EQUIPMENT
FUNCTIONAL
NAME
PN-8LCAD
LC
PN-8LCAE
LC
[For China]
PN-4LDTA
LDT
PN-4LLCB
LLC
Line/Trunk Card Name and Function
NAME
8-line Analog Line Circuit Card for Single Line Telephones
Provides Caller ID Display on analog station.
Loop resistance: Maximum 600 Ω (including telephone set)
Provides Message Waiting Lamp control, momentary open for
each circuit.
8-line Analog Line Circuit Card for Single Line Telephones
Provides Caller ID Display on analog station.
Loop resistance: Maximum 600 Ω (including telephone set)
Provides Message Waiting Lamp control, momentary open for
each circuit.
4-line Loop Dial Trunk Card
Loop resistance: Maximum 3000 Ω (including internal resistance
of the distant office equipment)
PN-PW03 is required.
4-line Analog Long Line Circuit Card for Single Line Telephones
Provides Caller ID Display on analog station.
Loop resistance for PB/DP type:
PB
DP (20 PPS): Maximum 1700 Ω
DP (10 PPS): Maximum 2500 Ω
Including the internal resistance of the distant office equipment
Provides Message Waiting Lamp control, momentary open/
reverse functions for each circuit.
PN-PW03 is required.
CHAPTER 1 GENERAL INFORMATION
FUNCTION
: Maximum 1200 Ω
– 41 –
EQUIPMENT NAME AND FUNCTION
Continued on next page
NWA-008842-001 Rev.3.0
JANUARY/31/2006
3sch1001.fm