ............59 keep them for future reference. Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan Panasonic Corporation http://www.panasonic.com CV6233312187...
  • Page 4 Safety Precautions WARNING CAUTION This symbol refers to a hazard or unsafe This symbol refers to a hazard or unsafe practice which can result in severe personal practice which can result in personal injury or injury or death. product or property damage. Matters to be observed Prohibited matters WARNING...
  • Page 5 Note: z This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. z This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 6 Thank you for purchasing the Panasonic high-spec wired remote controller. z Read the Operating Instructions carefully for safe use. This manual describes the Operating Instructions of the wired remote controller. Read this manual as well as operating instructions supplied with indoor units and outdoor units.
  • Page 7 Part Names Control panel Return button Menu button Returns to the previous screen. Displays the menu screen (P. 10). LCD screen Cross key buttons Selects an item. Left Right Down Operation indicator Illuminates during operation. Blinks during alarm. Energy saving Start/Stop button button Starts/Stops operation.
  • Page 8 Part Names Screen display Top screen Appears when ECONAVI is being datanavi Operation is Present time & set to ON. (ECONAVI settings outputting locked. (P.40) day (P.40) are possible only when fitted with (P.4) ECONAVI panel/ECONAVI sensor.) Setting Remote information controller icon name (P.41)
  • Page 9 z Setting information icon (Setting information icons displayed on the top screen) Icon Description Page The indoor unit filter needs to be cleaned. P.20 The engine oil needs to be replaced. (Only when using a gas heat pump air conditioner.) Switching operation mode is prohibited.
  • Page 10 Basic Operations Start operation. Press (The operation indicator illuminates.) „ To change the setting (P.10) „ To turn the energy saving operation ON/OFF Press during operation. (Only for models equipped with the energy saving function.) „ Start/Stop Operation indicator Select the item to set. Press ◄...
  • Page 11 Perform the following operations in step 2 on page 8. „ Operation mode (e.g. Cool, Heat, etc.) Press ◄. * Auto: Heat The mode is automatically Cool switched to Cool or Heat to achieve the set Auto temperature. „ Set temperature Press .
  • Page 12 Menu List Display the menu screen. „ To return to the previous screen Press „ When no operation is performed in each setting screen for several minutes The display returns to the top screen. Select the menu item. „ Selectable menus (1 to 16) ▲...
  • Page 13 „ Menu items (1 to 16) „ No. 10 [Energy saving] details The ECONAVI sensor Basic Explains the basic detects human activity ECONAVI P.24 instructions operations. and conserves energy based on the activity level. Restores the temperature Sets flaps for each indoor P.12 FLAP Temp auto...
  • Page 14 Flap Setting for Each Indoor Unit FLAP e.g. unit 1-1 e.g. unit 1-3 When setting flaps for each indoor unit • Flaps of all air outlets of 1 indoor unit face the same direction. Display the menu screen. „ To return to the previous screen Press „...
  • Page 15 Flap Setting for Each Air Outlet Lock individual flap (Lock indiv. flap) When setting the flap for each air outlet individually according to the room condition • Even if the flap setting of all indoor units (P.9) or each indoor unit (P.12) is changed, the flap directions set here are not changed.
  • Page 16 Timer Reservation ON/OFF timer This turns ON/OFF at the specified time. (e.g. Turning ON/OFF after 3 hours) Operation Operation 3 hours 3 hours stop stop • Use OFF timer for example when: Reducing electric consumption while sleeping • Use ON timer for example when: Operating the air conditioner according to the meeting start time.
  • Page 17 Timer Reservation Weekly timer overview You can set a weekly operation schedule. • The operation ON/OFF schedule or temperature setting schedule can be set by setting the day and time (e.g. Setting the operation start time to 8:00 a.m. from every Monday to Friday.).
  • Page 18 Timer Reservation Weekly timer New registration • e.g. Start operation with 26 °C at 10:00 a.m. on every Sunday. Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Weekly timer].
  • Page 19 Set the start time for the timer operation. hour minute ▲ ▼ → ► → ▲ ▼ → • 0:00 to 23:59 Select the timer operation. ▲ ▼ → • Types of timer operation z ON: Starts operation. z OFF: Stops operation. z ON &...
  • Page 20 Timer Reservation Weekly timer continued Change/Delete After steps 1 to 4 on page 16, select the day to change or delete. ◄ ► Select the schedule to change or delete. ▲ ▼ → Select [Change] or [Delete]. ▲ ▼ → Perform [Change] or [Delete] as follows.
  • Page 21 Timer Reservation Weekly timer continued The registered schedule can be copied to other days. Timer copy This is convenient to apply the same schedule to multiple days. Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times.
  • Page 22 Filter Information Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select the item to set. ▲ ▼ → Filter information Select [Next filter cleaning time]. ▲ ▼ → Confirm the operation time to the next cleaning.
  • Page 23 Note z If the function is not fitted, the display shown on the right appears and this function cannot be used. z When the cleaning time comes, the icon shown on the right appears on the top screen. (EN)
  • Page 24 Quiet Operation/Power Consumption Monitor Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select the item to set. ▲ ▼ → Quiet operation Enter the password. ▲ ▼ → ► → (Repeat) Set [Select enable/disable] to [ ].
  • Page 25 Power consumption monitor Select the period to display. ▲ ▼ → Confirm the information. (Press 2 times to finish.) • 1 day Power consumption (approx.) • 1 week Power consumption (approx.) • Pressing ◄► can switch data of 1-week total and data of each day.
  • Page 26 Energy Saving „ ECONAVI This function is available by attaching an optional ECONAVI sensor. The ECONAVI sensor detects human activity and conserves energy based on the activity level. WARNING Do not use the ECONAVI function in a room with disabled persons or infants only. Due to their limited motions, the ECONAVI sensor may judge no person is present, causing the indoor unit to stop the operation.
  • Page 27 Note z ECONAVI can be set using the separately sold ECONAVI panel or by connecting the holder on the wall. z Even when target temperature is changed through the ECONAVI function, the set temperature shown in the remote controller does not change. z Even when Cooling/Heating is changed to Fan through the ECONAVI function, the operation mode shown in the remote controller will still be Cooling/Heating.
  • Page 28 Energy Saving Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Energy saving]. ▲ ▼ → Select [ECONAVI]. ▲ ▼ → Select the item to set. ▲...
  • Page 29 Absence operation mode Select the item to set for when no one is in the room. ▲ ▼ → → (Press 2 times to finish.) z Types of the Absence operation mode Select the Absence operation mode from among the following 4 options on the remote control.
  • Page 30 Direct/Indirect airflow (Direct/Ind. airflow) When ECONAVI is off, select [Yes]. ◄ ► → Select [Setting for all units] or [Settings for individual units]. ▲ ▼ → Set. „ Setting for all units ▲ ▼ → → (Press 2 times to finish.) •...
  • Page 31 Circulation Only when ECONAVI is off, select [YES]. ◄ ► → Select [Setting for all units] or [Settings for individual units]. ▲ ▼ → Set. „ Setting for all units ▲ ▼ → → (Press 2 times to finish.) „ Settings for individual units ▲...
  • Page 32 Energy Saving „ Temp auto return Restoring the changed temperature to the originally set temperature automatically after a specified time elapses. (e.g. Only when a guest comes) „ Temp range Restricting the temperature range that can be set. (Temperatures outside the range cannot be set.) Display the menu screen.
  • Page 33 Temp range Select the item and set to [ ]. ▲ ▼ → ◄ ► → Set the temperature range. ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to finish.) Setting range • Cool/Dry: 18 °C to 30 °C •...
  • Page 34 Energy Saving „ Auto shutoff When the operation is stopped at a specified time (e.g. closing time) and resumed afterwards, this function detects the operation status at regular time intervals and stops operation automatically. Detect the operation status at regular time intervals and stop the operation automatically. (e.g.
  • Page 35 Stop time Time to stop operation (Time when Auto shutoff is activated) Set. hour minute ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to finish.) End time Time when Auto shutoff stops Set. hour minute ▲ ▼ → ► → ▲ ▼ → →...
  • Page 36 Energy Saving Time zone to reduce the operation capacity „ Schedule peak cut Large This reduces the operation capacity for the specified time period. Operation capacity Small 11:00 13:00 16:00 19:00 Display the menu screen. „ To return to the last screen Press „...
  • Page 37 Set the start time and end time. ▲ ▼ → ► → ▲ ▼ → (Repeat) Select the operation capacity. → ▲ ▼ → (Press 2 times to finish.) „ To set in series Repeat from step 4 without pressing „...
  • Page 38 Energy Saving (e.g. Setting to stop operation after 60 minutes) „ Repeat off timer 60 min Auto stop This stops operation after a certain period of time each time operation is performed. (e.g. When forgetting turning off) Turns on Finishes A/C.
  • Page 39 Internal Drying Settings Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Internal drying settings]. ▲ ▼ → Select [Setting for all units] or [Settings for individual units]. ▲...
  • Page 40 Outing Function This function prevents the room temperature from rising too high (or dropping too low) when no one is in the room due to outing, etc. • • • • • • (EN)
  • Page 41 Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Outing function] ▲ ▼ → Select [Select enable/disable] and set to [ ]. ▲ ▼ → ◄ ► → (Press 2 times to finish.) Select [Set lower/upper limit temp.].
  • Page 42 Initial Settings „ Clock „ Clock type „ Operation lock Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Initial settings]. ▲ ▼ → Select the item to set. ▲...
  • Page 43 Initial Settings „ Controller name The room to which the remote controller belongs can be easily identified. Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Initial settings]. ▲...
  • Page 44 Initial Settings „ Touch sound „ Contrast „ Backlight „ Language Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Initial settings]. ▲ ▼ → Select the item to set. ▲...
  • Page 45 Initial Settings „ Password change „ Temp sensor „ Main/sub „ Vent output „ Contact address Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Initial settings]. ▲...
  • Page 46 *To display each item, see steps 1 to 4 on the previous page. Temp sensor ▲ ▼ → → (Press 2 times to finish.) • Select the temperature sensor to Indoor unit Remote control the room temperature. controller Temp sensor Main/sub ▲...
  • Page 47 Initial Settings „ External device interlock Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Initial settings]. ▲ ▼ → Select the item to set. ▲ ▼ → Enter the password as necessary.
  • Page 48 Initial Settings „ External device interlock (Continued) Mode Select the item to set. ▲ ▼ → Set and confirm. ▲ ▼ → → (Press 2 times to finish.) „ Human activity YES/NO • Synchronizes the presence/absence output of the motion sensor. „...
  • Page 49 Initial Settings „ Rotation setting Rotation operation Equalizes the operation time by stopping the operation in order. This prevents the operation time from being uneven depending on the refrigerant system. System1 Operation Stand by Operation Stand by Operation System2 Stand by Operation Stand by Operation...
  • Page 50 Initial Settings „ Rotation setting (Continued) Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Initial settings]. ▲ ▼ → Select the item to set. ▲ ▼ → Enter the password.
  • Page 51 Backup Select the item to set. ▲ ▼ → set [Failure substitution]/ [Temperature support]/[Main system setting]. ▲ ▼ → „ Failure substitution When this is set to ON, a system in standby mode will perform the support operation in case of alarm occurrence. „...
  • Page 52 nanoe™ X Function „ nanoe™ X „ Internal cleaning Display during operation of nanoe™ X Under operation of nanoe™ X nanoe™ X For a freshness and cleaner environment nanoe™ X generates negative ions using the air in the room to give a healthy air.
  • Page 53 Internal Cleaning Function „ Internal Cleaning Operation When cooling or dry operation stopped, internal drying and nanoe™ X circulation airflow is activated in order to suppress the mold proliferation inside the unit (airflow passage, fan, heat exchanger). According to the installation environment or operating hours, mold proliferation or inhibition of mold growth will be changed.
  • Page 54 Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [nanoeX settings]. ▲ ▼ → nanoe™ X Select [nanoeX]. ▲ ▼ → Select [Setting for all units] or [Settings for individual units].
  • Page 55 Internal cleaning Select [Internal cleaning]. ▲ ▼ → Select [Setting for all units] or [Settings for individual units]. ▲ ▼ → Set. „ Setting for all units ▲ ▼ → → (Press 2 times to finish.) „ Settings for individual units ▲...
  • Page 56 Ventilation Setting Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Ventilation]. ▲ ▼ → Select [Ventilation ON/OFF]. Select [ON] or [OFF]. ▲ ▼ → → (Press 2 times to finish.) (EN)
  • Page 57 Setting List This provides the meanings of setting information icons. Display the menu screen. „ To return to the previous screen Press „ To return to the top screen Press 2 times. Select [Setting list]. ▲ ▼ → Select the item. ▲...
  • Page 58 Setting List „ Setting information icon list Icon Description Page [Lock indiv. flap] is set. P.13 Switching between Heat and Cool/Dry mode is prohibited (Switching to Auto – mode is also prohibited.). Remote control operation is restricted by a central control device. –...
  • Page 59 Troubleshooting If operation does not start by pressing Check the following before asking for repair. When the [START/ z Being centrally controlled, operation is not STOP is prohibited.] possible. message is displayed z After recovery from blackout, press again. Blackout? →If operation does not start, turn off the circuit breaker and consult the dealer of purchase about the symptom and Model No.
  • Page 60 Troubleshooting The remote z Faulty sensor or incorrect installation. →Turn OFF the ECONAVI function with the controller screen remote controller and contact the retailer or displays a flashing point of purchase with the Model No. and “ ”. problem. z The indoor unit has stopped. Turn on the indoor unit.
  • Page 61 Specifications Model No. CZ-RTC5B Dimensions (H) 120 mm x (W) 120 mm x (D) 16 mm Weight 180 g Temperature/ 0 ˚C to 40 ˚C / 20% to 80% (No condensation) Humidity range *Indoor use only. Power Source DC16 V (supplied from indoor unit) ±...
  • Page 62 © Panasonic Corporation 2018...
  • Page 63 Installation Instructions Separately Attached. Receiver OPERATION TIMER STANDBY • Use this unit with the receiver that is separately sold. English Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan...
  • Page 64 Safety Precautions WARNING CAUTION This symbol refers to a hazard This symbol refers to a hazard or unsafe practice which can or unsafe practice which can result in severe personal injury result in personal injury or or death. product or property damage. Matters to be observed Prohibited matters WARNING...
  • Page 65 CAUTION This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible...
  • Page 66 Operating Precautions ● Do not locate in the following types of places. • Where there is moisture, oil, or vibration/In direct sunlight/Near heat sources/ Where condensation forms (These can cause malfunctions.) • Where there is rapid start fluorescent lighting or inverter lights near the receiver (This can cause incorrect operation.) ● Do not clean with benzene or thinners or wipe with chemical cloths. (This can cause discolouration or malfunction.) • When the unit is very dirty, dampen a cloth in water or warm water, wring thoroughly, and wipe.
  • Page 67 Information for Users on Collection and Disposal of Old Equipment and Used Batteries These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
  • Page 68 Contents Safety Precautions ................2 Operating Precautions ................4 Supported Functions ................7 Names and Operations................8 Installing Batteries ................12 Setting the Current Time..............14 Using the Remote Controller ...............14 Paring Addresses ................16 Operation .....................18 Lock Individual Flap ................20 nanoe™ X Setting ................21 ECONAVI Setting ................22 Ventilation Setting ................23 Energy Saving Setting .................23 Temperature Automatic Return ............24...
  • Page 69 Supported Functions Available functions vary depending on the model of the indoor unit and the combination of the optional equipment. Also functions may vary even between indoor units of the same type if their capacities or manufactured years are different. See the operating instructions of the indoor unit for the settable functions.
  • Page 70 Names and Operations REMOTE CONTROLLER (EN)
  • Page 71 1 remote controller can control a group of up to 8 indoor units. (See page 28) 1. Operation Display 11. Temperature setting buttons Displays the operation status. raises the temperature (The figure shows all the setting 1 °C at a time. statuses.) lowers the temperature setting 1 °C at a time.
  • Page 72 Names and Operations (Cont.) Receiver CZ-RWRU3 CZ-RWSU2N CZ-RWRD3 CZ-RWRU3W CZ-RWSD2 CZ-RWSU3 CZ-RWRC3 CZ-RWRL3 CZ-RWSC3 CZ-RWSL2N Display Operation Panel CZ-RWRT3 Build-in receiver on indoor unit CZ-RWST3N (Wall mounted type / 4-Way Cassette 60 × 60 type) OPERATION TIMER STANDBY (EN)
  • Page 73 1. Receiver Screen display Receives the signal sent from the remote controller. 13 14 15 2. Emergency operation button See page 12. Indicator lamps When an error occurs, one of the lamps flashes. When an indicator lamp is flashing, refer to “Troubleshooting”. 3. OPERATION lamp Lights up when the unit is operating.
  • Page 74 Names and Operations (Cont.) Emergency operation Use [Emergency Operation] in the following situations when there is an urgent need. • When the remote controller’s batteries have failed. • When the remote controller is broken. • When the remote controller is lost. 1.
  • Page 75 2. Insert two LR03 size batteries. • Put the batteries in with the polarity [+/–] as shown in the figure. 3. Gently insert one end of an unfolded paper clip (or a similar object that can fit) into the RC reset hole and press the RC reset button inside the hole.
  • Page 76 Setting the Current Time 1. Press for 2 seconds or longer. • The time display flashes. (The colon lights up.) 2. Press to set the hour, then press 2, 3 3. Press to set the minutes, then press Note 2, 3 • If the buttons are not pressed for a certain duration while setting the time, the displayed time is set.
  • Page 77 Wall Mount Use ■ Mounting the holder 1. Fasten the remote control holder with Screws (supplied) screws. Remote control holder 2. Slide the remote controller down into the holder. • Press from the location you wish to mount the remote controller and make sure the signal is received properly.
  • Page 78 Paring Addresses When more than 1 indoor units are installed in the same room with a compatible remote controller, addresses can be set up to avoid crosstalk. You can control up to 6 indoor units individually by the supported remote controller by pairing the address on the remote controller and the number on the address switch on the receiver.
  • Page 79 2. Press to select the address of the receiver you want to control, and press • Every time you press , it cycles from “ALL (All the addresses) → 1 → 2 → 3 → 4 → 5 → 6”. • If it corresponds to the receiver’s address setting, the buzzer sounds. Note •...
  • Page 80 Operation Hold the remote controller with your hand and point its transmitter at the receiver. Power: Turn on the circuit breaker beforehand, referring to the operating instructions for the unit. 1. Press 2. Press to select the operation mode. • Every time you press , it cycles from “Auto → Heat...
  • Page 81 4. Press to set the temperature. MAX (°C) MIN (°C) Auto Heat / Cool • Temperature settings cannot be made in Fan mode. • The temperature range that can be set varies depending on the model. • The maximum temperature varies depending on the system and operating condition.
  • Page 82 Lock Individual Flap (Supported models: 4-way ceiling cassette type) You can set the flap for each air outlet individually according to the room condition. • Even if the flap setting is changed with (P.19), the flap directions set here are not changed. Flap Indoor unit 1. Press at the same time for 4 seconds or longer. • “ ” starts blinking and the setting screen is displayed. 2.
  • Page 83 4. Press to select the flap direction, then press • Every time you press , it cycles from “ (Unlock) ↔ (Swing) ↔ ↔ ↔ ↔ ↔ ”. 5. Press • You can return to Step 2 to continue setting if you press instead of Note •...
  • Page 84 ECONAVI Setting (ECONAVI can be set using the separately sold ECONAVI panel or by connecting the holder on the wall.) 1. Press during operation. ECONAVI • You can toggle between ON and OFF each time you press ECONAVI • “ ” is displayed when this setting is ON.
  • Page 85 Ventilation Setting (When connected to an aftermarket fan) button is disabled as the factory setting. Enable the button if you have connected the ventilation fan. (See page 30) 1. Press • You can toggle between ON and OFF each time you press •...
  • Page 86 Temperature Automatic Return You can restore the changed temperature to the originally set temperature automatically after a specified time elapses. • Set the time and temperature for each operation mode. Operation mode Temperature 1. Press at the same time for 4 seconds or longer. • “ ” starts blinking and the setting screen is displayed.
  • Page 87 Changing the setting Perform Step 1 to 5 (P. 24) as you did when setting. Cancelling the setting 1. Press at the same time for 4 seconds or longer. 2. Press to select the operation mode, then press 4 seconds or longer. •...
  • Page 88 Timer Operation • When setting the timer, make sure the current time on the remote controller is accurate. • The timer’s clock can only be set when the display of the remote controller is ON. • After setting the timer, put the remote controller for in a place where its signal will reach the receiver of the indoor unit.
  • Page 89 Combining ON and OFF Timers 1. The ON and OFF timers can be set respectively. Checking the timer setting 1. Press • The scheduled time is displayed for 4 seconds. • When the timer is not set or after replacing batteries, it displays “...
  • Page 90 Operating Multiple In/Outdoor Units Simultaneously (Group control) Group control works well for providing air Outdoor unit conditioning to 1 large room with more than 1 air conditioning units. • 1 remote controller can operate up to 8 indoor Receiver Indoor unit units.
  • Page 91 < How to Operate > • While holding down the buttons below, the remote controller’s display changes every time is pressed. • Whatever is being displayed when you release is set. Remote Controller Setting Item Operation Button Setting Content Display Heat Pump (with Auto) Remote controller...
  • Page 92 Button Control You can enable or disable the following buttons for some indoor units. nanoe™ X, ECONAVI, Ventilation, Energy saving 1. Press the button for desired setting for 4 seconds or longer. • You can toggle between enable and disable each time you press the button for 4 seconds or longer.
  • Page 93 Troubleshooting Before requesting service, please check the following. Problem Cause Solution The unit doesn’t work The power to the indoor unit is not Make sure the power to the indoor unit is ON. even when pressed on the remote Are the remote controller’s Change the batteries.
  • Page 94 100 g (Batteries and remote controller holder are not Weight included) Temperature/ 0 ˚C to 40 ˚C / 20% to 80% (No condensation) Humidity range *Indoor use only. Power source Two LR03 size batteries Clock Accuracy ±90 seconds per month (at 25 °C) Panasonic Corporation http://www.panasonic.com © Panasonic Corporation 2018 - 2019...