Ideal Clima MACH + User's And Installer's Manual

Heat recovery units with high efficiency

Advertisement

Quick Links

HEAT RECOVERY UNITS
WITH HIGH EFFICIENCY
MACH +
18
U
S
E
R
A
N
D
I
N
S
T
A
L
L
E
R
M
A
N
U
A
L
U
S
E
R
A
N
D
I
N
S
T
A
L
L
E
R
M
A
N
U
A
L

Advertisement

Table of Contents
loading

Summary of Contents for Ideal Clima MACH +

  • Page 1 HEAT RECOVERY UNITS WITH HIGH EFFICIENCY MACH +...
  • Page 2: Table Of Contents

    SIPHON - CONDENSATE DRAIN ........................15 8.11 ELECTRICAL CONNECTION ........................16 8.12 CALIBRATION OF FAN FLOW RATES ......................18 8.13 START-UP AND TESTING ..........................18 WARRANTY CONDITIONS ........................19 10 NOTE................................ 19 1 FOREWORD © Ideal Clima-Page 2 / 20...
  • Page 3: Liability

    These rules are also intended for the operator already specifically instructed to operate this type of unit and contain all the information necessary and essential for the safety of operation and optimal use of the unit. © Ideal Clima-page 3 of 20...
  • Page 4: Operations And Maintenance

    - after cleaning the unit, the operator must check that there are no worn or damaged parts or not securely fixed, otherwise ask the maintenance technician for help; © Ideal Clima-Page 4 / 20...
  • Page 5: Intended Use

    The installation of IDEAL CLIMA heat recovery units with very high efficiency, allows to easily achieve energy consumption appropriate to Class A, with proportional increase in the value of the property.
  • Page 6: Model

    (about N. B. The indicator light resets 4000 hours). automatically with the cleaning N. B. The warning light resets of the filters. after pressing the reset button for 10 seconds 2.3.5 ANTIFREEZE THERMOSTAT © Ideal Clima-Page 6 / 20...
  • Page 7: Operational Limits

    The electrical panel for external connection is equipped with light switch, fuse and power socket. MACH+ with manual free-cooling MACH+ with automatic free-cooling © Ideal Clima-page 7 of 20...
  • Page 8: Electric Schemes

    MACH+ heat recovery units— User and installer manual ELECTRIC SCHEMES Ground connection is mandatory. The installer must connect the ground cable. MACH + is powered at 230V 50 Hz single-phase. 4.2.1 MACH+ WIRING WITH MANUAL FREE-COOLING © Ideal Clima-Page 8 / 20...
  • Page 9 MACH+ heat recovery units— User and installer manual 4.2.2 MACH+ WIRING WITH AUTOMATIC FREE-COOLING © Ideal Clima-page 9 of 20...
  • Page 10: Technical Data

    MACH+ 510 vertical marking certifies compliance with the standards: Machinery Directive (2006/42/EEC); Low Voltage Directive (2014/30/EU); Electromagnetic compatibility (2014/35/EU; RoHS (2011/65/EU; ErP 2016 Regulation and 2018 (1253/14/EU E1254/14/EU; EN12100 of 2010; EN60204-1 of 2016 © Ideal Clima-Page 10 / 20...
  • Page 11: After Sale

    - construction site residues clog - clean pan the collection pan ROUTINE MAINTENANCE Disconnect the unit from the mains, open the machine and do the following: Cleaning filters (2 times a year): © Ideal Clima-page 11 of 20...
  • Page 12: Decommissioning Of The Unit

    Is a good rule to keep them separately and deliver them to the disposal or possible recycling, the companies responsible for the purpose, and to reduce so the impact on the environment. © Ideal Clima-Page 12 / 20...
  • Page 13: Positioning

    Open all hinges, with the utmost care to avoid the fall of the internal components as well as the door itself. Perform the planned operations inside. Close the door, with hinges, so that it fits perfectly on the recovery unit, leaving no air passages. Apply safety screws PREDISPOSITION FOR CONDENSATE DRAIN CONNECTION © Ideal Clima-page 13 of 20...
  • Page 14: Ceiling Horizontal Recovery Unit Assembly

    The connections of supply and extract from the premises, as well as expulsion and renewal to the outside, are shown in the © Ideal Clima-Page 14 / 20...
  • Page 15: Siphon - Condensate Drain

    In order not to transmit vibration to the entire system, the first section must be made with flexible pipes. Ideal Clima's TREO distribution system adapts perfectly to the use of MACH+ recovery units. 8.10 SIPHON - CONDENSATE DRAIN...
  • Page 16: Electrical Connection

    (the differential pressure switch returns to the rest position) Supply Line: Insert the VDE power plug into the connector next to the ignition switch, on the electrical connection panel. Cable and plug are supplied. © Ideal Clima-Page 16 / 20...
  • Page 17 The reset button is a standard electrical button (not supplied), to be connected according to wiring diagram. Supply Line: Insert the VDE power plug into the connector next to the ignition switch, on the electrical connection panel. Cable and plug are supplied. © Ideal Clima-page 17 of 20...
  • Page 18: Calibration Of Fan Flow Rates

    The test must be carried out by qualified personnel and adequately trained also for subsequent maintenance. © Ideal Clima-Page 18 / 20...
  • Page 19: Warranty Conditions

    MACH+ heat recovery units— User and installer manual 9 WARRANTY CONDITIONS The warranty of this product is governed by the general conditions of sale Ideal Clima (version 3.0) of which the part relating to the warranty: Ideal Clima guarantees its products for defects or manufacturing defects, with the express exclusion of any defect or fact inherent in the installation, conduct and maintenance of the product.
  • Page 20 Tel. +39.030.35.45.319-Fax +39 030.51.09.329 info@idealclima.eu – www.idealclima.eu Version 4.0 October 2020 In a process of constant improvement, the company reserves the right to make changes to the product at any time, even without notice. © Ideal Clima-Page 20 / 20...