Panasonic S-15MK2E5B Operating Instructions Manual
Panasonic S-15MK2E5B Operating Instructions Manual

Panasonic S-15MK2E5B Operating Instructions Manual

Hide thumbs Also See for S-15MK2E5B:

Advertisement

Wall Mounted
(Type K2)
* Shows type 45, 56, 73, 106
Model No.
INDOOR UNIT
Wall Mounted
(Type K2)
S-15MK2E5B
S-45MK2E5B
S-22MK2E5B
S-56MK2E5B
S-28MK2E5B
S-73MK2E5B
S-36MK2E5B
S-106MK2E5B
● Connectable outdoor unit lineup
OUTDOOR UNIT
Refrigerant type : R410A
mini VRF (Type LE1, LE2)
2WAY VRF (Type ME2)
3WAY VRF (Type MF3)
Refrigerant type : R32
mini VRF (Type LZ2)
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
Operating Instructions
Air Conditioner
WEB-ACXF55-29100-EN

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-15MK2E5B

  • Page 1 ENGLISH * Shows type 45, 56, 73, 106 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Model No. INDOOR UNIT Wall Mounted (Type K2) S-15MK2E5B S-45MK2E5B S-22MK2E5B S-56MK2E5B S-28MK2E5B S-73MK2E5B S-36MK2E5B S-106MK2E5B ● Connectable outdoor unit lineup...
  • Page 2: Table Of Contents

    Safety Precautions Thank you for purchasing this Panasonic product. This product is a commercial air conditioner indoor unit. Installation Instructions attached. Contents The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or...
  • Page 3 WARNING If the refrigerant comes in contact Do not use modified with a flame, it produces a toxic cord, joint cord, gas. extension cord or unspecified cord to prevent For safety, be sure to turn the overheating and fire. air conditioner off and also to disconnect the power before cleaning or servicing.
  • Page 4 WARNING Do not sit or step on the unit. The appliance shall be stored You may fall down accidentally. in a room without continuously operating open flames (for example: an operating gas If refrigerant R32 is used and appliance) and ignition sources R32 refrigerant leakage detection (for example: an operating electric sensor is connected to the indoor...
  • Page 5 WARNING CAUTION This appliance is intended to be used If the alarm display J01 appears, by expert or trained users in shops, there is something wrong R32 in light industry and on farms, or for refrigerant leakage detection commercial use by lay persons. sensor or its wiring connection to This appliance can be used by the indoor unit.
  • Page 6: Precautions For Use

    Precautions for Use Installation Information for Users on Collection and Disposal of Old Equipment and Used Batteries This air conditioner must be installed properly by qualified installation technicians in accordance with the Installation hese symbols on the products, packaging, Instructions provided with the unit. and/or accompanying documents mean that Before installation, check that the voltage of the electric used electrical and electronic products and...
  • Page 7: Names Of Parts

    Names of Parts INDOOR UNIT Type 15, 22, 28, 36 Type 45, 56, 73, 106 Air fi lters Air fi lters Front panel Front panel Receiver Vertical airfl ow direction louver Vertical airfl ow direction louver • Do not adjust by hand •...
  • Page 8: Maintenance

    Maintenance Maintenance WARNING CAUTION For safety, be sure to turn the air conditioner off and Never use solvents or harsh chemicals. Also, do not wipe disconnect the power before cleaning. (Otherwise, plastic parts using very hot water. electric shock or injury may result because the fan is (This may cause deformation or change in colour.) rotating at high speed.) Some metal edges and fins are sharp.
  • Page 9: Operation Mechanism

    „ Cleaning „ After Cleaning Cleaning instructions : 1. After the air filter is cleaned, reinstall it in its original position. • Do not use benzene, thinner or scouring powder. Be sure to reinstall in reverse order. • Use only soap ( pH7) or neutral household detergent.
  • Page 10: Troubleshooting

    Troubleshooting Check before consulting or requesting services. Symptom Cause / Action Sound like streaming water is heard • Sound of refrigerant liquid flowing inside unit during operation or after operation. • Sound of drainage water through drain pipe Noise Cracking noise is heard during operation •...
  • Page 11: Before Requesting Services

    Symptom Cause / Action No operation (When the power is turned on immediately / • Operation is not activated for the first approx. 3 minutes When operation is stopped and resumed because the compressor protection circuit is activated. immediately) Noise occurs during heating operation. •...
  • Page 12 Connectable outdoor unit lineup Europe „ Refrigerant type : R410A Outdoor unit type 4 HP 5 HP 6 HP 8 HP 10 HP 1-phase U-4LE2E5 U-5LE2E5 U-6LE2E5 – – 3-phase U-4LE2E8 U-5LE2E8 U-6LE2E8 – – 3-phase – – – U-8LE1E8 U-10LE1E8 3-phase –...
  • Page 13: Specifications

    Specifications Indoor unit Wall Mounted Model Name S-15MK2E5B S-22MK2E5B S-28MK2E5B S-36MK2E5B S-45MK2E5B S-56MK2E5B Power source 220 - 230 - 240 V~ 50 - 60 Hz Cooling capacity 5,100 7,500 9,600 12,300 15,400 19,100 BTU/h Sensible Latent Heating capacity 5,800 8,500...
  • Page 14: Outdoor Unit

    Specifications Outdoor unit mini VRF (Type LZ2) Model Name U-4LZ2E5 U-5LZ2E5 U-6LZ2E5 Power source 220 - 230 - 240 V~ 50 Hz Cooling capacity 12.1 14.0 15.5 Heating capacity 12.5 16.0 16.5 Sound pressure level 52 / 54 53 / 56 54 / 56 dB(A) (Cooling / Heating)
  • Page 15 Model Name U-8LZ2E8 U-10LZ2E8 Power source 380 - 400 - 415 V 3N~ 50 Hz 22.4 28.0 Cooling capacity 76,500 95,600 BTU/h 25.0 28.0 Heating capacity 85,300 95,600 BTU/h Sound pressure level dB(A) Sound power level dB(A) Unit dimensions (H×W×D) 1,500×980×370 1,500×980×370 Net weight...