Installation
33
Test run
Loosen the pressure measuring tap screw (2) 1/4 of a turn.
Connect a manometer to the measuring tap.
Select a program that uses heat.
Start the dryer.
Check the nozzle pressure, see table.
If necessary adjust the regulator setting screw (4) found behind cover
screw (3). Replace cover screw (3) if removed.
Check that the gas is burning evenly and with a bluish flame.
After testing, prepare the dryer for use.
Gasvalve
1. Nozzle
2. Measuring branch, nozzle pressure
3. Adjusting screw cap
4. Adjusting screw
5. Ignition control
6. Measuring tap, supply pressure
5
6
2
3 + 4
1